- Nagano, Japón
HIGH VOLTAGE MULTIPLEXER SW2001
Input channels: 2 channels of high-voltage, 2-terminal input: insulation and withstanding voltage tester input, impulse winding tester input 2 channels of low-voltage, 4-terminal input: LCR meter input, resistan...
Nagano, JapónAC/DC CURRENT SENSOR CT7822
rated measurement current: 20 A AC/DC | Max. allowable input: 30 A rms continuous (±43 Ap) | Bandwidth: DC to 100 kHz | Basic accuracy: DC± 0.3% rdg. ±0.1% f.s. | Core diameter: φ 5 mm or less | Output connector...
Nagano, JapónAC/DC CURRENT SENSOR CT7812
Rated measurement current: 2 A AC/DC | Max. allowable input: 3 A rms continuous (±4.3 Ap) | Bandwidth: DC to 100 kHz | Basic accuracy: DC± 0.3% rdg. ±0.1% f.s. | Core diameter: φ 5 mm or less | Output connectors:...
Nagano, JapónAC/DC AUTO-ZERO CURRENT SENSOR CT7742
Rated measurement current: 2000 A AC/DC | Max. measurement current: 2000 A (requires derating at frequency) | Max. allowable peak input: 2840 A peak | Bandwidth: DC to 5 kHz (-3dB) (When used in combination with...
Nagano, JapónAC/DC CURRENT SENSOR CT7642
Rated measurement current: 2000 A AC/DC | Max. measurement current: 2000 A (requires derating at frequency)) | Max. allowable peak input: 2840 A peak | Bandwidth: DC to 10 kHz (-3dB) (When used in combination wi...
Nagano, JapónAC/DC CURRENT SENSOR CT7631
Rated measurement current: 100 A AC/DC | Max. measurement current: 100 A (requires derating at frequency)) | Max. allowable peak input: 150 A peak | Bandwidth: DC to 10 kHz (-3dB) (When used in combination with ...
Nagano, JapónAC/DC AUTO-ZERO CURRENT SENSOR CT7736
Rated measurement current: 600 A AC/DC | Max. measurement current: 600 A (requires derating at frequency) | Max. allowable peak input: 900 A peak | Bandwidth: DC to 5 kHz (-3dB) (When used in combination with CM...
Nagano, JapónDISPLAY UNIT CM7290
Sensor: CT7642, 7742 | Measurement parameters: DC, AC, DC+AC, Hz | Crest factor: 3 at 5000 count or 2.5 at 6000 count for AC and DC+AC | Output method: WAVE, RMS, PEAK, FREQ | Input connectors: HIOKI PL 14 | Outp...
Nagano, JapónAC FLEXIBLE CURRENT SENSOR CT7040 series
Rated measurement current: 6000 A AC | Internal measurement range: 600A AC/ 6000A AC (Range is controlled by main device) | Max. allowable input: 10000 A continuous (at 6000 A range, 45 to 66 Hz, requires deratin...
Nagano, JapónCLAMP ON LEAK SENSOR 9675
Rated primary current: AC 10 A (for leak current measurement, 50/60 Hz) | Max. allowable input (45-66 hz): Max. 10 A of continuous input | Rated output current: AC 100 mV/A | Amplitude accuracy (45-66 hz): ±1.0...
Nagano, JapónCLAMP ON SENSOR 9695-03
Rated measurement current: 100 A AC | Max. measurement current: Continuous 130 A (45 to 66 Hz) | Output rate: 1 mV AC/ A | Amplitude accuracy (45 to 66 hz): ±0.3 % rdg. ±0.02 % f.s. (*1) | Phase accuracy: ±1° (...
Nagano, JapónCLAMP ON SENSOR 9669
Rated measurement current: 1000 A AC | Max. measurement current: Continuous 1000 A (45 to 66 Hz) | Output rate: 0.5 mV AC/ A | Amplitude accuracy (45 to 66 hz): ±1.0% rdg. ±0.01% f.s. | Phase accuracy: ±1° (45 ...
Nagano, JapónCLAMP ON SENSOR 9660
Rated measurement current: 100 A AC | Max. measurement current: Continuous 130 A (45 to 66 Hz) | Output rate: 1 mV AC/ A | Amplitude accuracy (45 to 66 hz): ±0.3 % rdg. ±0.02 % f.s. | Phase accuracy: ±1° (45 Hz...
Nagano, JapónHEAT FLOW LOGGER LR8432
Specialized functions for heat flow measurement: - Easy scaling settings: directly enter the sensitivity of the heat flow sensor - Calculations: waveform processing function for the analysis of temperature and he...
Nagano, Japón