Building Filters
Yamato IN804
- Fabricante: Yamato
- Modelo: IN804
System: Forced air convection | Operating temperature range: -10~50℃ | Temperature adjustment accuracy: ±0.3℃(when refrigerator is in continuous operation), ±1.0℃(when refrigerator is in cycle operation) | Temper...
Tokio, JapónYamato IN604W
- Fabricante: Yamato
System: Forced air convection | Operating temperature range: -10~50℃ | Temperature adjustment accuracy: ±0.3℃(when refrigerator is in continuous operation), ±1.0℃(when refrigerator is in cycle operation) | Temper...
Tokio, JapónYamato INC820
- Fabricante: Yamato
System (upper chamber): Natural convection, Air jacket | Operating temp. range(upper chamber): Room temp.+5℃~80℃ | Temp. adjustment accuracy (upper chamber): ±0.5℃(at 37℃) | Temp. distribution accuracy (upper cha...
Tokio, JapónCLAMP ON SENSOR 9669
Rated measurement current: 1000 A AC | Max. measurement current: Continuous 1000 A (45 to 66 Hz) | Output rate: 0.5 mV AC/ A | Amplitude accuracy (45 to 66 hz): ±1.0% rdg. ±0.01% f.s. | Phase accuracy: ±1° (45 ...
Nagano, JapónUV500 IMO
Sample flow: Recommended : 0 – 5 L/min | Sample pressure: 0 – 4 Bar (0 - 1 Bar with sampling peristaltic pump) | Sample temperature: 0 °C to 80 °C 0 to 80 °C for NH4 or H2S | Wet parts material: Quartz, Polypropy...
Kioto, JapónHORIBA Advanced Techno Co., Ltd. K-11
- Fabricante: Horiba
Measurement principle: Ion Selective Electrode | Minimum sample volume: 0.3ml (0.05ml with sampling sheet B) | Measurement range: 4 to 9900 ppm (mg/L) 0.1 to 250 mmol/L 2 to 5000 kg/10a | Resolution: 0 to 99...
Kioto, JapónEARTH TESTER FT6041
- Fabricante: HIOKI E.E
measurement parameters: • Ground resistance measurement: 4-pole method, 3-pole method, 2-pole method, MEC function, clamp-on measurement (two clamps) • Soil resistivity measurement: 4-pole method • Low-resistanc...
Nagano, JapónCARD HiTESTER 3244-60
Dc voltage range: 419.9 mV to 500 V, 5 ranges, Basic accuracy: ±0.7 % rdg. ±4 dgt. | Ac voltage range: 4.199 V to 500 V, 4 ranges, Basic accuracy 50 - 500 Hz : ±2.3 % rdg. ±8 dgt. (Average rectified) | Resistanc...
Nagano, JapónCLAMP ON SENSOR 9695-02
Rated measurement current: 50 A AC | Max. measurement current: Continuous 60 A (45 to 66 Hz) | Output rate: 10 mV AC/ A | Amplitude accuracy (45 to 66 hz): ±0.3 % rdg. ±0.02 % f.s. (*1) | Phase accuracy: ±2° (4...
Nagano, JapónHORIBA Advanced Techno Co., Ltd. HE-480C
- Fabricante: Horiba
Product name: Industrial conductivity meter | Measurement method: Electrode type (2-electrode method) | Cell constant: 0.01/cm, 0.1/cm, or 1.0/cm | Temperature sensor specifications: Platinum resistance 1000 Ω/0℃...
Kioto, JapónHORIBA Advanced Techno Co., Ltd. HP-480
- Fabricante: Horiba
Product name: Industrial pH meter | Measuring range: 0 pH to 14 pH: 0.01 pH resolution. Temperature 0℃ to 100℃: 1℃ resolution (selectable display). | Transmission output: 4 mA to 20 mA DC: input/output isolated t...
Kioto, JapónCLAMP ON SENSOR 9695-03
Rated measurement current: 100 A AC | Max. measurement current: Continuous 130 A (45 to 66 Hz) | Output rate: 1 mV AC/ A | Amplitude accuracy (45 to 66 hz): ±0.3 % rdg. ±0.02 % f.s. (*1) | Phase accuracy: ±1° (...
Nagano, JapónCLAMP ON PROBE 9132-50
Rated current: 20 A to 1000 A AC, 6 ranges | Accuracy: ±3 % rdg. ±0.2 % f.s. (45 to 66 Hz) | Frequency characteristics: Add to amplitude accuracy for frequencies from 40 to 1 kHz: ± 1 % rdg. | Output rate: 0.2 V ...
Nagano, JapónHORIBA Advanced Techno Co., Ltd. Salt-22
- Fabricante: Horiba
Measurement principle: Ion Selective Electrode | Minimum sample volume: 0.3ml (0.05ml with sampling sheet B) | Salinity range: 0.01 to 25% by weight | Resolution: 0.00 to 0.99%: 0.01% 1.0 to 9.9%: 0.1% 10 to...
Kioto, JapónANALOG MΩ HiTESTER IR4016
- Fabricante: HIOKI E.E
Rated output voltage: 500 V DC | Effective maximum indicated value: 100 MΩ | Accuracy 1st effective measuring range: ±2 % of scale length, 0.1 M to 50 MΩ | Lower limit resistance: 0.5 MΩ (measurement resistance v...