Building Filters
RESISTANCE METER RM3548-50
Resistance range: 3 mΩ (3.5000 mΩ display Max., 0.1 µΩ resolution) to 3 MΩ range (3.5000 MΩ display Max., 100 Ω resolution), 10 steps Measurement accuracy: ±0.020 % rdg. ±0.007 % f.s. | Testing current: [at 3 mΩ ...
Nagano, JapónHORIBA Advanced Techno Co., Ltd. HR-480
- Fabricante: Horiba
Product name: Industrial Residual Chlorine Meter | Measurement method: Galvanic cell method | Repeatability: Within ±0.05 mg/L (with equivalent input) | Linearity: Within ±0.05 mg/L (with equivalent input) | Tran...
Kioto, JapónAC FLEXIBLE CURRENT SENSOR CT9667
Rated input current: 5000 A AC/ 500 A AC | Max. allowable input: 10000 A continuous (45 to 66 Hz, requires derating at frequency) | Bandwidth: 10 Hz to 20 kHz (±3dB) | Amplitude and phase accuracy: ±2 % rdg. ±0.3...
Nagano, JapónHORIBA Advanced Techno Co., Ltd. LAQUAtwin EC-33
- Fabricante: Horiba
Measurement principle: 2 Electrode Bipolar AC | Minimum sample volume: 0.12ml | Display: Custom (monochrome) LCD with backlight | Operating temperature: 5 to 40°C | Operating humidity: 85% or less relative humidi...
Kioto, JapónLCR METER IM3523A
Measurement modes: LCR (Measurement with single condition), Continuous testing (Continuous measurement under saved conditions) | Measurement parameters: Z, Y, θ, X, G, B, Q, Rdc (DC resistance), Rs (ESR), Rp, Ls,...
Nagano, JapónYamato ILE800
- Fabricante: Yamato
Circulation method: Natural convection by air jacket | Operating temperature range: 0 to +60℃ | Temp. control accuracy: ±0.2℃ (when refrigerator is in the continuous operation) ±0.3℃ (when refrigerator is in the ...
Tokio, JapónINSULATION TESTER IR4059
- Fabricante: HIOKI E.E
Rated output voltage: 50 V DC | Effective maximum indicated value: 100 MΩ | Accuracy 1st effective measuring range mω: ±2 % rdg. ±2 dgt. 0.200 - 10.00 | Lower limit resistance: 0.05 MΩ | Overload protection: 600...
Nagano, JapónHORIBA Advanced Techno Co., Ltd. HD-480
- Fabricante: Horiba
Product name: Dissolved oxygen meter | Measurement method: Galvanic cell method | Measuring range: Dissolved oxygen 0 mg/L to 20 mg/L, 0.01 mg/L resolution Saturation 0% to 200%, 1% resolution Temperature 0℃ to 4...
Kioto, JapónCLAMP ON LEAK SENSOR 9657-10
Rated primary current: AC 10 A (for leak current measurement, 50/60 Hz) | Max. allowable input (45-66 hz): Max. 30 A of continuous input | Rated output current: AC 100 mV/A | Amplitude accuracy (45-66 hz): ±1.0...
Nagano, JapónCLAMP ON LEAK SENSOR 9675
Rated primary current: AC 10 A (for leak current measurement, 50/60 Hz) | Max. allowable input (45-66 hz): Max. 10 A of continuous input | Rated output current: AC 100 mV/A | Amplitude accuracy (45-66 hz): ±1.0...
Nagano, JapónCLAMP ON SENSOR 9661
Rated measurement current: 500 A AC | Max. measurement current: Continuous 550 A (45 to 66 Hz) | Output rate: 1 mV AC/ A | Amplitude accuracy (45 to 66 hz): ±0.3% rdg. ±0.01% f.s. | Phase accuracy: ±0.5° (45 Hz...
Nagano, JapónYamato IN604
- Fabricante: Yamato
System: Forced air convection | Operating temperature range: -10~50℃ | Temperature adjustment accuracy: ±0.3℃(when refrigerator is in continuous operation), ±1.0℃(when refrigerator is in cycle operation) | Temper...
Tokio, JapónYamato IQ822
- Fabricante: Yamato
System: Forced Convection | Operating temperature range: -10~+50℃ | Temperature adjustment accuracy: ±0.3℃(During continuous refrigeration for both upper and lower chamber) | Temperature distribution accoracy: ±1...
Tokio, JapónCLAMP ON SENSOR 9694
Rated measurement current: 5 A AC | Max. measurement current: Continuous 50 A (45 to 66 Hz) | Output rate: 10 mV AC/ A | Amplitude accuracy (45 to 66 hz): ±0.3 % rdg. ±0.02 % f.s. | Phase accuracy: ±2° (45 Hz t...
Nagano, JapónCLAMP ON SENSOR 9660
Rated measurement current: 100 A AC | Max. measurement current: Continuous 130 A (45 to 66 Hz) | Output rate: 1 mV AC/ A | Amplitude accuracy (45 to 66 hz): ±0.3 % rdg. ±0.02 % f.s. | Phase accuracy: ±1° (45 Hz...
Nagano, Japón