MEMORY HiLOGGER LR8450 en Nagano, Japón

Especificaciones

Condición
nuevo
Max. number of connectable modules
4 plug-in modules
Connectable modules (plug-in modules)
See [Options] > [Plug-in modules]
No. of measurement channels
Up to 120 ch with plug-in modules. U8555 can input up to 500 channels per unit.
Pulse/logic input
[Number of ch] 8 ch (common GND, non-isolated, exclusive setting for pulse/logic input for individual channels) [Adaptive input format] Non-voltage contact, open collector, or voltage input [Count] 0 to 1000 M pulse, 1 pulse resolution [Rotational speed] 0 to 5000/n (r/s), 1/n (r/s) resolution, 0 to 300,000/n (r/min.), 1/n (r/min.) resolution, n: Number of pulses per rotation (1 to 1000) [Logic input] Records 1 or 0 for each recording interval
Recording intervals
1 ms*, 2 ms*, 5 ms* (*: Can be set only when using 1 ms/S modules), 10 ms to 1 hour, 22 selections (Data refresh interval can be set for each unit
Data storage
SD Memory Card/USB Drive (user-selectable) (Only storage media sold by HIOKI are guaranteed for operation)
Lan interface
100BASE-TX / 1000BASE-T, DHCP, DNS support, Functions: Data acquisition, condition settings used with the Logger Utility software, configuring settings and controlling recording using communications commands, FTP server / FTP client, HTTP server, Email transmission, NTP client
Usb interface
Series A receptacle × 2: USB 2.0 compliant (USB drive, keyboard, or hub) Series mini-B receptacle × 1: Data acquisition, condition settings used with the Logger Utility, configuring settings and controlling recording using communications commands, transferring data from a connected SD Memory Card to a computer
Sd card slot
SD standard-compliant slot × 1 (with SD memory card/SDHC memory card support), Guaranteed-operation options: ‌Z4001, Z4003
Display
7 inch TFT color liquid crystal display (WVGA 800 × 480 pixel)
Functions
Save waveform data in real time to the SD memory card or USB drive, numerical value calculations, waveform calculations, 8ch alarm output, voltage output ×2 (5 V /12 V /24 V selectable)
Power supply
[AC adapter] Using the Z1014 (100 to 240 V AC, 50/60 Hz), 95 VA Max. (including AC adapter), 28 VA Max. (exclusive of AC adapter) [Battery Pack] Using the Z1007 (accommodates 2 batteries), continuous use 4 hr (reference value for 2 pieces), 20 VA Max. [External power] 10 to 30 V DC, 28 VA Max.
Dimensions and mass
Without any modules: 272 mm (10.71 in) W × 145 mm (5.71 in) H × 43 mm (1.69 in) D (excluding protrusions), 1108 g (39.1 oz) (excluding battery pack) With 2 modules: 272 mm (10.71 in) W × 198 mm (7.80 in) H × 63 mm (2.48 in) D (excluding protrusions) With 4 modules: 272 mm (10.71 in) W × 252 mm (9.92 in) H × 63 mm (2.48 in) D (excluding protrusions)
Included accessories
Quick Start Manual ×1, LOGGER Application Disc (Quick Start Manual, Instruction Manual, Logger Utility, Logger Utility Instruction Manual, CAN editor, CAN editor instruction manual, Communication Instruction Manual) ×1, USB Cable ×1, AC Adapter Z1014 ×1
ID de Anuncio
61137831

Descripción

Hioki Memory HiLoggers are high-speed data loggers for recording multiple channels of voltage, temperature, resistance or humidity signals, some models providing complete isolation between channels and strong noise resistance.
The LR8450 offers a sampling speed of up to 1 ms and up to 120 channels, depending on the types of plug-in modules that are selected. The modules measure strain and distortion, ideal for automotive applications involving the evaluation of vehicle components as well as robotic equipment.
Web Manual
Expandable to 120 ch with wired/plug-in modules
Record voltage output from pressure and other sensors with 1ms sampling speed

Directly connect strain gauge and measure signals in as fast as 1ms intervals
Significantly reduced effects from noise let you safely measure in high voltage and high frequency areas such as around inverter motors