HORIBA Advanced Techno Co., Ltd. CS-900
- Fabricante: Horiba
Model name: Non-contact type chemical concentration monitor | Measurement method: Absorption spectroscopy | Concentration calculation: Temperature compensated multivariate analysis | Conditions of measurement: 1)...
Kioto, JapónHORIBA Advanced Techno Co., Ltd. CS-100F1 Series
- Fabricante: Horiba
Measurement principle: Absorption spectrometry | Concentration computation principle: Temperature-compensated multivariate analysis | Sample solution temperature: 20 to 80: (when using Inline cell) 20 to 30: (whe...
Kioto, JapónHORIBA Advanced Techno Co., Ltd. CS-600F
- Fabricante: Horiba
Measurement principle: Absorption spectroscopic method | Calculation principle: Temperature compensation type multivariate analysis | Measurement target: NH 3 /H 2 O 2 /H 2 O (reperesentative specification) * Ple...
Kioto, JapónFlying Spot Scanner 310
Valores medidos: Espesor, distancia | Tasa de medición: Hasta 70.000 Hz | Rango de medición: Depende del sensor CHRocodile 2 IT | Resolución lateral: 20 µm (CHRocodile 2 IT DW) | Distancia de trabajo: 150 mm | Ve...
Gaggenau, AlemaniaFlying Spot Scanner
Measurements/second: up to 70 kHz | Measuring range: depends on selected CHRocodile 2 IT sensor | Scan area: 40 mm | Working distance: 125 mm | Max. speed measuring spot: 5 m/s
Gaggenau, AlemaniaHORIBA Advanced Techno Co., Ltd. HC-200NH
- Fabricante: Horiba
Combination sensor unit model: DO-2000 | Sensor model: 5700A: Sensor cap | Measurement range: Dissolved oxygen concentration: 0~20mg/L Display resolution 0.01mg/L Saturation degree: 0~200% Display res...
Kioto, JapónHORIBA Advanced Techno Co., Ltd. HR-480
- Fabricante: Horiba
Product name: Industrial Residual Chlorine Meter | Measurement method: Galvanic cell method | Repeatability: Within ±0.05 mg/L (with equivalent input) | Linearity: Within ±0.05 mg/L (with equivalent input) | Tran...
Kioto, JapónHORIBA Advanced Techno Co., Ltd. HC-200NH
- Fabricante: Horiba
Combination sensor unit model: DO-2000 | Sensor model: 5700A: Sensor cap | Measurement range: Dissolved oxygen concentration: 0~20mg/L Display resolution 0.01mg/L Saturation degree: 0~200% Display res...
Kioto, JapónHORIBA Advanced Techno Co., Ltd. HR-480
- Fabricante: Horiba
Product name: Industrial Residual Chlorine Meter | Measurement method: Galvanic cell method | Repeatability: Within ±0.05 mg/L (with equivalent input) | Linearity: Within ±0.05 mg/L (with equivalent input) | Tran...
Kioto, JapónHORIBA Advanced Techno Co., Ltd. HC-200F
- Fabricante: Horiba
Product name: Fluoride ion meter | Electrode used with product: Fluoride ion electrode | Temperature: 0.1℃ | Linearity: Within ±0.08 mA (output only) | Output type: Contact output with voltage (output of connecte...
Kioto, JapónDensity meter - continuous measurement of pulp density in the flow
- Fabricante: Dredgers of Ukraine
• monthly: density sampling and, if necessary, density correction (5-10 minutes). | • once every two months: flushing, visual inspection of the bypass (20 min). | • after six months of operation: dismantling and ...
Jersón, UcraniaHigh Res. Handheld Hyperspectral Imager
- Fabricante: Optosky (Xiamen) Photonics
Xiamen, ChinaSynchronous Thermal Analysis Equipment
Dsc: fusión, cristalización, cambio de fase, temperatura de reacción y calor de reacción, calor de combustión, calor específico... | Tg: estabilidad térmica, descomposición, oxidación-reducción, adsorción y desor...
Shanghái, ChinaSynchronous Thermal Analysis Instrument
Dsc: fusión, cristalización, cambio de fase, temperatura de reacción y calor de reacción, calor de combustión, calor específico... | Tg: estabilidad térmica, descomposición, oxidación-reducción, adsorción y desor...
Shanghái, ChinaTGA Thermal Analyzer
Jh-tga550: Parámetros técnicos | Rango de temperaturas: Temperatura ambiente ~ 1400℃ | Resolución de la temperatura: 0.1℃ | Fluctuación de la temperatura: ±0.1℃ | Tasa de calentamiento: 1~80℃/min | Método de cont...
Shanghái, China