Building Filters
HORIBA, Ltd. 51 series
- Fabricante: Horiba
Measuring principle: Non-Dispersive Infrared Absorption Method (NDIR) | Component: CO, CO 2 , CH 4 , etc. *1 | Span ±0.5% of full scale: Span : ±1.0% of full scale | Linearity: ±1.0% of full scale | Optional ran...
Kioto, JapónHORIBA Advanced Techno Co., Ltd. HD-480
- Fabricante: Horiba
Product name: Dissolved oxygen meter | Measurement method: Galvanic cell method | Measuring range: Dissolved oxygen 0 mg/L to 20 mg/L, 0.01 mg/L resolution Saturation 0% to 200%, 1% resolution Temperature 0℃ to 4...
Kioto, JapónHORIBA, Ltd. GI-700
- Fabricante: Horiba
Indicated error (linearity): ± 1.0 % of full-scale value for each component and range (Standard range ratio) ± 2.0 % of full-scale value for each component and range (Optinonal range ratio) | Zero drift: ± 1.0%/w...
Kioto, JapónHORIBA Advanced Techno Co., Ltd. CODA-500
- Fabricante: Horiba
Object: COD concentration in water | Dimensions: 600 (W) mm × 510 (D) mm × 1600 (H) mm* 1 | Mass: Approx. 150 kg | Power source: 100 V to 240 V AC ±10%, 50 Hz/60 Hz | Power consumption: 100 V to 120 V AC: Approx....
Kioto, JapónHORIBA Advanced Techno Co., Ltd. HE-960HI
- Fabricante: Horiba
Product name: Conductivity meter | Measuring method: Four-electrode type | Cell constant: 0.1/cm | Temperature sensor specifications: Resistance thermometer bulb 1000 Ω/0℃ | Temperature: −30℃ to 160℃ | Naoh: 0% t...
Kioto, JapónHORIBA Advanced Techno Co., Ltd. HE-480C
- Fabricante: Horiba
Product name: Industrial conductivity meter | Measurement method: Electrode type (2-electrode method) | Cell constant: 0.01/cm, 0.1/cm, or 1.0/cm | Temperature sensor specifications: Platinum resistance 1000 Ω/0℃...
Kioto, JapónHORIBA Advanced Techno Co., Ltd. HE-960HC
- Fabricante: Horiba
Measurement range: 0 - 1000mS/cm | Wetted materials: GC, Karletz, PFA | Sensor input: 1 ch | Repeatability: +/- 0.5% of the full scale (in equivalent input) | Linearity: +/- 0.5% of the full scale (in equivalent ...
Kioto, JapónHORIBA, Ltd. ENDA-5000
- Fabricante: Horiba
Repeatability: Within 0.5% of full scale/week (with optional range, or during O 2 measurement, ±1.0% of full scale/week) | Linearity (indicator error): ±1.0% of full scale | Zero drift: ±1.0% of full scale/week (...
Kioto, JapónPS-300S
- Fabricante: Horiba
Measurement principle: NDIR: Non-Dispersive Infrared | Linearity: ±2% full scale | Zero drift: ±2% full scale per day | Span drift: ±2% full scale per day | Sample gas flow rate: Max. 0.5 L/min | Display: 5.7-inc...
Kioto, JapónHORIBA Advanced Techno Co., Ltd. HE-480H
- Fabricante: Horiba
Product name: Industrial conductivity meter | Measurement method: Electrode type (4-electrode method) | Cell constant: 1.0/cm | Seawater salinity conversion value (%): 0.00 to 4.00 | Nacl salinity conversion valu...
Kioto, JapónHORIBA Advanced Techno Co., Ltd. Salt-11
- Fabricante: Horiba
Measurement principle: 2 Electrode Bipolar AC | Minimum sample volume: 0.12ml | Salinity range & resolution: 0.0 to 100.0 g/L (ppt): 0.1 g/L 0.00 to 10.00%: 0.01% | Calibration points: Up to 2 | Calibration curve...
Kioto, JapónHORIBA Advanced Techno Co., Ltd. OPSA-150
- Fabricante: Horiba
Product name: Organic Pollutant Monitor (UV meter) | Measurement item: UV absorbance, VIS absorbance, COD conversion concentration, TURB (turbidity) conversion concentration | Measurement principle: Dual optical ...
Kioto, JapónHORIBA, Ltd. PG-300 series
- Fabricante: Horiba
Nox: 0-25/50/100/250/500/1000/2500 ppm | So2 ,co, ch4: Cross-Modulation Non-Dispersive Infrared Absorption Method | O2: 0-5/10/25 vol% (Zirconia Method, or Galvanic Method) 0-10/25 vol% (Paramagnetic Method (Dum...
Kioto, JapónHORIBA Advanced Techno Co., Ltd. TPNA-500
- Fabricante: Horiba
Dimensions *1: 460 (W) mm × 385 (D) mm × 1600 (H) mm | Mass: Approx. 87 kg | Power supply: 100 V to 240 V AC ±10%, 50 Hz/60 Hz | Power consumption: 100 V to 240 V AC: Approx. 250 VA | Repeatability: Within ±3% of...
Kioto, JapónPTFM-ONE-DT
- Fabricante: HORIBA UK Limited
900°c exhaust gas limit: Allows the freedom to test engines under extreme conditions without worrying if the flow meter can handle those temperatures | -1.25kpa to +7.5kpa sensor range: Shows both positive flow &...