Building Filters
HORIBA Scientific nanoGPS OxyO Scale
- Fabricante: Horiba
Scales for microscopy on the horiba store: Scales for machine vision on the HORIBA Store:
Kioto, JapónHORIBA, Ltd. ENDA-7000 Series
- Fabricante: Horiba
This product is available in the following countries and territories: United States | Repeatability: ±0.5% full-scale ±0.1% full-scale (optional range) | Zero drift: ±1.0% full-scale per week ±2.0% ...
Kioto, JapónTCA-5000
Measurement principle: Thermal conductivity detection method | Measurement range: (Min.) 0 - 10 vol% (Max.) 0 - 100 vol% | Measurement range (optional): 0 - 5 vol% to less than 10 vol% 100 - 90 vol...
Kioto, JapónHORIBA, Ltd. APSA-380
- Fabricante: Horiba
Component: Sulfur dioxide (SO 2 ) | Measuring principle: Ultraviolet Fluorescence | Measurement range: 0-0.05/0.1/0.2/0.5/1.0/5.0/10/20 ppm (up to 8 ranges selectable, auto-range) *1 | Lower detection limit (2σ):...
Kioto, JapónHORIBA, Ltd. APHA-380
- Fabricante: Horiba
Component: Methane, non-methane hydrocarbons, total hydrocarbons (CH 4 , NMHC, THC) | Measuring principle: Flame lonization Detector Method (FID) with Selective Combustion | Measurement range: 0-5/10/20/50/100 pp...
Kioto, JapónHORIBA, Ltd. APMA-380
- Fabricante: Horiba
Component: Carbon monoxide (CO) | Measuring principle: Cross-Modulation Non-Dispersive Infrared Absorption (NDIR) | Measurement range: 0-5/10/20/50/100/300 ppm (up to 6 ranges selectable, auto-range) | Lower dete...
Kioto, JapónHORIBA, Ltd. APOA-380
- Fabricante: Horiba
Component: Ozone (O 3 ) | Measuring principle: Cross-Modulation Non-Dispersive Ultraviolet Absorption (NDUV) | Measurement range: 0 - 0.1 / 0.2 / 0.5 / 1.0 / 2.0 / 5.0 / 10 ppm *1 (up to 7 ranges selectable,...
Kioto, JapónHORIBA, Ltd. APNA-380
- Fabricante: Horiba
Component: Nitrogen oxides (NO, NO 2 , NOx) | Measuring principle: Cross-Modulation Chemiluminescence | Measurement range: 0-0.1/0.2/0.5/1.0/2.0/5.0/10/20 ppm (up to 8 ranges selectable, auto-range) | Lower detec...
Kioto, JapónHORIBA Advanced Techno Co., Ltd. HE-480C-GC
- Fabricante: Horiba
Repeatability: *1 Within +/- 0.5% of the full scale *2 Within +/- 1.0% of the full scale
Kioto, JapónPTFM-1000V2
- Fabricante: HORIBA UK Limited
Test vehicle/engine: Diesel (HDD, LDD), Gasoline, LPG and CNG vehicles, Ethanol, Propane, Butane | Configuration: Interface unit connected to pitot tube via umbilical cable. Pitot tube can be standard (0 - 230ºC)...
Kioto, JapónMEXA-1170SX
- Fabricante: HORIBA, Ltd.
Components: SO 2 , TRS * , Both SO 2 and TRS simultaneously and Total-S * Total reduced sulfur | Principle: Ultra-viiolet fluorescence | Sample gas flow rate: SO 2 , TRS Approx. 5 l/min | Linearity: SO 2 , SUM, T...
Kioto, JapónHORIBA Advanced Techno Co., Ltd. HF-700A
- Fabricante: Horiba
Model name: HF-700A | Measurement method: Fluoride ion electrode method | Measurement range: 0 - 1000mg/L (0 - 100/200/500/1000mg/L) | Repeatability: Within +/- 2% of the full scale | Stability: Within +/- 2% of ...
Kioto, JapónHORIBA Advanced Techno Co., Ltd. HE-480R
- Fabricante: Horiba
Product name: industrial resistance meter | Measurement method: Electrode type (2-electrode method) | Cell constant: 0.01/cm | Temperature sensor specifications: Platinum resistance 1000 Ω/0℃ | Repeatability: Wit...
Kioto, JapónHORIBA Advanced Techno Co., Ltd. HZ-960HPO-M
- Fabricante: Horiba
Chemical contact material of detector: PFA, PTFE, quartz glass | Supply pressure: Within 0.5 MPa | Repeatability: +/- 0.2% of full scale | Linearity: +/- 1.0% of full scale | Transmission output: Number of output...
Kioto, JapónHORIBA Advanced Techno Co., Ltd. HZ-960
- Fabricante: Horiba
Chemical contact material of detector: PFA, PTFE, quartz glass | Supply pressure: Within 0.5 MPa | Repeatability: +/- 0.2% of full scale | Linearity: +/- 1.0% of full scale | Transmission output: Number of output...
Kioto, Japón