Building Filters

Questron Technologies Corp QPrep
- Fabricante: Questron Technologies Corp
Kioto, Japón
HORIBA, Ltd. PX-375
- Fabricante: Horiba
Product name: Continuous Particulate Monitor with X-ray Fluorescence | Measured object: Particulate matter of black color | Measurement content: Particulate mass concentration and element concentration | Flow rat...
Kioto, Japón
Questron Technologies Corp QBlock Series
- Fabricante: Questron Technologies Corp
Kioto, Japón
HORIBA STEC, Co., Ltd. PV Series
- Fabricante: Horiba
Flow range: 10/20 LM | Flow control range: 2 -100% F.S. | Valve type: normally open / close | Input signal: 0 - 5VDC | Responce: less than 0.5 sec. | Operating temperature: 0 - 50 °C | Operating diffential pressu...
Kioto, Japón
PTFM-ONE-DT
- Fabricante: HORIBA UK Limited
900°c exhaust gas limit: Allows the freedom to test engines under extreme conditions without worrying if the flow meter can handle those temperatures | -1.25kpa to +7.5kpa sensor range: Shows both positive flow &...
Kioto, Japón
PTFM-1000V2
- Fabricante: HORIBA UK Limited
Test vehicle/engine: Diesel (HDD, LDD), Gasoline, LPG and CNG vehicles, Ethanol, Propane, Butane | Configuration: Interface unit connected to pitot tube via umbilical cable. Pitot tube can be standard (0 - 230ºC)...
Kioto, Japón
HORIBA, Ltd. Process
- Fabricante: Horiba
Kioto, Japón
HORIBA Scientific PPD Photon Counting Detector
- Fabricante: Horiba
Transit time spread: <180 ps typical at 405nm | Dimensions: 77 x 107 x 48 mm | Weight: 0.6 kg
Kioto, Japón
HORIBA Scientific PoliSpectra® VS70 Dual & Quad
- Fabricante: Horiba
Feature: Spectroscopy Benefits for OEMs 2-4 channel multi-spectral instruments | Most popular uv-vis-nir range: Excellent peak symmetry in a miniature grating spectrometer | High readout speed: Sub 1.5msec readou...
Kioto, Japón
HORIBA Scientific PowerArc
- Fabricante: Horiba
Input (user selectable): 105–120 V/60 Hz or 210–240 V/50 Hz | Power rating: 0 to 150 watts | Operating voltage: 10 to 24 volts | Operating current: 0 to 8 amps | Pre-ignition voltage: > 85 volts | Ripple at ma...
Kioto, Japón
HORIBA Scientific PoliSpectra® Quad
- Fabricante: Horiba
Spectral coverage: Tunable from 470 to 730 nm | Spectrometer input: FC (standard), other input types available upon request | Spectral resolution: 2.7 nm with 75 µm slit; 5 nm for Ø 200 µm fiber (no slit) |...
Kioto, Japón
HORIBA Scientific PoliSpectra® M116 MultiTrack Spectrometer
- Fabricante: Horiba
Spectral coverage: 185 - 1050 nm (configurable based on customer’s need) | Spectrometer input: 16 channel, φ100 μm core fibers with φ110 μm clad 32 channel, φ70 μm core fibers with φ77 μm clad | Spectral resoluti...
Kioto, Japón
HORIBA Advanced Techno Co., Ltd. 5800
- Fabricante: Horiba
Product name: Peracetic acid sensor ※3 | Temperature compensation element: Platinum resistance thermometer (Pt1000) 1000 W at 0℃, 3850 ppm/℃ | Measurement range: 100 to 4000ppm (0.010 to 0.400%) | Repeatability: ...
Kioto, Japón
PLGA-1000
Name: Process Laser Gas Analyzer | Measurement principle: NDIR: Non Dispersive Infrared | Light source: QCL: Quantum Cascade Laser | Laser class: Class 1(IEC 60825-1:2014) | Components*¹: Methane (CH 4 ), Ethane ...
Kioto, Japón
PH-SE
- Fabricante: Horiba
Kioto, Japón
