Building Filters

HORIBA Scientific OES-Star
- Fabricante: Horiba
Spectral coverage: 185 – 1050 nm (2048 horizontal pixel format with 14 µm pixel size) 200 – 1050 nm (2048 horizontal pixel format with 12 µm pixel size) | Spectrometer input: SMA (standard), other input types ava...
Kioto, Japón
HORIBA Advanced Techno Co., Ltd. OCMA-555-H
- Fabricante: Horiba
Kioto, Japón
Kioto, Japón
Kioto, Japón
HORIBA Advanced Techno Co., Ltd. OCMA-500
- Fabricante: Horiba
Product name: Oil content analyzer | Measurement method: Solvent extraction - non-dispersive infrared absorption analysis method | Measured objects: Substances extracted from sample water into solvent and having ...
Kioto, Japón
HORIBA Advanced Techno Co., Ltd. OCMA-550
- Fabricante: Horiba
Product name: Oil content analyzer | Measurement method: Solvent extraction - non-dispersive infrared absorption analysis method | Measured objects: Substances extracted from sample water into solvent and having ...
Kioto, Japón
OBS-ONE SPN10 Unit
- Fabricante: HORIBA, Ltd.
Measuring principles: Condensation particle counter (CPC) | Particle diameter: 10 ~ 1,000 nm | Measuring range: 0 ~ 5 × 10 7 particles/cm 3 | Power supply: DC 24 V | Power consumption (max.): Approx. 0.50 kW...
Kioto, Japón
OBS-ONE PN Unit
- Fabricante: HORIBA, Ltd.
Measuring principles: Condensation particle counter (CPC) | Particle diameter: 23 ~ 1,000 nm | Measuring range: 0 ~ 5 × 10 7 particles/cm 3 | Power supply: DC 24 V | Power consumption (max.): Approx. 0.25 kW...
Kioto, Japón
OBS-ONE-XL (IRLAM)
- Fabricante: HORIBA, Ltd.
Measurement target: Light and heavy duty vehicle engine exhaust gas | Components and range: NH 3 0 - 1500 ppm N 2 O 0 - 1000 ppm | Measurement principle: Quantum cascade laser infrared spectroscopy (QCL-IR) | Sam...
Kioto, Japón
OBS-ONE PM unit
- Fabricante: HORIBA, Ltd.
Measuring principles: Batch sampling: Filter gravimetric method Real-time PM measurement : Diffusion charging method | Measuring ranges (real-time pm sensor): 0 to 2500 mm/cm 3 (Concentration after dilution) | Di...
Kioto, Japón
OBS-ONE GS Unit
- Fabricante: HORIBA, Ltd.
Power requirements: DC 22〜28 V | Operating conditions: Temperature: -10 to 40 deg.C, *6 Relative humidity: less than 80%, Altitude: 0 to 2000 m above sea level | Standard signal measurements: Exhaust temperature,...
Kioto, Japón
HORIBA, Ltd. SZ-100-Z2 and SZ-100-HZ2 (with zeta potential measurement unit)
- Fabricante: Horiba
Measurement principles: Particle size measurement: Dynamic Light Scattering Molecular weight measurement: Debye plot method (static scattered light intensity) | Measurement range: -500 to +500 mV | Maximum sample...
Kioto, Japón
HORIBA Scientific Nanolog
- Fabricante: Horiba
Excitation sources: Choice of: 450 W xenon short-arc lamp housing with off axis ellipsoidal collector and optional pulsed xenon lamp enhancement (for time resolved phosphorescence) 75 W xenon PowerArcTM lamp...
Kioto, Japón
HORIBA Scientific nanoGPS OxyO Scale
- Fabricante: Horiba
Scales for microscopy on the horiba store: Scales for machine vision on the HORIBA Store:
Kioto, Japón
HORIBA Scientific nanoGPS OxyO Encoder
- Fabricante: Horiba
Kioto, Japón