HIGH VOLTAGE MULTIPLEXER SW2001
Input channels: 2 channels of high-voltage, 2-terminal input: insulation and withstanding voltage tester input, impulse winding tester input 2 channels of low-voltage, 4-terminal input: LCR meter input, resistan...
Nagano, JapónAC/DC CURRENT SENSOR CT7822
rated measurement current: 20 A AC/DC | Max. allowable input: 30 A rms continuous (±43 Ap) | Bandwidth: DC to 100 kHz | Basic accuracy: DC± 0.3% rdg. ±0.1% f.s. | Core diameter: φ 5 mm or less | Output connector...
Nagano, JapónAC/DC CURRENT SENSOR CT7812
Rated measurement current: 2 A AC/DC | Max. allowable input: 3 A rms continuous (±4.3 Ap) | Bandwidth: DC to 100 kHz | Basic accuracy: DC± 0.3% rdg. ±0.1% f.s. | Core diameter: φ 5 mm or less | Output connectors:...
Nagano, Japón- Nagano, Japón
DATA ANALYSIS SOFTWARE UA1801
License contents: License key (USB) only *Note: Please purchase computer, display and other hardware separately and download the installer and documentation from Hioki’s website. | Supported test equipment: FA181...
Nagano, JapónFIT-LINE INSPECTION DATA CREATION SYSTEM UA1780
Included: Installation CD, license key (USB), instruction manual (× 1 each) *Caution: Computer, monitor, and other hardware not included. | Gerber data input functions: Loading of Gerber files (RS-274X, RS-274D),...
Nagano, JapónAC/DC CURRENT SENSOR CT6862-05
Rated current: 50 A AC/DC | Max. allowable input: Within the derating range, up to ±150 A peak (design value) allowed at 40°C or less for 20 ms or less | Frequency bandwidth: Amplitude: DC to 10 MHz Phase: DC to ...
Nagano, JapónAC/DC AUTO-ZERO CURRENT SENSOR CT7731
Rated measurement current: 100 A AC/DC | Max. measurement current: 100 A (requires derating at frequency) | Max. allowable peak input: 150 A peak | Bandwidth: DC to 5 kHz (-3dB) (When used in combination with CM...
Nagano, JapónCLAMP ON LEAK SENSOR 9657-10
Rated primary current: AC 10 A (for leak current measurement, 50/60 Hz) | Max. allowable input (45-66 hz): Max. 30 A of continuous input | Rated output current: AC 100 mV/A | Amplitude accuracy (45-66 hz): ±1.0...
Nagano, JapónCLAMP ON SENSOR 9694
Rated measurement current: 5 A AC | Max. measurement current: Continuous 50 A (45 to 66 Hz) | Output rate: 10 mV AC/ A | Amplitude accuracy (45 to 66 hz): ±0.3 % rdg. ±0.02 % f.s. | Phase accuracy: ±2° (45 Hz t...
Nagano, JapónSAFETY TEST DATA MANAGEMENT SOFTWARE 9267
Compatible models: ST5520*, ST5540/ST5541, 3153, 3154, 3156, 3157, 3158, 3159, 3174, 3332, 3333, 3334, and PLCs from various manufacturers (for connection switching) *Control of the ST5520 is subject to certain l...
Nagano, JapónLEAK CURRENT HiTESTER ST5541
Measurement methods: Measurement of voltage drop across body simulated resistance points, Calculation and display of current values, True rms measurement, Measurement unit floats relative to instrument ground. ...
Nagano, JapónFlexPro
Productos hioki compatibles: MR6000, MR6000-01, MR8827, MR8740, MR8741, MR8847 (MR8847-01, MR8847-02, MR8847-03), MR8847A (MR8847-51, MR8847-52, MR8847-53), MR8875, LR8450, LR8432, LR8431, LR8410, LR8400, 8423, e...
Nagano, JapónLAN COMMUNICATOR 9333
Supported units: - Model MR8847-51/-52/-53, MR8827 (Ver.1.00 or later) - Model MR8740 (Ver.3.12 or later), MR8741 (Ver.2.12 or later), MR8847-01/-02/-03, 8847 (Ver.3.07 or later), 8826 (Ver.2.30 or later) - Model...
Nagano, JapónAC/DC AUTO-ZERO CURRENT SENSOR CT7742
Rated measurement current: 2000 A AC/DC | Max. measurement current: 2000 A (requires derating at frequency) | Max. allowable peak input: 2840 A peak | Bandwidth: DC to 5 kHz (-3dB) (When used in combination with...
Nagano, Japón