Building Filters

HORIBA Advanced Techno Co., Ltd. HP-480
- Fabricante: Horiba
Product name: Industrial pH meter | Measuring range: 0 pH to 14 pH: 0.01 pH resolution. Temperature 0℃ to 100℃: 1℃ resolution (selectable display). | Transmission output: 4 mA to 20 mA DC: input/output isolated t...
Kioto, Japón
Yamato CFW611
- Fabricante: Yamato
Method: External closed circulation | Operating temperature range: -10 to +80°C | Temperature control accuracy: ±0.1°C JTM K05 (at 20°C) | Temperature setting, display: Digital setting and display | Temperature i...
Tokio, Japón
Yamato DNF601
- Fabricante: Yamato
Method: 2 in 1 type: Forced and Natural convection, with manual exhaust damper | Heater: 0.83 kW×2 | Exhaust port: 50mm I.D. (Back)×1pc. | Additional functions: Heater operation amount, Power failure recovery mod...
Tokio, Japón
Yamato DNF411
- Fabricante: Yamato
Method: 2 in 1 type: Forced and Natural convection, with manual exhaust damper | Heater: 0.6 kW×2 | Exhaust port: 50mm I.D. (Back)×1pc. | Additional functions: Heater operation amount, Power failure recovery mode...
Tokio, Japón
Yamato CFA302
- Fabricante: Yamato
Method: External closed circulation | Operating temperature range: -10 to +60°C | Temperature control accuracy: ±0.1°C JTM K05 (at 20°C) | Temperature setting, display: Digital setting and display | Temperature i...
Tokio, Japón
Yamato DNF611
- Fabricante: Yamato
Method: 2 in 1 type: Forced and Natural convection, with manual exhaust damper | Heater: 0.83 kW×2 | Exhaust port: 50mm I.D. (Back)×1pc. | Additional functions: Heater operation amount, Power failure recovery mod...
Tokio, Japón
Yamato DNF401
- Fabricante: Yamato
Method: 2 in 1 type: Forced and Natural convection, with manual exhaust damper | Heater: 0.6 kW×2 | Exhaust port: 50mm I.D. (Back)×1pc. | Additional functions: Heater operation amount, Power failure recovery mode...
Tokio, Japón
WIRELESS HUMIDITY LOGGER LR8514
- Fabricante: HIOKI E.E
Functionality: [Used as standalone product (Data collected manually) ] Windows PC or Windows tablet (CD-R with software included) Android smartphone or Android tablet terminal (Software can be downloaded free of ...
Nagano, Japón
Yamato CFA611
- Fabricante: Yamato
Method: External closed circulation | Operating temperature range: -10 to +80°C | Temperature control accuracy: ±0.1°C JTM K05 (at 20°C) | Temperature setting, display: Digital setting and display | Temperature i...
Tokio, Japón
Yamato BBL101
- Fabricante: Yamato
System: Pump circulation cooling / external closed circulation | Operating temperature range: -10~+80°C (at room temperature 20°C) | Temperature control accuracy: ±0.1°C | Temp. distribution accuracy: ±0.3°C | Co...
Tokio, Japón
Yamato BBL301
- Fabricante: Yamato
System: Pump circulation cooling / external closed circulation | Operating temperature range: -10~+80°C (at room temperature 20°C) | Temperature control accuracy: ±0.1°C | Temp. distribution accuracy: ±0.3°C | Co...
Tokio, Japón
Yamato BB301
- Fabricante: Yamato
Operating temperature range: -30 to +80°C | Temperature control accuracy: ±0.1°C | Temperature distribution accuracy: ±0.3°C | Temperature indicating unit: 0.1°C | Cooling capacity: Approx. 420W (361Kcal/h), at f...
Tokio, Japón
POWER METER PW3336
Measurement lines: Single-phase 2-wires, single-phase 3-wires, 3-phase 3-wires, (voltage / current measurement range set for each wiring mode) | Measurement items: Voltage, Current, Active power, Apparent power,...
Nagano, Japón
POWER METER PW3337
Measurement lines: Single-phase 2-wires, single-phase 3-wires, 3-phase 3-wires, 3-phase 4-wires (voltage / current measurement range set for each wiring mode) | Measurement items: Voltage, Current, Active power,...
Nagano, Japón
Yamato BB601
- Fabricante: Yamato
Operating temperature range: -30 to +80°C | Temperature control accuracy: ±0.1°C | Temperature distribution accuracy: ±0.3°C | Temperature indicating unit: 0.1°C | Cooling capacity: Approx. 750W (645Kcal/h), at f...
Tokio, Japón