Building Filters
Yamato DNF611
- Fabricante: Yamato
Method: 2 in 1 type: Forced and Natural convection, with manual exhaust damper | Heater: 0.83 kW×2 | Exhaust port: 50mm I.D. (Back)×1pc. | Additional functions: Heater operation amount, Power failure recovery mod...
Tokio, JapónYamato DNF401
- Fabricante: Yamato
Method: 2 in 1 type: Forced and Natural convection, with manual exhaust damper | Heater: 0.6 kW×2 | Exhaust port: 50mm I.D. (Back)×1pc. | Additional functions: Heater operation amount, Power failure recovery mode...
Tokio, JapónYamato CFW611
- Fabricante: Yamato
Method: External closed circulation | Operating temperature range: -10 to +80°C | Temperature control accuracy: ±0.1°C JTM K05 (at 20°C) | Temperature setting, display: Digital setting and display | Temperature i...
Tokio, JapónYamato CFA302
- Fabricante: Yamato
Method: External closed circulation | Operating temperature range: -10 to +60°C | Temperature control accuracy: ±0.1°C JTM K05 (at 20°C) | Temperature setting, display: Digital setting and display | Temperature i...
Tokio, JapónYamato CFA611
- Fabricante: Yamato
Method: External closed circulation | Operating temperature range: -10 to +80°C | Temperature control accuracy: ±0.1°C JTM K05 (at 20°C) | Temperature setting, display: Digital setting and display | Temperature i...
Tokio, JapónPOWER ANALYZER PW6001
Measurement line type: Single-phase 2-wire, single-phase 3-wire, three-phase 3-wire, three-phase 4-wire | Number of input channels: Max. 6 channels; each input unit provides 1 channel for simultaneous voltage and...
Nagano, JapónYamato BBL101
- Fabricante: Yamato
System: Pump circulation cooling / external closed circulation | Operating temperature range: -10~+80°C (at room temperature 20°C) | Temperature control accuracy: ±0.1°C | Temp. distribution accuracy: ±0.3°C | Co...
Tokio, JapónYamato BBL301
- Fabricante: Yamato
System: Pump circulation cooling / external closed circulation | Operating temperature range: -10~+80°C (at room temperature 20°C) | Temperature control accuracy: ±0.1°C | Temp. distribution accuracy: ±0.3°C | Co...
Tokio, JapónYamato BB301
- Fabricante: Yamato
Operating temperature range: -30 to +80°C | Temperature control accuracy: ±0.1°C | Temperature distribution accuracy: ±0.3°C | Temperature indicating unit: 0.1°C | Cooling capacity: Approx. 420W (361Kcal/h), at f...
Tokio, JapónYamato BB601
- Fabricante: Yamato
Operating temperature range: -30 to +80°C | Temperature control accuracy: ±0.1°C | Temperature distribution accuracy: ±0.3°C | Temperature indicating unit: 0.1°C | Cooling capacity: Approx. 750W (645Kcal/h), at f...
Tokio, JapónHORIBA Advanced Techno Co., Ltd. HC-200F
- Fabricante: Horiba
Product name: Fluoride ion meter | Electrode used with product: Fluoride ion electrode | Temperature: 0.1℃ | Linearity: Within ±0.08 mA (output only) | Output type: Contact output with voltage (output of connecte...
Kioto, JapónYamato DF1032
- Fabricante: Yamato
Fan motor: Axial flow fan (capacitor motor: 20W), Two motors used for Model 1032 | Cable port: I.D. ø30mm (rear) | Heat insulator: Glass wool | Other additional structure: Exhaust damper (manual operation) | Safe...
Tokio, JapónYamato DS601
- Fabricante: Yamato
Circulation type: Natural Convection | Operating temp.: Room Temp. +5 to 260°C | Temp. adjustment accuracy: ±1.0°C (at 260°C) | Temp. fluctuation: 3.0°C (at 260°C) | Temp. distribution accuracy: ±5.0°C (at 260°C)...
Tokio, JapónYamato DS611
- Fabricante: Yamato
Circulation type: Natural Convection | Operating temp.: Room Temp. +5 to 260°C | Temp. adjustment accuracy: ±1.0°C (at 260°C) | Temp. fluctuation: 3.0°C (at 260°C) | Temp. distribution accuracy: ±5.0°C (at 260°C)...
Tokio, JapónYamato DS411
- Fabricante: Yamato
Circulation type: Natural Convection | Operating temp.: Room Temp. +5 to 260°C | Temp. adjustment accuracy: ±1.0°C (at 260°C) | Temp. fluctuation: 3.0°C (at 260°C) | Temp. distribution accuracy: ±5.0°C (at 260°C)...
Tokio, Japón