HORIBA Advanced Techno Co., Ltd. HC-200F en Kioto, Japón
Nuevo
Doubleclick to zoom in
Contacte al vendedor
para más fotos y información.
Especificaciones
- Condición
- nuevo
- Product name
- Fluoride ion meter
- Electrode used with product
- Fluoride ion electrode
- Temperature
- 0.1℃
- Linearity
- Within ±0.08 mA (output only)
- Output type
- Contact output with voltage (output of connected power supply voltage)
- Load resistance
- Max.: 900Ω
- Repeatability
- Within ±0.02 mA (output only)
- Output 2
- Temperature: Free setting within a range between -20℃ and 130℃
- Occasional out for error
- Hold or burnout to either 3.8 mA or 21 mA
- Transmission hold
- In the maintenance mode, transmission signal is held at the latest value or preset value. In the calibration mode, transmission signal can be alive or held.
- Contact type
- No-voltage “a” contact of open collector
- Output capacity
- 250 V AC 3 A, 30 V DC 3 A (resistance load)
- Fail
- Error alarm (Closed in the normal state, opened in the failure state or while the power is down.)
- Alarm setting range
- Setting range: within a measuring range Delay time: 0 seconds to 600 seconds
- Control setting range
- Setting range: within a measuring range Control width: 2 mg/L to 40% of the setting range
- Contact capacity
- 250 V AC 0.5 A
- Contact function
- External input for cleaning or transmission holding if cleaner is not attached.
- Cleaning time
- 2 seconds to 600 seconds
- Hold time
- 2 seconds to 600 seconds
- Timer accuracy
- Within 2 minutes per month
- Description of cleaning operation
- Operation of internal timer Operation of internal timer and external input Enable the internal timer only when external input is active. Choose one of the cleaning start signals (when this signal is ON for 2 seconds minimum, the internal cleaning sequence starts).
- Conditions
- ON resistance: 100Ωmax. Open voltage: 24 V DC Short-circuit current: 12 mA DC max.
- Signal type
- 2 wire system, isolated from the input circuit Not isolated from transmission circuit
- Measurement range of temperature
- 0℃ to 100℃
- Temperature calibration
- 1 point calibration comparing reference thermometer
- Kinds of standard solutions
- The first point: Calibrated by the standard solution with the density from 50% to 100% of the measuring range. The second point: Calibrated by the standard solution with the density from 1% to 20% of the measuring range.
- Additional capabilities
- Automatic detection of calibration failure (asymmetry potential,sensitivity, or response time) Calibration history (asymmetry potential, sensitivity, and number of days elapsed after last calibration)
- Electrode diagnostic error
- Temperature sensor short-circuit, temperature sensor disconnection,and out of the temperature measurement range
- Converter error
- CPU error, ADC error, and memory errors
- Operating temperature range
- -20℃ to 55℃ (without freeze)
- Operating humidity range
- Relative humidity: 5% to 90% (without condensation)
- Storage temperature
- -25℃ to 65℃
- Power consumption
- 15 VA (max)
- Others
- With power switch for maintenance use
- Fcc rules
- Part15 Class A
- Installation method
- Mounted on 50 A pole or wall
- Protection code
- IP65
- Case material
- Aluminum alloy (coated with epoxy-denatured melamine resin)
- Material of fittings
- SUS304
- Material of hood
- SUS 304 stainless steel (coated with epoxy-denatured melamine resin)
- Material of window
- Polycarbonate
- Display element
- Reflective monochrome LCD
- External dimensions
- 180 (W) × 155 (H) × 115 (D) mm (excluding mounting brackets)
- Mass
- Main body: Approx. 3.5 kg Cover and mounting brackets: Approx. 1 kg
- Categoría
- Equipo analítico general en Japón
- Subcategoría
- Process water
- Subcategoría 2
- Process and environmental
- ID de Anuncio
- 66608297
Descripción
Field-installation Type Fluoride Ion Concentration Meter
For the management of wastewater from semiconductor/FPD plants and glass factories.
A fluoride ion concentration meter that covers a wide range and offers a diverse lineup of cleaning devices. Combined with the fluoride ion electrode 1009A to detect free fluoride ions in the sample. Ideal for managing wastewater from semiconductor/FPD factories and glass factories.
Supporting a wide range
With a single unit, a wide range from low to high concentrations can be covered.
Comprehensive range of cleaning devices.
A diverse lineup of cleaning devices are offered.
*: When the sensor cable, the transmission cable, or the contact input cable is extended to 30 m or longer, the surge test specified in the EMC directive for CE marking is not applied.
Note
An arrester (spark over voltage: 400 V) is implemented for transmission output, contact input, and communication.