HORIBA Advanced Techno Co., Ltd. HC-200F en Kioto, Japón

Especificaciones

Condición
nuevo
Product name
Fluoride ion meter
Electrode used with product
Fluoride ion electrode
Temperature
0.1℃
Linearity
Within ±0.08 mA (output only)
Output type
Contact output with voltage (output of connected power supply voltage)
Load resistance
Max.: 900Ω
Repeatability
Within ±0.02 mA (output only)
Output 2
Temperature: Free setting within a range between -20℃ and 130℃
Occasional out for error
Hold or burnout to either 3.8 mA or 21 mA
Transmission hold
In the maintenance mode, transmission signal is held at the latest value or preset value. In the calibration mode, transmission signal can be alive or held.
Contact type
No-voltage “a” contact of open collector
Output capacity
250 V AC 3 A, 30 V DC 3 A (resistance load)
Fail
Error alarm (Closed in the normal state, opened in the failure state or while the power is down.)
Alarm setting range
Setting range: within a measuring range Delay time: 0 seconds to 600 seconds
Control setting range
Setting range: within a measuring range Control width: 2 mg/L to 40% of the setting range
Contact capacity
250 V AC 0.5 A
Contact function
External input for cleaning or transmission holding if cleaner is not attached.
Cleaning time
2 seconds to 600 seconds
Hold time
2 seconds to 600 seconds
Timer accuracy
Within 2 minutes per month
Description of cleaning operation
Operation of internal timer Operation of internal timer and external input Enable the internal timer only when external input is active. Choose one of the cleaning start signals (when this signal is ON for 2 seconds minimum, the internal cleaning sequence starts).
Conditions
ON resistance: 100Ωmax. Open voltage: 24 V DC Short-circuit current: 12 mA DC max.
Signal type
2 wire system, isolated from the input circuit Not isolated from transmission circuit
Measurement range of temperature
0℃ to 100℃
Temperature calibration
1 point calibration comparing reference thermometer
Kinds of standard solutions
The first point: Calibrated by the standard solution with the density from 50% to 100% of the measuring range. The second point: Calibrated by the standard solution with the density from 1% to 20% of the measuring range.
Additional capabilities
Automatic detection of calibration failure (asymmetry potential,sensitivity, or response time) Calibration history (asymmetry potential, sensitivity, and number of days elapsed after last calibration)
Electrode diagnostic error
Temperature sensor short-circuit, temperature sensor disconnection,and out of the temperature measurement range
Converter error
CPU error, ADC error, and memory errors
Operating temperature range
-20℃ to 55℃ (without freeze)
Operating humidity range
Relative humidity: 5% to 90% (without condensation)
Storage temperature
-25℃ to 65℃
Power consumption
15 VA (max)
Others
With power switch for maintenance use
Fcc rules
Part15 Class A
Installation method
Mounted on 50 A pole or wall
Protection code
IP65
Case material
Aluminum alloy (coated with epoxy-denatured melamine resin)
Material of fittings
SUS304
Material of hood
SUS 304 stainless steel (coated with epoxy-denatured melamine resin)
Material of window
Polycarbonate
Display element
Reflective monochrome LCD
External dimensions
180 (W) × 155 (H) × 115 (D) mm (excluding mounting brackets)
Mass
Main body: Approx. 3.5 kg Cover and mounting brackets: Approx. 1 kg
Subcategoría
Process water
ID de Anuncio
66608297

Descripción

Field-installation Type Fluoride Ion Concentration Meter
For the management of wastewater from semiconductor/FPD plants and glass factories.
A fluoride ion concentration meter that covers a wide range and offers a diverse lineup of cleaning devices. Combined with the fluoride ion electrode 1009A to detect free fluoride ions in the sample. Ideal for managing wastewater from semiconductor/FPD factories and glass factories.
Supporting a wide range
With a single unit, a wide range from low to high concentrations can be covered.

Comprehensive range of cleaning devices.
A diverse lineup of cleaning devices are offered.
*:  When the sensor cable, the transmission cable, or the contact input cable is extended to 30 m or longer, the surge test specified in the EMC directive for CE marking is not applied.
Note
An arrester (spark over voltage: 400 V) is implemented for transmission output, contact input, and communication.

Contactar al vendedor

Fabricante
Horiba
Modelo
HC-200F
Ubicación
🇯🇵 Kioto, Japón