HORIBA Advanced Techno Co., Ltd. HE-200H
- Fabricante: Horiba
Product name: Conductivity meter | Sensors in combination: 4-electrode method conductivity sensor (FES Series) of cell constant 0.1/cm, or 1.0/cm | Display range: 0.0 to 220.0 | Temperature: 0.01℃ | Nacl: 0.0% to...
Kioto, Japón
HORIBA Advanced Techno Co., Ltd. HE-960RW
- Fabricante: Horiba
Product name: Industrial 2-channel specific resistance meter | Measurement method: Electrode type (2-electrode method) | Sensor input: 2 channels (for concurrent measurement with sensors isolated each other) | Ce...
Kioto, Japón
HORIBA Advanced Techno Co., Ltd. HP-480
- Fabricante: Horiba
Product name: Industrial pH meter | Measuring range: 0 pH to 14 pH: 0.01 pH resolution. Temperature 0℃ to 100℃: 1℃ resolution (selectable display). | Transmission output: 4 mA to 20 mA DC: input/output isolated t...
Kioto, Japón
HORIBA Advanced Techno Co., Ltd. HE-960HI
- Fabricante: Horiba
Product name: Conductivity meter | Measuring method: Four-electrode type | Cell constant: 0.1/cm | Temperature sensor specifications: Resistance thermometer bulb 1000 Ω/0℃ | Temperature: −30℃ to 160℃ | Naoh: 0% t...
Kioto, Japón
HORIBA Advanced Techno Co., Ltd. NO-2000
- Fabricante: Horiba
Product name: Ammonia/Nitrate Nitrogen Meter | Converter model: HC-200N | Sensor model: NO-2000: Nitrate nitrogen sensor | Sensor tip model: 7693: Nitrate ion tip, 7694: Chloride ion tip for compensation, 7211: R...
Kioto, Japón
HORIBA Advanced Techno Co., Ltd. HP-480PL
- Fabricante: Horiba
Product name: Pulse proportional control pH meter for industrial use | Measuring range: 0 pH to 14 pH: 0.01 pH resolution. Temperature 0℃ to 100℃: 1℃ resolution (selectable display). | Transmission output: 4 mA t...
Kioto, Japón
HORIBA Advanced Techno Co., Ltd. HP-480TP
- Fabricante: Horiba
Product name: Industrial pH meter | Measuring range: 0 pH to 14 pH: 0.01 pH resolution. Temperature 0℃ to 100℃: 1℃ resolution (selectable display). | Transmission output: 4 mA to 20 mA DC, input/output isolated t...
Kioto, Japón
HORIBA Advanced Techno Co., Ltd. Finesse Solutions, LLC HE-960CW
- Fabricante: Horiba
Product name: Industrial 2-channel conductivity meter | Measurement method: Electrode type (2-electrode method) | Sensor input: 2 channels (for concurrent measurement with sensors isolated each other) | Cell cons...
Kioto, Japón
HORIBA Advanced Techno Co., Ltd. HE-480C
- Fabricante: Horiba
Nombre del producto: Medidor de conductividad industrial | Método de medición: Tipo de electrodo (método de 2 electrodos) | Constante de celda: 0.01/cm, 0.1/cm, o 1.0/cm | Especificaciones del sensor de temperatu...
Kioto, Japón
HORIBA Advanced Techno Co., Ltd. SS-120-H
- Fabricante: Horiba
Product name: Turbidity detector | Turbidity sensor type: SS-120-H Turbidity detector | Formazin (ntu): 0 to 10.00 (NTU) (Display range: 0 to 11.00 (NTU)) | Psl: 0 to 10.00 (degrees) (Display range: 0 to 11.00 (d...
Kioto, Japón
HORIBA Advanced Techno Co., Ltd. HC-200NH
- Fabricante: Horiba
Combination sensor unit model: DO-2000 | Sensor model: 5700A: Sensor cap | Measurement range: Dissolved oxygen concentration: 0~20mg/L Display resolution 0.01mg/L Saturation degree: 0~200% Display res...
Kioto, Japón
HORIBA Advanced Techno Co., Ltd. 5700A
- Fabricante: Horiba
Measuring method: Optical (fluorescent) | Measuring range: DO: 0 to 20 mg/L Resolution: 0.01 mg/L Saturation: 0 to 200% Resolution: 0.1% Temperature: 0 to 50°C Resolution: 0.1°C | Transmission output: 2...
Kioto, Japón
HORIBA Advanced Techno Co., Ltd. SS-90
- Fabricante: Horiba
Product name: MLSS detector for industrial use | Converter type: HU-200SS industrial-use MLSS converter | Detector type: SS-90 MLSS detector for industrial use | Kaolin: Arbitrary setting within the range from 0 ...
Kioto, Japón
HORIBA Tocadero GmbH Tocadero EVO
- Fabricante: Horiba
Industry: Application example | Pharmaceuticals, medical technology & biotechnology: TOC monitoring in WFI production systems, TOC control in cleaning validation, TOC measurement in cooling water circuits, and TO...
Kioto, Japón
UV500
Sample flow: Recommended : 0 - 5 L/MIN 0 – 0.5 l/min for NH4 or H2S | Sample pressure: 0 – 4 Bar (0 - 1 Bar with sampling peristaltic pump) 0 – 0.5 Bar for NH4 or H2S | Sample temperature: 0 °C to 80 °C 0°C to 30...
Kioto, Japón