Building Filters

HORIBA, Ltd. VA-5000 / VA-5000WM Series
- Fabricante: Horiba
Communication: Ethernet (ModbusTM/TCP) | Output: Maximum 16ch isolated, Maximum voltage DC 30 V, Maximum current 1A Minimum voltage DC 0.1 V, Minimum current 0.1 mA | Sample condition: Ambient temperature, dust f...
Kioto, Japón
HORIBA Advanced Techno Co., Ltd. HO-300
- Fabricante: Horiba
Product name: ORP meter | Combined sensor: ORP electrode | Temperature: 0.1℃ | Linearity: Within ±0.08 mA (output only) | Load resistance: Max.: 600Ω (case of 24 V DC power supply)* 1 | Repeatability: Within ±0.0...
Kioto, Japón
HORIBA Advanced Techno Co., Ltd. Finesse Solutions, LLC HE-960CW
- Fabricante: Horiba
Product name: Industrial 2-channel conductivity meter | Measurement method: Electrode type (2-electrode method) | Sensor input: 2 channels (for concurrent measurement with sensors isolated each other) | Cell cons...
Kioto, Japón
HORIBA, Ltd. 51 series
- Fabricante: Horiba
Measuring principle: Non-Dispersive Infrared Absorption Method (NDIR) | Component: CO, CO 2 , CH 4 , etc. *1 | Span ±0.5% of full scale: Span : ±1.0% of full scale | Linearity: ±1.0% of full scale | Optional ran...
Kioto, Japón
SS-120-W
Product name: Turbidity detector | Turbidity sensor type: SS-120-W Industrial-use turbidity detector | Formazin: 0 to 2000 (Display range: 0 to 2200 ) | Psl: 0 to 100 (degrees) (Display range: 0 to 110 (degrees))...
Kioto, Japón
HORIBA Advanced Techno Co., Ltd. HP-200-K (Four-Wire Analyzer)
- Fabricante: Horiba
Measuring method: Glass electrode method | Measuring range: pH: 0 to 14 pH Resolution: 0.01 pH Temperature: 0 to 100˚C Resolution: 0.1˚C | Repeatability: pH: ±0.03 or less Temperatu...
Kioto, Japón
HORIBA Advanced Techno Co., Ltd. SLIA-5000
- Fabricante: Horiba
Dimensions: 600 (W) mm × 750 (H) mm × 1600 (D) mm | Mass: Approximately 130 kg | Power supply: 100 V AC ±10%, 50/60 Hz (Option) 110 V AC/115 V AC/120 V AC/220 V AC/230 V AC/240 V AC/ 240 V AC±10%, 50/60 Hz | Powe...
Kioto, Japón
HORIBA Advanced Techno Co., Ltd. HE-200R
- Fabricante: Horiba
Product name: Resistivity meter | Combined sensor: 2-electrode method resistivity sensor (ERF-001 Series) of cell constant 0.01/cm | Temperature: Comparison to the accurate thermometer Both deviation and coeffici...
Kioto, Japón
HORIBA Advanced Techno Co., Ltd. SS-150
- Fabricante: Horiba
Product name: Industrial-use turbidity/SS detector | Detector type: SS-150 Industrial-use turbidity/SS detector | Transmission: Measuring principle suitable for SS over 50 mg/L by Kaorin | Kaolin: 0 to 2000 (Disp...
Kioto, Japón
HORIBA Advanced Techno Co., Ltd. HE-480C
- Fabricante: Horiba
Product name: Industrial conductivity meter | Measurement method: Electrode type (2-electrode method) | Cell constant: 0.01/cm, 0.1/cm, or 1.0/cm | Temperature sensor specifications: Platinum resistance 1000 Ω/0℃...
Kioto, Japón
HORIBA Advanced Techno Co., Ltd. HT-110
- Fabricante: Horiba
Product name: Total organic carbon analyzer (TOC analyzer) | Measurement method: Continuous UV oxidation conductivity method | Measurement limit: 0 ppb to 1000 ppb | Measurement range: 0 ppb to 100/500/1000 ppb |...
Kioto, Japón
HORIBA Advanced Techno Co., Ltd. 5800
- Fabricante: Horiba
Product name: Peracetic acid sensor ※3 | Temperature compensation element: Platinum resistance thermometer (Pt1000) 1000 W at 0℃, 3850 ppm/℃ | Measurement range: 100 to 4000ppm (0.010 to 0.400%) | Repeatability: ...
Kioto, Japón
HORIBA Advanced Techno Co., Ltd. SS-120-H
- Fabricante: Horiba
Product name: Turbidity detector | Turbidity sensor type: SS-120-H Turbidity detector | Formazin (ntu): 0 to 10.00 (NTU) (Display range: 0 to 11.00 (NTU)) | Psl: 0 to 10.00 (degrees) (Display range: 0 to 11.00 (d...
Kioto, Japón
HORIBA Advanced Techno Co., Ltd. RA-30
- Fabricante: Horiba
Product name: Rotating electrode polarographic residual chlorine sensor | Sensor type: RA-30 | Temperature: 0.1℃ | Linearity: Within ±0.08 mA (limited to the current linearity) | Output type: Voltage contact outp...
Kioto, Japón
HORIBA Advanced Techno Co., Ltd. 5700A
- Fabricante: Horiba
Measuring method: Optical (fluorescent) | Measuring range: DO: 0 to 20 mg/L Resolution: 0.01 mg/L Saturation: 0 to 200% Resolution: 0.1% Temperature: 0 to 50°C Resolution: 0.1°C | Transmission output: 2...
Kioto, Japón