Building Filters
Yamato DNF911
- Fabricante: Yamato
Method: Forced convection with manual exhaust damper | Heater: 1.65 kW×2 | Exhaust port: 50mm I.D. (Back) x 2pc. | Additional functions: Heater operation amount, Power failure recovery mode, User setting informat...
Tokio, JapónYamato DNF811
- Fabricante: Yamato
- Modelo: DNF811
Method: Forced convection with manual exhaust damper | Heater: 1.35 kW×2 | Exhaust port: 50mm I.D. (Back)×1pc. | Additional functions: Heater operation amount, Power failure recovery mode, User setting informatio...
Tokio, JapónHORIBA Advanced Techno Co., Ltd. CODA-500
- Fabricante: Horiba
Object: COD concentration in water | Dimensions: 600 (W) mm × 510 (D) mm × 1600 (H) mm* 1 | Mass: Approx. 150 kg | Power source: 100 V to 240 V AC ±10%, 50 Hz/60 Hz | Power consumption: 100 V to 120 V AC: Approx....
Kioto, JapónHORIBA Advanced Techno Co., Ltd. HP-200-K (Four-Wire Analyzer)
- Fabricante: Horiba
Measuring method: Glass electrode method | Measuring range: pH: 0 to 14 pH Resolution: 0.01 pH Temperature: 0 to 100˚C Resolution: 0.1˚C | Repeatability: pH: ±0.03 or less Temperatu...
Kioto, JapónYamato BT311
- Fabricante: Yamato
Method: Reciprocating shaking system, Stirring by pump | Operating temp. range: Room temp. +5°C to 80°C(when top cover is installed) | Temperature control accuracy: ±0.02°C to 0.08°C | Temperature distribution ac...
Tokio, JapónYamato DR200
- Fabricante: Yamato
Method: Natural convection | Temp. control range: 300 to 700℃ | Temp. adjustment accuracy: ±5℃(at 700℃) | Temp. distribution accuracy: ±25℃(at 700℃) | Max. temp. reaching time: Approx. 70min. | Interior: Stainles...
Tokio, JapónRealFlow
Repeatability: +/- 0.15% of reading | Uncertainty*: +/- 0.5% of reading | Turndown ratio: 1000:1 | Operating flow range: +/- 0-4000 ml/min | Measurement flow range: 4-4000 ml/min | Measurement rate: 1.1 kHz | Max...
Kioto, JapónHORIBA Advanced Techno Co., Ltd. HD-300
- Fabricante: Horiba
Product name: Dissolved oxygen meter | Combined sensor: 5505, 5510 (A bipolar diaphragm type polarography sensor) | Combined probe: DO-1100 | Saturation degree: 1% | Temperature: 0.1℃ | Linearity: Within ±0.08 mA...
Kioto, Japón- Asakawa, Japón
Case 580G Backhoe Loaders
- Fabricante: Case CE
- Modelo: 580 G
- Caballos de potencia (CV): 52 horsepower
- Peso de funcionamiento: 3,363 kilogram
Color: Amarillo
Asakawa, JapónHORIBA Advanced Techno Co., Ltd. HO-300
- Fabricante: Horiba
Product name: ORP meter | Combined sensor: ORP electrode | Temperature: 0.1℃ | Linearity: Within ±0.08 mA (output only) | Load resistance: Max.: 600Ω (case of 24 V DC power supply)* 1 | Repeatability: Within ±0.0...
Kioto, JapónYamato DKG811V
- Fabricante: Yamato
Method: Forced convection | Operating temperature range: Room temp. +30°C to 260°C | Temperature adjustment accuracy: ±0.5℃ | Temperature distribution accuracy: ±2℃(at 200℃)、±2.5℃(at 260℃) | Time to attain max. t...
Tokio, JapónHORIBA Advanced Techno Co., Ltd. HD-200
- Fabricante: Horiba
Product name: Dissolved oxygen converter | Combined sensor: 5505, 5510 (A bipolar diaphragm type polarography sensor) | Combined probe: DO-1100 | Saturation degree: 1% | Temperature: 0.1℃ | Linearity: Within ±0.0...
Kioto, JapónHORIBA Advanced Techno Co., Ltd. HC-200F
- Fabricante: Horiba
Product name: Fluoride ion meter | Electrode used with product: Fluoride ion electrode | Temperature: 0.1℃ | Linearity: Within ±0.08 mA (output only) | Output type: Contact output with voltage (output of connecte...
Kioto, JapónYamato DHS810
- Fabricante: Yamato
Method: Forced convection and ventilation | Operating temperature range: Room temp.+15~360℃ | Max. temp. reaching time: Approx. 50 min.(at 360℃) | Temperature adjustment accuracy: ±0.3℃(at 360℃) | Temperature dis...
Tokio, Japón