Building Filters
CLAMP ON SENSOR 9694
Rated measurement current: 5 A AC | Max. measurement current: Continuous 50 A (45 to 66 Hz) | Output rate: 10 mV AC/ A | Amplitude accuracy (45 to 66 hz): ±0.3 % rdg. ±0.02 % f.s. | Phase accuracy: ±2° (45 Hz t...
Nagano, JapónYamato DS601
- Fabricante: Yamato
Circulation type: Natural Convection | Operating temp.: Room Temp. +5 to 260°C | Temp. adjustment accuracy: ±1.0°C (at 260°C) | Temp. fluctuation: 3.0°C (at 260°C) | Temp. distribution accuracy: ±5.0°C (at 260°C)...
Tokio, JapónYamato DS611
- Fabricante: Yamato
Circulation type: Natural Convection | Operating temp.: Room Temp. +5 to 260°C | Temp. adjustment accuracy: ±1.0°C (at 260°C) | Temp. fluctuation: 3.0°C (at 260°C) | Temp. distribution accuracy: ±5.0°C (at 260°C)...
Tokio, JapónYamato DS411
- Fabricante: Yamato
Circulation type: Natural Convection | Operating temp.: Room Temp. +5 to 260°C | Temp. adjustment accuracy: ±1.0°C (at 260°C) | Temp. fluctuation: 3.0°C (at 260°C) | Temp. distribution accuracy: ±5.0°C (at 260°C)...
Tokio, JapónCLAMP ON SENSOR 9695-02
Rated measurement current: 50 A AC | Max. measurement current: Continuous 60 A (45 to 66 Hz) | Output rate: 10 mV AC/ A | Amplitude accuracy (45 to 66 hz): ±0.3 % rdg. ±0.02 % f.s. (*1) | Phase accuracy: ±2° (4...
Nagano, JapónCLAMP ON LEAK SENSOR 9657-10
Rated primary current: AC 10 A (for leak current measurement, 50/60 Hz) | Max. allowable input (45-66 hz): Max. 30 A of continuous input | Rated output current: AC 100 mV/A | Amplitude accuracy (45-66 hz): ±1.0...
Nagano, JapónCLAMP ON EARTH TESTER FT6380-50
- Fabricante: HIOKI E.E
Measurement principle: Instrument has two cores for voltage injection and current measurement. From the defined voltage and measured current, the total circuit loop resistance is calculated Note: For multi groun...
Nagano, JapónCLAMP ON SENSOR 9695-03
Rated measurement current: 100 A AC | Max. measurement current: Continuous 130 A (45 to 66 Hz) | Output rate: 1 mV AC/ A | Amplitude accuracy (45 to 66 hz): ±0.3 % rdg. ±0.02 % f.s. (*1) | Phase accuracy: ±1° (...
Nagano, JapónYamato SA400
- Fabricante: Yamato
Shaking method: Double sided vertical shaking | Max. number of separating funnel: 100ml×10, 300ml×8, 1000ml×6 200ml×8, 500ml×8, 2000ml×4 | Shaking speed: horizontal: None | Shaking speed: vertical: 20 to 300 rpm ...
Tokio, JapónYamato DF412
- Fabricante: Yamato
System: Forced convection and ventilation | Operating temp. range: Room temp. + 15 to 260℃ | Temp. control accuracy (jtm k05): ±0.1℃(at 260℃) | Temp. fluctuation (jis): 1.0℃(at 260℃) | Temp. distribution accuracy...
Tokio, JapónYamato DF612
- Fabricante: Yamato
System: Forced convection and ventilation | Operating temp. range: Room temp. + 15 to 260℃ | Temp. control accuracy (jtm k05): ±0.1℃(at 260℃) | Temp. fluctuation (jis): 1.0℃(at 260℃) | Temp. distribution accuracy...
Tokio, JapónYamato DH612
- Fabricante: Yamato
System: Forced convection and ventilation | Operating temp. range: Room temp. + 15 to 360℃ | Temp. control accuracy (jtm k05): ±0.2℃(at 360℃) | Temp. fluctuation (jis): 2.0℃(at 360℃) | Temp. distribution accuracy...
Tokio, JapónYamato DH412
- Fabricante: Yamato
System: Forced convection and ventilation | Operating temp. range: Room temp. + 15 to 360℃ | Temp. control accuracy (jtm k05): ±0.2℃(at 360℃) | Temp. fluctuation (jis): 2.0℃(at 360℃) | Temp. distribution accuracy...
Tokio, JapónYamato BLG200
- Fabricante: Yamato
System: Stirring cooler 80W, with helium refrigerant (not Freon) | Temp. control range: -40°C to 0°C (at ambient temp. of 23°C ± 5°C) | Temp. control accuracy: ±0.3°C (the cooling bath temp. in the stable state) ...
Tokio, JapónYamato BLG100
- Fabricante: Yamato
System: Stirring cooler 80W, with helium refrigerant (not Freon) | Temp. control range: -80°C to 0°C (at ambient temp. of 23°C ± 5°C) | Temp. control accuracy: ±0.3°C (the cooling bath temp. in the stable state) ...
Tokio, Japón