Building Filters
Yamato DVS403
- Fabricante: Yamato
Method: Natural gravity convection | Operating temp. range: Room temp.+5~260℃ | Temp. control accuracy: ±1℃(at 260℃) | Temp. distribution accuracy: ±5℃(at 260℃) | Max. temp. reaching time: Approx. 75 min. | Inter...
Tokio, JapónYamato DVS603
- Fabricante: Yamato
Method: Natural gravity convection | Operating temp. range: Room temp.+5~260℃ | Temp. control accuracy: ±1℃(at 260℃) | Temp. distribution accuracy: ±5℃(at 260℃) | Max. temp. reaching time: Approx. 90 min. | Inter...
Tokio, JapónYamato DTS830
- Fabricante: Yamato
Method: Forced convection | Operating temperature range: Room temp. +30 to 360°C | Temp. control accuracy (jtm k05): ± 0.5°C (at 360°C) | Temp. fluctuation (jis): 1.0°C (at 360°C) | Temperature distribution accur...
Tokio, JapónYamato DKN912
- Fabricante: Yamato
- Modelo: DKN912
Circulation method: Forced air circulation | Operating temp. range: RT +10°C to 210°C | Temp. adjustment accuracy: ±1℃(at 210℃) | Temp. distribution accuracy: ±2.5℃(at 210℃) | Max. temp. reaching time: Approx. 60...
Tokio, JapónYamato DKN402
- Fabricante: Yamato
- Modelo: DKN402
Circulation method: Forced air circulation | Operating temp. range: Room temp. +10°C to 250°C | Temp. adjustment accuracy: ±1℃(at 210℃) | Temp. distribution accuracy: ±2.5℃(at 210℃) | Max. temp. reaching time: Ap...
Tokio, JapónYamato WG1012
- Fabricante: Yamato
Water purifying method: Ion exchange→Distillation→Filtration | Sampled pure water method: Ion-exchanged water / distilled water | Distilled water production: Approximately 5L / h | Amount of distilled water colle...
Tokio, JapónYamato DKN612
- Fabricante: Yamato
Circulation method: Forced air circulation | Operating temp. range: Room temp. +10°C to 250°C | Temp. adjustment accuracy: ±1℃(at 210℃) | Temp. distribution accuracy: ±2.5℃(at 210℃) | Max. temp. reaching time: Ap...
Tokio, JapónYamato DES830
- Fabricante: Yamato
- Modelo: DES830
Method: Forced convection | Operating temperature range: Room temp. +30 to 260°C | Temp. control accuracy (jtm k05): ± 0.5°C (at 260°C) | Temp. fluctuation (jis): 1.0°C (at 260°C) | Temperature distribution accur...
Tokio, JapónYamato DKN302
- Fabricante: Yamato
- Modelo: DKN-302
Circulation method: Forced air circulation | Operating temp. range: Room temp. +10°C to 260°C | Temp. adjustment accuracy: ±1℃(at 210℃) | Temp. distribution accuracy: ±2.5℃(at 210℃) | Max. temp. reaching time: Ap...
Tokio, JapónYamato DKN602
- Fabricante: Yamato
- Modelo: DKN602
Circulation method: Forced air circulation | Operating temp. range: Room temp. +10°C to 250°C | Temp. adjustment accuracy: ±1℃(at 210℃) | Temp. distribution accuracy: ±2.5℃(at 210℃) | Max. temp. reaching time: Ap...
Tokio, JapónINSULATION TESTER IR4056
- Fabricante: HIOKI E.E
Rated output voltage: 50 V DC | Effective maximum indicated value: 100 MΩ | Accuracy 1st effective measuring range mω: ±2 % rdg. ±2 dgt. 0.200 - 10.00 | Lower limit resistance: 0.05 MΩ | Overload protection: 600...
Nagano, JapónINSULATION TESTER ST5520
- Fabricante: HIOKI E.E
Measurement items: Insulation resistance (Applied DC voltage method) | Testing voltage: (Measurement range: AUTO/MANUAL setting is possible) 25 V ≤ V < 100 V (2.000/20.00/200.0 MΩ), 100 V ≤ V < 500 V (2.000/20.0...
Nagano, JapónRESISTANCE METER RM3545
Resistance range: 10 mΩ (12.00000 mΩ display Max., 10 nΩ resolution) to 1000 MΩ range (1200.0 MΩ display Max., 100 kΩ resolution), 12 steps [LP ON] 1000 mΩ (1200.00 mΩ display Max., 10 µΩ resolution) to 1000 Ω ra...
Nagano, JapónYamato DNF601
- Fabricante: Yamato
Method: 2 in 1 type: Forced and Natural convection, with manual exhaust damper | Heater: 0.83 kW×2 | Exhaust port: 50mm I.D. (Back)×1pc. | Additional functions: Heater operation amount, Power failure recovery mod...
Tokio, JapónYamato DNF301
- Fabricante: Yamato
Method: 2 in 1 type: Forced and Natural convection, with manual exhaust damper | Heater: 0.8kW | Exhaust port: 50mm I.D. (Back)×1pc. | Additional functions: Heater operation amount, Power failure recovery mode, U...
Tokio, Japón