Building Filters
HORIBA STEC, Co., Ltd. LSC series
- Fabricante: Horiba
Flow rate generated: H2O 2SLM, TEOS 600 SCCM (Max.) | Operating pressure: Max. 1.33kPa | Source tank volume: 2.7L | Heat regulation method: PID control by the heat regulator | Liquid surface detection method: Flo...
Kioto, JapónHappySelf (G3)
- Fabricante: Teraoka Seiko
Happyself(g3): Option selection | Control unit: OS; Linux; - | Main storage: SSD: 32GB or more HDD: 500GB or more; - | Interface: USB2.0 port; Side (left) x 6 Side (right) x 1; - | Serial port: RS-232C x 4 | Scan...
Tokio, JapónHORIBA Advanced Techno Co., Ltd. HE-960HC
- Fabricante: Horiba
Measurement range: 0 - 1000mS/cm | Wetted materials: GC, Karletz, PFA | Sensor input: 1 ch | Repeatability: +/- 0.5% of the full scale (in equivalent input) | Linearity: +/- 0.5% of the full scale (in equivalent ...
Kioto, JapónPFS-ONE
- Fabricante: HORIBA Europe GmbH
Hardware: standard desktop PC | Min. 8 gb memory: min. 16 GB memory | Software: application software for PFS-ONE Control Unit | Windows 10: Windows 10 or Windows 11 | Legislation compliance: ECE-R83, ECE-R49, EPA...
Kioto, JapónHORIBA, Ltd. EV-140C
- Fabricante: Horiba
Wavelength range: 200 - 800 nm | Optical resolution: <2.0 nm @ =200 - 500 nm <2.5 nm @ =500 - 700 nm (FWHM theoretical resolution) | Design: Aberration corrected Flat field concave grating | Focal length: 1...
Kioto, JapónHORIBA Advanced Techno Co., Ltd. CS-620F
- Fabricante: Horiba
Product name: CHEMICAL SOLUTION MONITOR | Measurement principle: Absorption spectroscopic method | Calculation principle: Temperature compensation type multivariate analysis | Sample: H 3 PO 4 /H 2 O | Conditions...
Kioto, JapónIN-CIRCUIT TESTER FA1220
- Fabricante: HIOKI E.E
Number of test points: Max. 1024 pins (Can be added in blocks of 128 pins.) Standard : 0 pins (Scanner boards are sold as options.) | Number of test steps: Round-robin short/open data : 1024 pins Component data :...
Nagano, JapónHORIBA Advanced Techno Co., Ltd. OPSA-150
- Fabricante: Horiba
Product name: Organic Pollutant Monitor (UV meter) | Measurement item: UV absorbance, VIS absorbance, COD conversion concentration, TURB (turbidity) conversion concentration | Measurement principle: Dual optical ...
Kioto, JapónHORIBA Advanced Techno Co., Ltd. CS-600F
- Fabricante: Horiba
Measurement principle: Absorption spectroscopic method | Calculation principle: Temperature compensation type multivariate analysis | Measurement target: NH 3 /H 2 O 2 /H 2 O (reperesentative specification) * Ple...
Kioto, JapónHORIBA Advanced Techno Co., Ltd. HD-960L
- Fabricante: Horiba
Model name: HD-960L | 0.0 to 200.0 μg/l: +/-1% FS | 200 to 2000μg/l: +/-1% FS | 2.00 to 20.00mg/l: +/-1% FS | Sample flow rate: 15 to 200ml /min. | Sample temperature: 10 to 45 °C | Sample hf concentration: 0 to ...
Kioto, JapónHORIBA Advanced Techno Co., Ltd. CS-900
- Fabricante: Horiba
Model name: Non-contact type chemical concentration monitor | Measurement method: Absorption spectroscopy | Concentration calculation: Temperature compensated multivariate analysis | Conditions of measurement: 1)...
Kioto, JapónHORIBA Advanced Techno Co., Ltd. SLIA-300
- Fabricante: Horiba
Principle: Molybdenum blue method | Measuring range: 0 to 2/0 to 20µg/L or 0 to 5/0 to 50 µg/L (specified when ordering) | Repeatability: ±2% of full scale | Measuring time: 5 minutes | Measuring cycle: 5 to 995 ...
Kioto, JapónHORIBA Advanced Techno Co., Ltd. CS-100F1 Series
- Fabricante: Horiba
Measurement principle: Absorption spectrometry | Concentration computation principle: Temperature-compensated multivariate analysis | Sample solution temperature: 20 to 80: (when using Inline cell) 20 to 30: (whe...
Kioto, JapónIN-CIRCUIT TESTER FA1220-11
- Fabricante: HIOKI E.E
Number of test points: Standard: 0 pins (scanner boards optional) Max. 2048 pins (expandable in blocks of 128 pins)* * The maximum number of active pins for each test type depends on the total number of scanner b...
Nagano, JapónMEXA-730λ
- Fabricante: HORIBA, Ltd.
Model name: MEXA-730λ | Display range: A/F : 3.99 to 500.0 λ : 0.275 to 30.00 O 2 : 0.00 to 99.99 vol% | Accuracy of a/f: (Guarantee range is from 9.5 to 200 A/F) (Model gas at room temperature, atmospheric press...
Kioto, Japón