HIGH VOLTAGE SCANNER 3930
Operation modes: Multi-mode: Scanning of user-selected points for high 4 ch / low 4 ch Single mode: Common scan of high 8 ch - common | Rated voltage used: 5 kV AC / 5 kV DC | Operation indications: Lamps light u...
Nagano, JapónHORIBA Advanced Techno Co., Ltd. HC-200F
- Fabricante: Horiba
Product name: Fluoride ion meter | Electrode used with product: Fluoride ion electrode | Temperature: 0.1℃ | Linearity: Within ±0.08 mA (output only) | Output type: Contact output with voltage (output of connecte...
Kioto, JapónYamato DH832
- Fabricante: Yamato
System: Forced air circulation and ventilation | Operating temp. range: Room temp. +15°C~300°C | Temperature fluctuation: 3.0°C (at 300°C) | Temperature slope: 18°C (at 300°C) | Temperature controller: PID contro...
Tokio, JapónYamato DF832
- Fabricante: Yamato
Fan motor: Axial flow fan (capacitor motor: 20W) | Cable port: I.D. ø30mm (rear) | Heat insulator: Glass wool | Other additional structure: Exhaust damper (manual operation) | Safety device: Self-diagnostic funct...
Tokio, JapónMEXA-1170HCLD
- Fabricante: HORIBA, Ltd.
Components: NO, NO x | Principle: Chemiluminescence detection (heated) | Sample gas flow rate: MEXA-1170HCLDA (Atmospheric type) Approx. 3 l/min | Sample gas pressure: Between -5 kPa and 30 kPa | Ambient humidity...
Kioto, JapónHORIBA, Ltd. EMGA-Expert (EMGA-21E)
- Fabricante: Horiba
Measurement target element: Hydrogen | Measurement gas type: H 2 | Detector: TCD | Measurement range* *up to 100% wt is possible by decreasing the sample weight: 0.04 ppm-0.02% | Precision / repeatability: σn-1-≦...
Kioto, JapónYamato DKG811V
- Fabricante: Yamato
Method: Forced convection | Operating temperature range: Room temp. +30°C to 260°C | Temperature adjustment accuracy: ±0.5℃ | Temperature distribution accuracy: ±2℃(at 200℃)、±2.5℃(at 260℃) | Time to attain max. t...
Tokio, JapónYamato IN604W
- Fabricante: Yamato
System: Forced air convection | Operating temperature range: -10~50℃ | Temperature adjustment accuracy: ±0.3℃(when refrigerator is in continuous operation), ±1.0℃(when refrigerator is in cycle operation) | Temper...
Tokio, JapónYamato GB210-A
- Fabricante: Yamato
Temp. adjusting range: 40 to 220°C (inlet temperature), 0 to 60°C (Outlet temperature) | Temperature adjusting accuracy: Inlet temperature±1°C | Spraying system: Two-way nozzle, Nozzle No. 1A as standard | Drying...
Tokio, JapónMEXA-1170HFID
- Fabricante: HORIBA, Ltd.
Principle: Flame ionization detection (heated) | Ranges: 0-10 ppmC to 0-200,000 ppmC (Max. 14 ranges) | Response time(t90): Within 1.5 sec (by switching zero line and span line for calibration) | Repeatability: W...
Kioto, JapónHORIBA France SAS Custom Solutions - OEM Raman
- Fabricante: Horiba
Kioto, JapónYamato DR200
- Fabricante: Yamato
Method: Natural convection | Temp. control range: 300 to 700℃ | Temp. adjustment accuracy: ±5℃(at 700℃) | Temp. distribution accuracy: ±25℃(at 700℃) | Max. temp. reaching time: Approx. 70min. | Interior: Stainles...
Tokio, JapónYamato ADL311S-A
- Fabricante: Yamato
Temp. adjusting unit setting range: 40 to 220°C (inlet temperature), 0 to 60°C (Outlet temperature) | Temperature adjusting accuracy: Inlet temperature±1°C | Drying air amount adjusting range: 0 to 0.7m3/min | Sp...
Tokio, JapónHORIBA, Ltd. IT-480 series
- Fabricante: Horiba
Spectral response: 8μm to 14μm | Measured temperature range: -50℃ to 500℃ | Output: USB (resolution = 0.1℃) Current (4 mA to 20 mA, resolution =0.24μA, non-insulated) | Currnent output range: -50℃ to 500℃ (factor...
Kioto, JapónHORIBA Advanced Techno Co., Ltd. HR-480
- Fabricante: Horiba
Product name: Industrial Residual Chlorine Meter | Measurement method: Galvanic cell method | Repeatability: Within ±0.05 mg/L (with equivalent input) | Linearity: Within ±0.05 mg/L (with equivalent input) | Tran...