Building Filters
FLYING PROBE TESTER FA1240-6x
- Fabricante: HIOKI E.E
Number of arms: 4 (L, ML, MR, R) | Number of test steps: 40,000 (max.) | Measurement ranges: Resistance: 400 μΩ to 40 MΩ Capacitance: 1 pF to 400 mF Inductance: 1 μH to 100 H Diode VZ measurement: 0 to 25 V Zener...
Nagano, Japón100mg/h Integrated Ceramic Plate Ozone Generator UnitsI means integrated, L means long life ceramic
Ceramic plates: means integrated, means long life ceramic | Cooling method: Air cooling for transformer and ceramic plate
Shanghái, ChinaCLAMP ON PROBE 3276
- Fabricante: HIOKI E.E
Frequency bandwidth: DC to 100 MHz (-3 dB) | Rise time: 3.5 ns or shorter | Noise level: 2.5 mA rms max. (bandwidth limited to 20 MHz) | Continuous allowable input: 30 A rms (requires derating at frequency) | Max...
Nagano, JapónANALOG MΩ HiTESTER 3490
- Fabricante: HIOKI E.E
Rated output voltage: 250 V DC | Effective maximum indicated value: 100 MΩ | Accuracy 1st effective measuring range: ±2 % of scale length 0.05 to 50 MΩ | Lower limit resistance: 0.25 MΩ | Overload protection: 660...
Nagano, JapónCURRENT PROBE CT6701
- Fabricante: HIOKI E.E
Frequency bandwidth: DC to 120 MHz (-3 dB) | Rise time: 2.9 ns or shorter | Noise level: 60 μA rms typical, 75 μA rms max (for 30 MHz band measuring instrument) | Continuous allowable input: 5 A rms (DC, and sine...
Nagano, JapónANALOG MΩ HiTESTER IR4018
- Fabricante: HIOKI E.E
Rated output voltage: 1000 V DC | Effective maximum indicated value: 2000 MΩ | Accuracy 1st effective measuring range: ±2 % of scale length, 2 M to 1000 MΩ | Lower limit resistance: 1 MΩ (measurement resistance v...
Nagano, JapónANALOG MΩ HiTESTER IR4017
- Fabricante: HIOKI E.E
Rated output voltage: 500 V DC | Effective maximum indicated value: 1000 MΩ | Accuracy 1st effective measuring range: ±2 % of scale length, 1 M to 500 MΩ | Lower limit resistance: 0.5 MΩ (measurement resistance v...
Nagano, JapónANALOG MΩ HiTESTER IR4016
- Fabricante: HIOKI E.E
Rated output voltage: 500 V DC | Effective maximum indicated value: 100 MΩ | Accuracy 1st effective measuring range: ±2 % of scale length, 0.1 M to 50 MΩ | Lower limit resistance: 0.5 MΩ (measurement resistance v...
Nagano, Japón6ES7144-6KD00-0AB0 ET200ECO PN, 8AI; 4 U/I; 4 RTD/TC 8XM12
Artikelnummer: 6ES7144-6KD00-0AB0 | Vendor identification (vendorid): 002AH | Device identifier (deviceid): 0306H | 24 v dc: Yes | Permissible range, lower limit (dc): 20.4 V | Permissible range, upper limit (dc)...
Shenzhen, ChinaNon-Linear Junction Detector FJT-C-S6
- Fabricante: Beijing Topsky Intelligent Equipment Group
Relative humidity: when the temperature is 25 ℃, not more than 80%. | A) transmission frequency: 2400.5MHz — 2485.5MHz; | B) signal form: Pulse duty cycle of 5% Pulse width: 500us | C) transmitter power: 3.7W(pea...
Pekín, ChinaLT-BAT Electric Forcible Entry Kit
- Fabricante: BAT
Pekín, ChinaThermostatic Incubator
- Fabricante: Thermo Fisher Scientific
Pekín, ChinaMDXN-31D2 Mask aligner
5.exposure type: capacidad del tanque de gas LP | 6.exposure area: φ100mm; | 7.uneven exposure: ≤±3%; | 8.exposure intensity: ≥5mw/cm2; | 9.exposure resolution: 2μm; | 10.exposure mode: Exposición simultánea en d...
Cantón, China- Cantón, China
FCS IMM for PET Blood Collection Tubes (SA-h PET Series)
- Fabricante: FCS
Tainan, Taiwán