Building Filters

UV500
Sample flow: Recommended : 0 - 5 L/MIN 0 – 0.5 l/min for NH4 or H2S | Sample pressure: 0 – 4 Bar (0 - 1 Bar with sampling peristaltic pump) 0 – 0.5 Bar for NH4 or H2S | Sample temperature: 0 °C to 80 °C 0°C to 30...
Kioto, Japón
SUPER MΩ HiTESTER SM7810
Número de canales: 8 canales (medición paralela y simultánea) | Tensión aplicada: Suministro de tensión desde una fuente de alimentación externa (terminal de entrada de tensión en el panel trasero) | Rango de med...
Nagano, Japón
AC/DC CURRENT SENSOR CT6904A, CT6904A-1
Rated current: 500 A AC/DC | Max. allowable input: Within the derating range, However, up to ±1000 A peak is allowable if within 20 ms. (design value) | Frequency bandwidth: Amplitude: DC to 4 MHz (CT6904A), DC t...
Nagano, Japón
SENSOR DE CORRIENTE AC/DC CT6875A
Corriente nominal: 500 A AC/DC | Entrada máxima permitida: Dentro del rango de derivación, permitido hasta ±1500 A pico (valor de diseño) a 40°C o menos durante 20 ms o menos | Ancha de banda de frecuencia: Ampli...
Nagano, Japón
AC LEAKAGE CLAMP METER CM4001
Ac current range: 60.00 mA/ 600.0 mA/ 6.000 A/ 60.00 A/ 600.0 A, 5 ranges (40 Hz to 1 kHz, True RMS) Basic accuracy (45-66 Hz): ±1.5% rdg ±5 dgt (60.00 mA to 6.000 A), ±2.5% rdg ±5 dgt (60.00 A to 600.0 A) Guaran...
Nagano, Japón
WIRELESS HUMIDITY LOGGER LR8514
- Fabricante: HIOKI E.E
Functionality: [Used as standalone product (Data collected manually) ] Windows PC or Windows tablet (CD-R with software included) Android smartphone or Android tablet terminal (Software can be downloaded free of ...
Nagano, Japón
IMPEDANCE ANALYZER IM7583
Measurement modes: LCR mode, Analyzer mode (Sweeps with measurement frequency and measurement level), Continuous measurement mode | Measurement parameters: Z, Y, θ, Rs (ESR), Rp, X, G, B, Cs, Cp, Ls, Lp, D (tanδ...
Nagano, Japón
IMPEDANCE ANALYZER IM7587
Measurement modes: LCR mode, Analyzer mode (sweeps with measurement frequency and measurement level), Continuous measurement mode | Measurement parameters: Z, Y, θ, Rs (ESR), Rp, X, G, B, Cs, Cp, Ls, Lp, D (tanδ...
Nagano, Japón
IMPEDANCE ANALYZER IM7580A
Measurement modes: LCR mode, Analyzer mode (Sweeps with measurement frequency and measurement level), Continuous measurement mode | Measurement parameters: Z, Y, θ, Rs (ESR), Rp, X, G, B, Cs, Cp, Ls, Lp, D (tanδ...
Nagano, Japón
IMPEDANCE ANALYZER IM7581
Measurement modes: LCR mode, Analyzer mode (Sweeps with measurement frequency and measurement level), Continuous measurement mode | Measurement parameters: Z, Y, θ, Rs (ESR), Rp, X, G, B, Cs, Cp, Ls, Lp, D (tanδ...
Nagano, Japón
IMPEDANCE ANALYZER IM7585
Measurement modes: LCR mode, Analyzer mode (sweeps with measurement frequency and measurement level), Continuous measurement mode | Measurement parameters: Z, Y, θ, Rs (ESR), Rp, X, G, B, Cs, Cp, Ls, Lp, D (tanδ...
Nagano, Japón
SENSOR DE CORRIENTE AC/DC CT6872
Corriente nominal: 50 A AC/DC | Entrada máxima permitida: Dentro del rango de derating, permitido hasta ±150 A Pico (valor de diseño) a 40°C o menos durante 20 ms o menos | Ancha de banda de frecuencia: Amplitud:...
Nagano, Japón
AC/DC CURRENT SENSOR CT6904A-2, CT6904A-3
Rated current: 800 A AC/DC | Max. allowable input: Within the derating range, However, up to ±1200 A peak is allowable if within 20 ms. (design value) | Frequency bandwidth: Amplitude: DC to 4 MHz (CT6904A-2), DC...
Nagano, Japón
SENSOR DE CORRIENTE AC/DC CT6873
Corriente nominal: 200 A AC/DC | Entrada máxima permitida: Dentro del rango de derivación, permitida hasta ±420 A pico (valor de diseño) a 40°C o menos durante 20 ms o menos | Ancha de banda de frecuencia: Amplit...
Nagano, Japón
SENSOR DE CORRIENTE AC/DC CT6862-05
Corriente nominal: 50 A AC/DC | Entrada máxima permitida: Dentro del rango de derating, permitido hasta ±150 A Pico (valor de diseño) a 40°C o menos durante 20 ms o menos | Ancha de banda de frecuencia: Amplitud:...
Nagano, Japón