Building Filters
- Pekín, China
FU160 3000/5a busbar split core type current transformer
Standards: IEC/EN60044-1 & IEC61010-1 & IEC61869-2&ANSI C57.13 | Accuracy: 0.2%, 0.5%, 1% | Ratio: 601, 1201 or 20001, customized | Nominal input current (primary current): 300A/400A/500A/600A/750A/800A/1000A/120...
Pekín, ChinaLZCK-55 clamp outdoor waterproof split core current transformer
Standards: IEC60044-1; IEC 61869-2; NTC 2205; GB1208-2006; GB/T20840.2; ANSI/IEEE C57.13 | Accuracy class: 0.5S, 0.5% , 1% , 3% | Range of primary rated current: 100-1000A | Range of rated load: ≤10VA | Rated fre...
Pekín, ChinaGFLZZ0746-10GY 2000A/5A wound type medium voltage current transformer
Standards: IEC60044; IEC 61869; ANSI/IEEE C57.13 | Rated primary current: 5-3150A | Rated load: ≤60VA | Rated frequency: 50Hz or 60Hz | Rated secondary current: 5A or 1A | Rated short-time thermal current: 120kA,...
Pekín, Chinalzck-120 outdoor 120mm window ip67 split core ct transformer
Standards: iec60044-1; iec 61869-2; ntc 2205; gb1208-2006; gb/t20840.1&2; ansi/ieee c57.13 | Accuracy class: 0.5S, 0.5% , 1% , 3% (IEC61869 standard) | Range of primary rated current: 300-3000A | Range of rated l...
Pekín, ChinaLMCK185-10 IP65 waterproof split core outdoor current transformer
Standards: IEC60044-1; IEC 61869-2; NTC 2205; GB1208-2006; GB/T20840.1 & 2; ANSI/IEEE C57.13 | Accuracy class: 0.5S, 0.5% , 1% , 3% (IEC61869 standard) | Range of primary rated current: 300-5000A | Range of rated...
Pekín, ChinaFU120 low voltage bus bar type split core current transformer
Standards: IEC/EN60044-1 & IEC61010-1 & IEC61869-2&ANSI C57.13 | Accuracy: 0.2%, 0.5%, 1% | Ratio: 601, 1201, 3000/5A or 10001, customized | Nominal input current (primary current): 300A/400A/500A/600A/750A/800A/...
Pekín, ChinaLZCT722-10 electrical cast resin zct zero sequence current transformer
Standards: IEC60044-1; IEC 61869-2; NTC 2205; ANSI/IEEE C57.13; GB1206-2006; | Class: 0.2S, 0.2, 0.5S, 0.5, 1, 3, 10P10, 10P, 10P20 | Rated primary current: 50-1500A | Rated load: ≤25VA | Rated frequency: 50Hz or...
Pekín, ChinaLZCG530-10 11KV cast epoxy resin straight-through current transformer
Standards: IEC60044-1; IEC 61869-2; NTC 2205; ANSI/IEEE C57.13; GB1206-2006; | Accuracy class: 0.2S, 0.2, 0.5S, 0.5 (IEC61869 standard) | Rated primary current: 30-1000A | Rated load: ≤20VA | Rated frequency: 50H...
Pekín, ChinaLZCG930-10 cheap low voltage cast resin ring core current transformer
Standards: IEC60044-1; IEC 61869-2; NTC 2205; ANSI/IEEE C57.13; GB1206-2006; | Accuracy class: 0.2S, 0.2, 0.5S, 0.5 (IEC61869-2 standard) | Rated primary current: 30-1000A | Rated load: ≤30VA | Rated frequency: 5...
Pekín, ChinaFU-80 low cost indoor single phase split core current transformer
Standards: IEC/EN60044-1 & IEC61010-1 & IEC61869-2&ANSI C57.13 | Accuracy: 0.2% , 0.5S, 0.5 % , 1% | Ratio: 1001, 10005 or 10001, customized | Nominal input current (primary current): 100a/150a/200a/250a/300a/400...
Pekín, ChinaLZCK2500-10 high accuracy 33KV split core zero phase current transformer
Standards: IEC60044-1; IEC 61869-2; NTC 2205; ANSI/IEEE C57.13; GB1206-2006; | Class: 0.5, 1, 3, 10P10, 10P5, 10P20 | Rated primary current: 50-2000A | Rated load: ≤25VA | Rated frequency: 50Hz or 60Hz | Rated se...
Pekín, China- Pekín, China
LZCK350-10 100/5A epoxy resin cast split core current transformer
Standards: IEC60044-1; IEC 61869-2; NTC 2205; ANSI/IEEE C57.13; GB1206-2006; | Rated primary current: 30-1000A | Rated load: ≤25VA | Rated frequency: 50Hz or 60Hz | Rated secondary current: 5A or 1A | Rated short...
Pekín, ChinaLZCK322-10 11KV 33KV high voltage split core CT current transformer
Standards: IEC60044-1; IEC 61869-2; NTC 2205; ANSI C57.13; GB1208-2006; | Class: 0.5, 1, 3 | Rated primary current: 30-1000A | Rated load: ≤15VA | Rated frequency: 50Hz or 60Hz | Rated secondary current: 5A or 1A...
Pekín, China