Yamato BH401
- Fabricante: Yamato
Circulation system: Water jet pump circulation / External closed circulation | Operating temperature range: RT+15~100°C | Temperature adjustment accuracy: ±0.01°C (water: RT+15°C~80°C) | Temperature indication un...
Tokio, JapónYamato BT101
- Fabricante: Yamato
Method: Reciprocating shaking system, Stirring by pump | Operating temp. range: Room temp. +5°C to 80°C(when top cover is installed) | Temperature control accuracy: ±0.02°C to 0.08°C | Temperature distribution ac...
Tokio, JapónYamato BH501
- Fabricante: Yamato
Pump max. flow(50/60hz): 14/15L/min. (Circulation pressure loss when below 10kPa) | Pump max. lift(50/60hz): 2.8/3.4m (water flow about 0.5L/min) | Circulation system: Water jet pump circulation /External closed ...
Tokio, JapónYamato FP102
- Fabricante: Yamato
Operating temp. range: 100~1,150℃ | Temp. control accuracy: ±1.0℃(at 1150℃) | Temp. fluctuation: 2.0℃(at 1150℃) | Temp. distribution: ±4.0℃(at 1150℃) | Temp. gradient: 14℃(at 1150℃) | Max. temp. reaching time: Ap...
Tokio, JapónHORIBA Scientific FLIMera
- Fabricante: Horiba
Modality: Widefield Time-Domain TCSPC | Sensor: SPAD CMOS with In-Pixel TDC | Sensor wavelength range: 400 to 900 nm | Max total count rate: Up to 295 Mcps theoretical | Max pixel count rate: 12 kcps | Image arra...
Kioto, JapónHORIBA, Ltd. EV-140C
- Fabricante: Horiba
Wavelength range: 200 - 800 nm | Optical resolution: <2.0 nm @ =200 - 500 nm <2.5 nm @ =500 - 700 nm (FWHM theoretical resolution) | Design: Aberration corrected Flat field concave grating | Focal length: 1...
Kioto, JapónHORIBA Scientific Hyperspectral PoliSpectra® H116
- Fabricante: Horiba
Spectral coverage: 185–1050 nm Tunable at factory between these ranges: 185-920 nm and 280-1050 nm | Spectral resolution: 1.25 nm typical (22 μm slit width) and up, depending on the slit size | Spatial resolution...
Kioto, JapónHORIBA Advanced Techno Co., Ltd. CS-900
- Fabricante: Horiba
Model name: Non-contact type chemical concentration monitor | Measurement method: Absorption spectroscopy | Concentration calculation: Temperature compensated multivariate analysis | Conditions of measurement: 1)...
Kioto, JapónYamato DKG811V
- Fabricante: Yamato
Method: Forced convection | Operating temperature range: Room temp. +30°C to 260°C | Temperature adjustment accuracy: ±0.5℃ | Temperature distribution accuracy: ±2℃(at 200℃)、±2.5℃(at 260℃) | Time to attain max. t...
Tokio, JapónHORIBA Scientific InVizU Cube
- Fabricante: Horiba
Spectral coverage: 200 - 1,700 nm | Spectrometer input: Input port: SMA for UV-VIS and custom-end ferrule for NIR (see drawing for details) | Spectral resolution: < 6 nm | Average spectral dispersion: 17 nm/mm...
Kioto, JapónHORIBA Advanced Techno Co., Ltd. HE-200H
- Fabricante: Horiba
Product name: Conductivity meter | Sensors in combination: 4-electrode method conductivity sensor (FES Series) of cell constant 0.1/cm, or 1.0/cm | Display range: 0.0 to 220.0 | Temperature: 0.01℃ | Nacl: 0.0% to...
Kioto, JapónHORIBA Advanced Techno Co., Ltd. HE-200C
- Fabricante: Horiba
Product name: Conductivity meter | Sensors in combination: 2-electrode method conductivity sensor ESH, ESD, ESL, and FS Series sensor of cell constant 0.01/cm,0.1/cm, or 1.0/cm | Temperature: 0.01℃ | Linearity: W...
Kioto, JapónCLAMP ON EARTH TESTER FT6380-50
- Fabricante: HIOKI E.E
Measurement principle: Instrument has two cores for voltage injection and current measurement. From the defined voltage and measured current, the total circuit loop resistance is calculated Note: For multi groun...
Nagano, JapónHORIBA Scientific MiniVS70
- Fabricante: Horiba
Spectral coverage: 200 - 1050 nm with double-blazed 365 l/mm grating, 190 – 850 nm with 477 l/mm grating, ≤ 400 – ≥ 800 nm with 582 l/mm grating | Spectral resolution: 2 nm for 365 l/mm grating, 1 nm for 477 l/mm...
Kioto, JapónHORIBA France SAS EV 2.0 Series
- Fabricante: Horiba
System outline: The small sized spectrometer is based on a concave holographic grating (aberration corrected) with 20mm focal length (LR) or 75 mm focal length (STD, HR) or 99 mm focal length (HTR) and 50/25 µm s...
Kioto, Japón