AC/DC CURRENT PROBE CT6841A
Rated current: 20 A AC/DC | Frequency bandwidth: DC to 2 MHz | Diameter of measurable conductors: Max. φ 20 mm (0.79 in.) | Max. allowable input: ±60 A peak (Within 20 ms in an environment of 40°C/104°F or less)...
Nagano, JapónAC/DC CURRENT PROBE CT6844A
Rated current: 500 A AC/DC | Frequency bandwidth: DC to 500 kHz | Diameter of measurable conductors: Max. φ 20 mm (0.79 in.) | Max. allowable input: ±800 A peak (Within 20 ms in an environment of 40°C/104°F or le...
Nagano, JapónAC/DC CURRENT SENSOR CT6877A
Rated current: 2000 A AC/DC | Max. allowable input: Within the derating range, (within the specified range up to ±3200 Apeak ) | Frequency characteristics: Amplitude: DC to 1 MHz, Phase: DC to 700 kHz | Basic acc...
Nagano, JapónCARD HiTESTER 3244-60
Dc voltage range: 419.9 mV to 500 V, 5 ranges, Basic accuracy: ±0.7 % rdg. ±4 dgt. | Ac voltage range: 4.199 V to 500 V, 4 ranges, Basic accuracy 50 - 500 Hz : ±2.3 % rdg. ±8 dgt. (Average rectified) | Resistanc...
Nagano, JapónPENCIL HiTESTER 3246-60
Dc voltage range: 419.9 mV to 600 V, 5 ranges, Basic accuracy: ±1.3 % rdg. ±4 dgt. | Ac voltage range: 4.199 V to 600 V, 4 ranges, Basic accuracy 50 - 500 Hz : ±2.3 % rdg. ±8 dgt. (Average rectified) | Resistance...
Nagano, JapónDIGITAL MULTIMETER DT4253
Dc voltage range: 600.0 mV to 1000 V 5 ranges, Basic accuracy: ±0.3 % rdg. ±5 dgt. | Ac voltage range: 6.000 V to 1000 V, 4 ranges, Frequency characteristics: 40 Hz to 1 kHz Basic accuracy 40 - 500 Hz : ±0.9 % rd...
Nagano, JapónDIGITAL MULTIMETER DT4261
Dc voltage range: 600.0 mV to 1000 V, 5 ranges, Basic accuracy: ±0.15% rdg. ±2 dgt. | Ac voltage range: 6.000 V to 1000 V, 4 ranges, Frequency characteristics: 40 Hz to 1 kHz Basic accuracy 40 Hz - 500 Hz: ±0.9% ...
Nagano, JapónDIGITAL MULTIMETER DT4223
Dc voltage range: 600.0 mV to 600.0 V, 4 ranges, Basic accuracy: ±0.5 % rdg. ±5 dgt. | Ac voltage range: 6.000 V to 600.0 V, 3 ranges, Frequency characteristics: 40 Hz - 1 kHz Basic accuracy 40 - 500 Hz : ±1.0 % ...
Nagano, JapónDIGITAL MULTIMETER DT4224
Dc voltage range: 600.0 mV to 600.0 V, 4 ranges, Basic accuracy: ±0.5 % rdg. ±5 dgt. | Ac voltage range: 6.000 V to 600.0 V, 3 ranges, Frequency characteristics: 40 Hz - 1 kHz Basic accuracy 40 - 500 Hz : ±1.0 % ...
Nagano, JapónDMM STATION MR8990+MR8741/MR8740
Measurement functions: Install into Memory HiCorder MR8740/8741 for use; 2 channels of DC voltage measurement | Measurement ranges (20 div. f.s.): 100 mV range (5 mV/div.): -120.0000 mV to 120.0000mV, 0.1 μV reso...
Nagano, JapónDIGITAL MULTIMETER DT4281
Dc voltage range: 60.000 mV to 1000.0 V, 6 ranges, Basic accuracy: ±0.025 % rdg. ±2 dgt. | Ac voltage(*1) range: 60.000 mV to 1000.0 V, 6 ranges, Frequency characteristics: 20 Hz - 100 kHz Basic accuracy 45 - 65 ...
Nagano, JapónDIGITAL MULTIMETER DT4282
Dc voltage range: 60.000 mV to 1000.0 V, 6 ranges, Basic accuracy: ±0.025 % rdg. ±2 dgt. | Ac voltage(*1) range: 60.000 mV to 1000.0 V, 6 ranges, Frequency characteristics: 20 Hz - 100 kHz Basic accuracy 45 - 65 ...
Nagano, JapónAC/DC CURRENT SENSOR CT6904A, CT6904A-1
Rated current: 500 A AC/DC | Max. allowable input: Within the derating range, However, up to ±1000 A peak is allowable if within 20 ms. (design value) | Frequency bandwidth: Amplitude: DC to 4 MHz (CT6904A), DC t...
Nagano, JapónAC/DC CURRENT SENSOR CT6876A
Rated current: 1000 A AC/DC | Max. allowable input: Within the derating range, up to ±1800 Apeak (design value) allowed at 40°C or less for 20 ms or less | Frequency bandwidth: Amplitude: DC to 1.5 MHz (CT6876A),...
Nagano, JapónAC/DC CURRENT SENSOR CT6875A
Rated current: 500 A AC/DC | Max. allowable input: Within the derating range, up to ±1500 Apeak (design value) allowed at 40°C or less for 20 ms or less | Frequency bandwidth: Amplitude: DC to 2 MHz (CT6875A), DC...
Nagano, Japón