AC/DC CURRENT SENSOR CT6875A en Nagano, Japón

Especificaciones

Condición
nuevo
Rated current
500 A AC/DC
Max. allowable input
Within the derating range, up to ±1500 Apeak (design value) allowed at 40°C or less for 20 ms or less
Frequency bandwidth
Amplitude: DC to 2 MHz (CT6875A), DC to 1.5 MHz (CT6875A-1) Phase: DC to 1 MHz
Basic accuracy
(DC, 45 Hz ≤ f ≤ 66 Hz) Amplitude: ±0.04 % rdg. ±0.008 % f.s., Phase: ±0.08°
Output voltage rate
4 mV / A rated (This device outputs AC+DC voltage via the Sensor Unit)
Max. rated voltage to earth
1000 V AC/DC (50/60 Hz, CAT III )
Core diameter
φ 36 mm (1.42 in)
Operating temperature, humidity
-40°C to +85°C (-40°F to 185°F), 80% RH or less (with no condensation)
Power supply
Power suppled via the Power Analyzer PW8001, PW6001, PW3390, Sensor Unit CT9555, CT9556, CT9557, or 3CH CURRENT UNIT U8977
Max. rated power
7 VA max. (at 500 A/55 Hz)
Dimensions and mass
160 mm (6.30 in)W × 112 mm (4.41 in)H × 50 mm (1.97 in)D, CT6875A: 850 g (30 oz), cable length 3 m (9.84 ft), CT6875A-1: 1150 g (40.6 oz), cable length 10 m (32.81 ft)
Included accessories
Instruction Manual ×1, Mark bands ×6, Operating Precautions ×1
Compatible models
CT6875A
Power analyzer pw8001, pw6001, pw3390
Ok
Power analyzer 3390
Attention (Requires CT9901)
Power hitester 3193 series
Attention (Requires CT9901)
Current unit 8971
Attention (Requires the 9318, CT9901)
ID de Anuncio
64598557

Descripción

Hioki's pass-through type AC/DC current sensors can be connected directly to Hioki Power Analyzers and Memory HiCorders. Also, it can be connected to Power Meters, Oscilloscopes, DMMs, etc. by using an optional sensor unit.
The CT6875A has a frequency bandwidth of DC to 2 MHz (Model CT6875A-1 is DC to 1.5 MHz) and a rated current of 500 A. It is used for R&D, quality evaluation, manufacturing, and maintenance in markets such as wireless charging systems, inverter motors for industrial equipment, power conditioners for PV, and quick charging facilities for EVs.
Use with an instrument with a high input impedance of 1 MΩ or higher.
Combined accuracy with HIOKI power analyzer PW8001, PW6001 and PW3390 is specified. For details of combined accuracy, refer to the instruction manual.
Strengthened shield improves noise resistance to accurately measure current buried in noise

Flat frequency characteristics and CMRR performance to achieve high accuracy measurement

Contactar al vendedor

Fabricante
N/A
Ubicación
🇯🇵 Nagano, Japón

¿Le interesa esta máquina?

Capacidad de respuesta del vendedor:

4.75