Building Filters
IMPEDANCE ANALYZER IM3570
Measurement modes: LCR mode, Analyzer mode (Sweeps with measurement frequency and measurement level), Continuous measurement mode | Measurement parameters: Z, Y, θ, Rs (ESR), Rp, Rdc (DC resistance), X, G, B, Cs,...
Nagano, JapónCHEMICAL IMPEDANCE ANALYZER IM3590
Measurement modes: LCR mode, Continuous measurement mode (LCR mode / Analyzer mode), Analyzer mode (Sweeps with measurement frequency and measurement level, temperature characteristics, equivalent circuit analysi...
Nagano, JapónIMPEDANCE ANALYZER IM7587
Measurement modes: LCR mode, Analyzer mode (sweeps with measurement frequency and measurement level), Continuous measurement mode | Measurement parameters: Z, Y, θ, Rs (ESR), Rp, X, G, B, Cs, Cp, Ls, Lp, D (tanδ...
Nagano, JapónIMPEDANCE ANALYZER IM7580A
Measurement modes: LCR mode, Analyzer mode (Sweeps with measurement frequency and measurement level), Continuous measurement mode | Measurement parameters: Z, Y, θ, Rs (ESR), Rp, X, G, B, Cs, Cp, Ls, Lp, D (tanδ...
Nagano, JapónIMPEDANCE ANALYZER IM7581
Measurement modes: LCR mode, Analyzer mode (Sweeps with measurement frequency and measurement level), Continuous measurement mode | Measurement parameters: Z, Y, θ, Rs (ESR), Rp, X, G, B, Cs, Cp, Ls, Lp, D (tanδ...
Nagano, JapónIMPEDANCE ANALYZER IM7585
Measurement modes: LCR mode, Analyzer mode (sweeps with measurement frequency and measurement level), Continuous measurement mode | Measurement parameters: Z, Y, θ, Rs (ESR), Rp, X, G, B, Cs, Cp, Ls, Lp, D (tanδ...
Nagano, JapónIMPEDANCE ANALYZER IM7583
Measurement modes: LCR mode, Analyzer mode (Sweeps with measurement frequency and measurement level), Continuous measurement mode | Measurement parameters: Z, Y, θ, Rs (ESR), Rp, X, G, B, Cs, Cp, Ls, Lp, D (tanδ...
Nagano, JapónINSULATION TESTER IR4057-50
- Fabricante: HIOKI E.E
Rated output voltage: 50 V DC | Effective maximum indicated value: 100 MΩ | Accuracy 1st effective measuring range mω: ±2 % rdg. ±2 dgt. 0.200 - 10.00 | Lower limit resistance: 0.05 MΩ | Overload protection: 600...
Nagano, JapónINSULATION TESTER IR4056
- Fabricante: HIOKI E.E
Rated output voltage: 50 V DC | Effective maximum indicated value: 100 MΩ | Accuracy 1st effective measuring range mω: ±2 % rdg. ±2 dgt. 0.200 - 10.00 | Lower limit resistance: 0.05 MΩ | Overload protection: 600...
Nagano, JapónAC CLAMP POWER METER CM3286-50
Measurement line: Single-phase, Three-phase (balanced with no distortion) | Measurement items: Voltage, Current, Voltage/Current peak, Active/Reactive/Apparent power, Power factor, Phase angle (*1), Frequency, Si...
Nagano, JapónDIGITAL MULTIMETER DT4255
Dc voltage range: 600.0 mV to 1000 V 5 ranges, Basic accuracy: ±0.3 % rdg. ±3 dgt. | Ac voltage range: 6.000 V to 1000 V, 4 ranges, Frequency characteristics: 40 Hz to 1 kHz Basic accuracy 40 - 500 Hz : ±0.9 % rd...
Nagano, JapónDIGITAL MULTIMETER DT4252
Dc voltage range: 600.0 mV to 1000 V, 5 ranges Basic accuracy: ±0.3 % rdg. ±5 dgt. | Ac voltage range: 6.000 V to 1000 V, 4 ranges, Frequency characteristics: 40 Hz - 1 kHz Basic accuracy 40 - 500 Hz : ±0.9 % rdg...
Nagano, JapónDIGITAL MULTIMETER DT4253
Dc voltage range: 600.0 mV to 1000 V 5 ranges, Basic accuracy: ±0.3 % rdg. ±5 dgt. | Ac voltage range: 6.000 V to 1000 V, 4 ranges, Frequency characteristics: 40 Hz to 1 kHz Basic accuracy 40 - 500 Hz : ±0.9 % rd...
Nagano, JapónMAGNETIC FIELD HiTESTER FT3470-51
Magnetic flux density (bandwidth): 10 Hz to 400 kHz/ 10 Hz to 2 kHz/ 2 kHz to 400 kHz | Exposure level: General public/ Occupational | Display: Single axes X, Y, Z (2000 counts), Composite RMS value R (3464 count...
Nagano, JapónPOWER QUALITY ANALYZER PQ3198
Measurement line type: Single-phase 2-wire, Single-phase 3-wire, Three-phase 3-wire or Three-phase 4-wire plus one extra input channel for voltage, current, power measurement (AC or DC measurement) | Voltage rang...
Nagano, Japón