HORIBA Advanced Techno Co., Ltd. CODA-500
- Fabricante: Horiba
Object: COD concentration in water | Dimensions: 600 (W) mm × 510 (D) mm × 1600 (H) mm* 1 | Mass: Approx. 150 kg | Power source: 100 V to 240 V AC ±10%, 50 Hz/60 Hz | Power consumption: 100 V to 120 V AC: Approx....
Kioto, Japón
Probe UV
- Fabricante: Horiba
Técnica de medición: absorbancia de luz UV | Precisión: +/- 2% en solución estándar | Tiempo de respuesta: 10 sec | compensación de turbidez: Integrado por método de doble haz | Fuente de luz vida útil: > 5 años...
Kioto, Japón
UV500
Sample flow: Recommended : 0 - 5 L/MIN 0 – 0.5 l/min for NH4 or H2S | Sample pressure: 0 – 4 Bar (0 - 1 Bar with sampling peristaltic pump) 0 – 0.5 Bar for NH4 or H2S | Sample temperature: 0 °C to 80 °C 0°C to 30...
Kioto, Japón
HORIBA Advanced Techno Co., Ltd. TPNA-500
- Fabricante: Horiba
Dimensions *1: 460 (W) mm × 385 (D) mm × 1600 (H) mm | Mass: Approx. 87 kg | Power supply: 100 V to 240 V AC ±10%, 50 Hz/60 Hz | Power consumption: 100 V to 240 V AC: Approx. 250 VA | Repeatability: Within ±3% of...
Kioto, Japón
HORIBA Advanced Techno Co., Ltd. HD-300
- Fabricante: Horiba
Product name: Dissolved oxygen meter | Combined sensor: 5505, 5510 (A bipolar diaphragm type polarography sensor) | Combined probe: DO-1100 | Saturation degree: 1% | Temperature: 0.1℃ | Linearity: Within ±0.08 mA...
Kioto, Japón
UV500 ATEX
Sample flow: Recommended : 0 - 5 L/MIN 0 – 0.5 l/min for NH4 or H2S | Sample pressure: 0 - 4 Bar (0 - 1 Bar with sampling peristaltic pump) 0 - 0.5 Bar for NH4 or H2S | Sample temperature: 0 °C to 80 °C 0 - 30 °C...
Kioto, Japón
HORIBA Advanced Techno Co., Ltd. OPSA-150
- Fabricante: Horiba
Product name: Organic Pollutant Monitor (UV meter) | Measurement item: UV absorbance, VIS absorbance, COD conversion concentration, TURB (turbidity) conversion concentration | Measurement principle: Dual optical ...
Kioto, Japón
HORIBA Advanced Techno Co., Ltd. HE-300R
- Fabricante: Horiba
Product name: Resistivity meter | Sensors in combination: 2-electrode method resistivity sensor (ERF-001 Series) of cell constant 0.01/cm | Temperature: Comparison to the accurate thermometer Both deviation and c...
Kioto, Japón
HORIBA Advanced Techno Co., Ltd. HE-200R
- Fabricante: Horiba
Product name: Resistivity meter | Combined sensor: 2-electrode method resistivity sensor (ERF-001 Series) of cell constant 0.01/cm | Temperature: Comparison to the accurate thermometer Both deviation and coeffici...
Kioto, Japón
HORIBA Advanced Techno Co., Ltd. HE-200H
- Fabricante: Horiba
Product name: Conductivity meter | Sensors in combination: 4-electrode method conductivity sensor (FES Series) of cell constant 0.1/cm, or 1.0/cm | Display range: 0.0 to 220.0 | Temperature: 0.01℃ | Nacl: 0.0% to...
Kioto, Japón
HORIBA Advanced Techno Co., Ltd. HE-200C
- Fabricante: Horiba
Product name: Conductivity meter | Sensors in combination: 2-electrode method conductivity sensor ESH, ESD, ESL, and FS Series sensor of cell constant 0.01/cm,0.1/cm, or 1.0/cm | Temperature: 0.01℃ | Linearity: W...
Kioto, Japón
HORIBA Advanced Techno Co., Ltd. HC-200F
- Fabricante: Horiba
Product name: Fluoride ion meter | Electrode used with product: Fluoride ion electrode | Temperature: 0.1℃ | Linearity: Within ±0.08 mA (output only) | Output type: Contact output with voltage (output of connecte...
Kioto, Japón
HORIBA, Ltd. 51 series
- Fabricante: Horiba
Measuring principle: Non-Dispersive Infrared Absorption Method (NDIR) | Component: CO, CO 2 , CH 4 , etc. *1 | Span ±0.5% of full scale: Span : ±1.0% of full scale | Linearity: ±1.0% of full scale | Optional ran...
Kioto, Japón
HORIBA Advanced Techno Co., Ltd. CS-600F
- Fabricante: Horiba
Measurement principle: Absorption spectroscopic method | Calculation principle: Temperature compensation type multivariate analysis | Measurement target: NH 3 /H 2 O 2 /H 2 O (reperesentative specification) * Ple...
Kioto, Japón
HORIBA Advanced Techno Co., Ltd. CS-100F1 Series
- Fabricante: Horiba
Measurement principle: Absorption spectrometry | Concentration computation principle: Temperature-compensated multivariate analysis | Sample solution temperature: 20 to 80: (when using Inline cell) 20 to 30: (whe...
Kioto, Japón