Building Filters
GF1060 Laboratory Current Transformer Test System
Accuracy class: ±3% +0.025VA | Standard current measurement range: 1% ~120% In, 0.05% RD (In=1A or In=5A) | Tested current measurement range: 1% ~120% In, 0.05% RD (In=1A, In=5A) | Tested small signal input volta...
Pekín, ChinaT-213S Three Phase Transformer Dc Resistance Test Equipment
Power supply: Single phase AC 220V±10% or 110V±10% , 50/60HzAC | Cooling way: Intermittent air cooled | Single channel current output: 1A, 5A, 10A, 20A | Three channel current output: 1A+1A, 5A+5A, 10A+10A | Test...
Pekín, ChinaGf1060M Miniature Current Transformer Test Equipment
Accuracy class: Ratio error | Power supply: Single phase AC 220V±10% or 110V±10% , frequency 50/60Hz | Range: 0.2A, 1A, 5A | Adjustment range: (0-120)%RG | Adjust fineness: 0.01%RG | Accuracy: 0.05% RD | Stabilit...
Pekín, ChinaT-218 Automatic Portable Transformer Demagnetization Tester
Suministro de energía: AC monofásico 220V±10% o 110V±10%, 50/60Hz AC | Forma de refrigeración: Enfriado por aire intermitente | Salida de corriente: 200 mA, 1 A, 5 A (10 A, 20 A, 50 A opcional) | Lcd: Pantalla TF...
Pekín, ChinaT-213 Transformer winding DC resistance tester
Power supply: Single phase AC 220V±10% or 110V±10% , 50/60Hz AC | Cooling way: Intermittent air cooled | Current output: 10mA, 100mA, 1A, 5A, 10A, 20A | Test voltage: DC 28V | Test range: 1mΩ-1Ω (20A) | Accuracy:...
Pekín, ChinaTEST-200 200A portable primary current injection test kit
Accuracy: <0.2% | Power supply(ac): 220V±10% 2000VA, 50Hz/60Hz or 110V±10% 2000VA, 50Hz/60Hz | Current output (ac): 200A·5V or 100A·10V | Capacity: 2KVA | The current output waveform distortion: ≤5% | Dual protec...
Pekín, ChinaTEST-903 electrical 3000A primary current injection test equipment
Precisión: <0,2% ±5 palabras | Fuente de alimentación (ca): 380V±10% 50A, 50Hz/60Hz | Salida de corriente (ca): 3000A·5V o 1500A·10V | Capacidad: 15KVA | La distorsión de la forma de onda de salida de corriente: ...
Pekín, ChinaTEST-901 large current 1000a primary current injection test set
Accuracy: <0.2% ±2words | Power supply (ac): 220V±10% 25A, 50Hz/60Hz or 110V±10% 50A, 50Hz/60Hz | Current output (ac): 1000A·5V or 500A·10V | Capacity: 5KVA | The current output waveform distortion: ≤5% | Dual pr...
Pekín, ChinaGF106FY Current transformer & voltage transformer burden box
Accuracy class: 3 | Rated current: 5A, 1A | Power factor and rated capacity iec60044-1/iec61869-2: COSФ=0.8: 2.5/3.75/5/6.25/7.5/10/12.5/15/20/30/40/50/60VA COSФ=1.0: 2.5/3.75/5/6.25/7.5/10VA | Power factor and r...
Pekín, China- Pekín, China
GF1061PT portable voltage transformer tester
Accuracy: ≤0.05% | Power supply: AC 220V±10% or AC 120V±10% , 50/60Hz or battery | Output voltage: 0-100Vrms | Output current: 0-5Arms (20A peak-value) | Output power: 0-400VA (1500 VApeak) | Automatic frequency ...
Pekín, ChinaGF1061CVT portable capacitor voltage transformer tester
Accuracy: ≤0.05S | Power supply: AC 100-265V, 50/60Hz or battery | Output current: 0-5Arms (20A peak-value) | Output power: 0-400VA (1500 VApeak) | Automatic frequency variation range: 0.1-60Hz | Secondary windin...
Pekín, ChinaGF1061R instrument transformer turns ratio test set
Precisión: 0.05% | Suministro de energía: AC 220V±10% o AC 120V±10%, 50/60Hz | Rango de tensión: 0-100Vrms | Resolución: 0.1V | Gama actual: 0-500mA | Precisión actual: ±1mA, ±0,05% de la lectura ±1 dígito | Razó...
Pekín, ChinaLZCK720-10 resin measuring or protection split core dry type cTs
Normas: IEC60044-1; IEC 61869-2; NTC 2205; ANSI/IEEE C57.13; GB1206-2006; | Clase: PRIX NET, CET ARTICLE NE S'ALLUME PAS, NOUS NE POUVONS PAS LE TESTER, DÉDUCTION DES PIÈCES OU RÉPARATION GOULD TA11 CONFIGURATIO...
Pekín, ChinaPortable precision current transformer testing ct pt analyzer
Accuracy: ≤0.02% or 0.05% | Power supply: 85-265V AC, 50/60Hz or battery | Output voltage: 0-100Vrms | Output current: 0-5Arms (20A peak-value) | Output power: 0-400VA (1500 VApeak) | Automatic frequency variatio...
Pekín, China