Building Filters
GF1060 Laboratory Current Transformer Test System
Accuracy class: ±3% +0.025VA | Standard current measurement range: 1% ~120% In, 0.05% RD (In=1A or In=5A) | Tested current measurement range: 1% ~120% In, 0.05% RD (In=1A, In=5A) | Tested small signal input volta...
Pekín, ChinaGf1060M Miniature Current Transformer Test Equipment
Accuracy class: Ratio error | Power supply: Single phase AC 220V±10% or 110V±10% , frequency 50/60Hz | Range: 0.2A, 1A, 5A | Adjustment range: (0-120)%RG | Adjust fineness: 0.01%RG | Accuracy: 0.05% RD | Stabilit...
Pekín, ChinaTEST-901 large current 1000a primary current injection test set
Accuracy: <0.2% ±2words | Power supply (ac): 220V±10% 25A, 50Hz/60Hz or 110V±10% 50A, 50Hz/60Hz | Current output (ac): 1000A·5V or 500A·10V | Capacity: 5KVA | The current output waveform distortion: ≤5% | Dual pr...
Pekín, ChinaGF106T portable ct pt analyzer
Accuracy: ≤0.2% | Power supply: AC 220V±10% or AC 110V±10% , 50/60Hz | Excitation voltage output: 0-2500Vrms | Excitation current output: 0-5Arms (20A peak-value) | Large current output: 0-1000A | Large current c...
Pekín, ChinaGF1061CVT portable capacitor voltage transformer tester
Accuracy: ≤0.05S | Power supply: AC 100-265V, 50/60Hz or battery | Output current: 0-5Arms (20A peak-value) | Output power: 0-400VA (1500 VApeak) | Automatic frequency variation range: 0.1-60Hz | Secondary windin...
Pekín, ChinaTEST-200 200A portable primary current injection test kit
Accuracy: <0.2% | Power supply(ac): 220V±10% 2000VA, 50Hz/60Hz or 110V±10% 2000VA, 50Hz/60Hz | Current output (ac): 200A·5V or 100A·10V | Capacity: 2KVA | The current output waveform distortion: ≤5% | Dual protec...
Pekín, ChinaPortable precision current transformer testing ct pt analyzer
Accuracy: ≤0.02% or 0.05% | Power supply: 85-265V AC, 50/60Hz or battery | Output voltage: 0-100Vrms | Output current: 0-5Arms (20A peak-value) | Output power: 0-400VA (1500 VApeak) | Automatic frequency variatio...
Pekín, ChinaGF1061CT Portable ct analyzer with printer
Accuracy: ≤0.02% or 0.05% | Power supply: Single phase AC 85-265V, 50/60Hz or battery | Output current: 0-5Arms (20A peak-value) | Output power: 0-400VA (1500 VApeak) | Automatic frequency variation range: 0.1-60...
Pekín, ChinaGF1061PT portable voltage transformer tester
Accuracy: ≤0.05% | Power supply: AC 220V±10% or AC 120V±10% , 50/60Hz or battery | Output voltage: 0-100Vrms | Output current: 0-5Arms (20A peak-value) | Output power: 0-400VA (1500 VApeak) | Automatic frequency ...
Pekín, China