Building Filters
LUX METER FT3424
Standards: DIN 5032-7: 1985 class B, JIS C 1609-1: 2006 general AA class | Light receiving element: Silicon photo diode | Range selection: Auto/ Manual | Linearity: ±2% rdg. (Multiply by 1.5 for display values i...
Nagano, JapónLUX METER FT3425
Standards: DIN 5032-7: 1985 class B, JIS C 1609-1: 2006 general AA class | Light receiving element: Silicon photo diode | Range selection: Auto/ Manual | Linearity: ±2% rdg. (Multiply by 1.5 for display values i...
Nagano, JapónPOWER MEASUREMENT MODULE M7103
Compatible models: Data Logger LR8101: Standard model Data Logger LR8102: Advanced model | Operating temperature and humidity range: 0°C to 40°C (32°F to 104°F), 80% RH or less (non-condensing) | Measurement line...
Nagano, JapónAC CLAMP METER CM3291
Ac current range: 42.00 to 2000 A, 3 ranges (40 Hz to 1 kHz, True RMS), Basic accuracy 45-66 Hz: ±1.5% rdg. ±5 dgt. | Dc voltage range: 420.0 mV to 600 V, 5 ranges, Basic accuracy: ±1.0 % rdg. ±3 dgt. (at 4.2 V ...
Nagano, JapónAC CLAMP METER 3280-10F
Ac current range: 41.99 to 1000 A, 3 ranges (50 Hz to 60 Hz, Average rectified), Basic accuracy: ±1.5 % rdg. ±5 dgt. | Dc voltage range: 419.9 mV to 600 V, 5 ranges, Basic accuracy: ±1.0 % rdg. ±3 dgt. | Ac volt...
Nagano, JapónAC CLAMP METER CM3281
Ac current range: 42.00 to 2000 A, 3 ranges (50 Hz to 60 Hz, Average rectified), Basic accuracy 50-60 Hz: ±1.5% rdg. ±5 dgt. | Dc voltage range: 420.0 mV to 600 V, 5 ranges, Basic accuracy: ±1.0 % rdg. ±3 dgt. (...
Nagano, JapónAC/DC CURRENT SENSOR CT6863-05
Rated current: 200 A AC/DC | Max. allowable input: 400 A rms (requires derating) | Frequency characteristics: Amplitude: DC to 500 kHz Phase: DC to 300 kHz | Amplitude and phase accuracy: DC ±0.05 % rdg. ±0.01 % ...
Nagano, JapónAC/DC CURRENT SENSOR CT6862-05
Rated current: 50 A AC/DC | Max. allowable input: Within the derating range, up to ±150 A peak (design value) allowed at 40°C or less for 20 ms or less | Frequency bandwidth: Amplitude: DC to 10 MHz Phase: DC to ...
Nagano, JapónCLAMP ON SENSOR 9669
Rated measurement current: 1000 A AC | Max. measurement current: Continuous 1000 A (45 to 66 Hz) | Output rate: 0.5 mV AC/ A | Amplitude accuracy (45 to 66 hz): ±1.0% rdg. ±0.01% f.s. | Phase accuracy: ±1° (45 ...
Nagano, JapónCLAMP ON SENSOR 9661
Rated measurement current: 500 A AC | Max. measurement current: Continuous 550 A (45 to 66 Hz) | Output rate: 1 mV AC/ A | Amplitude accuracy (45 to 66 hz): ±0.3% rdg. ±0.01% f.s. | Phase accuracy: ±0.5° (45 Hz...
Nagano, JapónCLAMP ON SENSOR 9660
Rated measurement current: 100 A AC | Max. measurement current: Continuous 130 A (45 to 66 Hz) | Output rate: 1 mV AC/ A | Amplitude accuracy (45 to 66 hz): ±0.3 % rdg. ±0.02 % f.s. | Phase accuracy: ±1° (45 Hz...
Nagano, JapónCLAMP ON SENSOR 9694
Rated measurement current: 5 A AC | Max. measurement current: Continuous 50 A (45 to 66 Hz) | Output rate: 10 mV AC/ A | Amplitude accuracy (45 to 66 hz): ±0.3 % rdg. ±0.02 % f.s. | Phase accuracy: ±2° (45 Hz t...
Nagano, JapónCLAMP ON SENSOR 9695-02
Rated measurement current: 50 A AC | Max. measurement current: Continuous 60 A (45 to 66 Hz) | Output rate: 10 mV AC/ A | Amplitude accuracy (45 to 66 hz): ±0.3 % rdg. ±0.02 % f.s. (*1) | Phase accuracy: ±2° (4...
Nagano, JapónSENSOR UNIT CT9555
Connectable current sensors: Current sensors with a Hioki ME15W (male) output connector (CT686x-05, 9709-05, CT684x-05, etc.) *The separately available Conversion Cable CT9900 is required in order to use a curren...
Nagano, JapónCLAMP ON SENSOR 9695-03
Rated measurement current: 100 A AC | Max. measurement current: Continuous 130 A (45 to 66 Hz) | Output rate: 1 mV AC/ A | Amplitude accuracy (45 to 66 hz): ±0.3 % rdg. ±0.02 % f.s. (*1) | Phase accuracy: ±1° (...
Nagano, Japón