AC/DC CURRENT PROBE CT6843A
Rated current: 200 A AC/DC | Frequency bandwidth: DC to 700 kHz | Diameter of measurable conductors: Max. φ 20 mm (0.79 in.) | Max. allowable input: ±600 A peak (Within 20 ms in an environment of 40°C/104°F or le...
Nagano, JapónAC/DC CURRENT PROBE CT6845A
Rated current: 500 A AC/DC | Frequency bandwidth: DC to 200 kHz | Diameter of measurable conductors: Max. φ 50 mm (1.97 in.) | Max. allowable input: ±1500 A peak (Within 20 ms in an environment of 40°C/104°F or ...
Nagano, JapónAC/DC CURRENT PROBE CT6846A
Rated current: 1000 A AC/DC | Frequency bandwidth: DC to 100 kHz | Diameter of measurable conductors: Max. φ 50 mm (1.97 in.) | Max. allowable input: ±1900 Apeak (Within 20 ms in an environment of 40°C/104°F or l...
Nagano, JapónAC/DC CURRENT SENSOR CT6872
Rated current: 50 A AC/DC | Max. allowable input: Within the derating range, up to ±150 A peak (design value) allowed at 40°C or less for 20 ms or less | Frequency bandwidth: Amplitude: DC to 10 MHz Phase: DC to ...
Nagano, JapónAC/DC CURRENT SENSOR CT6904A-2, CT6904A-3
Rated current: 800 A AC/DC | Max. allowable input: Within the derating range, However, up to ±1200 A peak is allowable if within 20 ms. (design value) | Frequency bandwidth: Amplitude: DC to 4 MHz (CT6904A-2), DC...
Nagano, JapónAC/DC CURRENT SENSOR CT6873
Rated current: 200 A AC/DC | Max. allowable input: Within the derating range, up to ±420 A peak (design value) allowed at 40°C or less for 20 ms or less | Frequency bandwidth: Amplitude: DC to 10 MHz Phase: DC to...
Nagano, JapónDIGITAL MULTIMETER DT4256
Dc voltage range: 600.0 mV to 1000 V, 5 ranges Basic accuracy: ±0.3 % rdg. ±3 dgt. | Ac voltage range: 6.000 V to 1000 V, 4 ranges, Frequency characteristics: 40 Hz to 1 kHz Basic accuracy 40 - 500 Hz : ±0.9 % rd...
Nagano, JapónDIGITAL MULTIMETER DT4252
Dc voltage range: 600.0 mV to 1000 V, 5 ranges Basic accuracy: ±0.3 % rdg. ±5 dgt. | Ac voltage range: 6.000 V to 1000 V, 4 ranges, Frequency characteristics: 40 Hz - 1 kHz Basic accuracy 40 - 500 Hz : ±0.9 % rdg...
Nagano, JapónCLAMP ON PROBE 9018-50
Rated current: 10 A to 500 A AC, 6 ranges | Accuracy: ±1.5% rdg. ±0.1% f.s. (45 to 66 Hz) | Frequency characteristics: Add to amplitude accuracy : ± 1% rdg. Add to phase accuracy : ± 2.5° for frequencies from 40 ...
Nagano, JapónAC/DC CURRENT PROBE CT6841A
Rated current: 20 A AC/DC | Frequency bandwidth: DC to 2 MHz | Diameter of measurable conductors: Max. φ 20 mm (0.79 in.) | Max. allowable input: ±60 A peak (Within 20 ms in an environment of 40°C/104°F or less)...
Nagano, JapónAC/DC CURRENT PROBE CT6844A
Rated current: 500 A AC/DC | Frequency bandwidth: DC to 500 kHz | Diameter of measurable conductors: Max. φ 20 mm (0.79 in.) | Max. allowable input: ±800 A peak (Within 20 ms in an environment of 40°C/104°F or le...
Nagano, JapónAC/DC CURRENT SENSOR CT6877A
Rated current: 2000 A AC/DC | Max. allowable input: Within the derating range, (within the specified range up to ±3200 Apeak ) | Frequency characteristics: Amplitude: DC to 1 MHz, Phase: DC to 700 kHz | Basic acc...
Nagano, JapónCARD HiTESTER 3244-60
Dc voltage range: 419.9 mV to 500 V, 5 ranges, Basic accuracy: ±0.7 % rdg. ±4 dgt. | Ac voltage range: 4.199 V to 500 V, 4 ranges, Basic accuracy 50 - 500 Hz : ±2.3 % rdg. ±8 dgt. (Average rectified) | Resistanc...
Nagano, JapónPENCIL HiTESTER 3246-60
Dc voltage range: 419.9 mV to 600 V, 5 ranges, Basic accuracy: ±1.3 % rdg. ±4 dgt. | Ac voltage range: 4.199 V to 600 V, 4 ranges, Basic accuracy 50 - 500 Hz : ±2.3 % rdg. ±8 dgt. (Average rectified) | Resistance...
Nagano, JapónDIGITAL MULTIMETER DT4253
Dc voltage range: 600.0 mV to 1000 V 5 ranges, Basic accuracy: ±0.3 % rdg. ±5 dgt. | Ac voltage range: 6.000 V to 1000 V, 4 ranges, Frequency characteristics: 40 Hz to 1 kHz Basic accuracy 40 - 500 Hz : ±0.9 % rd...
Nagano, Japón