Building Filters
Portable precision current transformer testing ct pt analyzer
Accuracy: ≤0.02% or 0.05% | Power supply: 85-265V AC, 50/60Hz or battery | Output voltage: 0-100Vrms | Output current: 0-5Arms (20A peak-value) | Output power: 0-400VA (1500 VApeak) | Automatic frequency variatio...
Pekín, ChinaGF1061CT Portable ct analyzer with printer
Accuracy: ≤0.02% or 0.05% | Power supply: Single phase AC 85-265V, 50/60Hz or battery | Output current: 0-5Arms (20A peak-value) | Output power: 0-400VA (1500 VApeak) | Automatic frequency variation range: 0.1-60...
Pekín, ChinaGF1061PT portable voltage transformer tester
Accuracy: ≤0.05% | Power supply: AC 220V±10% or AC 120V±10% , 50/60Hz or battery | Output voltage: 0-100Vrms | Output current: 0-5Arms (20A peak-value) | Output power: 0-400VA (1500 VApeak) | Automatic frequency ...
Pekín, ChinaGF106T portable ct pt analyzer
Accuracy: ≤0.2% | Power supply: AC 220V±10% or AC 110V±10% , 50/60Hz | Excitation voltage output: 0-2500Vrms | Excitation current output: 0-5Arms (20A peak-value) | Large current output: 0-1000A | Large current c...
Pekín, ChinaGF1061CVT portable capacitor voltage transformer tester
Accuracy: ≤0.05S | Power supply: AC 100-265V, 50/60Hz or battery | Output current: 0-5Arms (20A peak-value) | Output power: 0-400VA (1500 VApeak) | Automatic frequency variation range: 0.1-60Hz | Secondary windin...
Pekín, ChinaGF1060 Laboratory Current Transformer Test System
Accuracy class: ±3% +0.025VA | Standard current measurement range: 1% ~120% In, 0.05% RD (In=1A or In=5A) | Tested current measurement range: 1% ~120% In, 0.05% RD (In=1A, In=5A) | Tested small signal input volta...
Pekín, ChinaGf1060M Miniature Current Transformer Test Equipment
Accuracy class: Ratio error | Power supply: Single phase AC 220V±10% or 110V±10% , frequency 50/60Hz | Range: 0.2A, 1A, 5A | Adjustment range: (0-120)%RG | Adjust fineness: 0.01%RG | Accuracy: 0.05% RD | Stabilit...
Pekín, ChinaGF106FY Current transformer & voltage transformer burden box
Accuracy class: 3 | Rated current: 5A, 1A | Power factor and rated capacity iec60044-1/iec61869-2: COSФ=0.8: 2.5/3.75/5/6.25/7.5/10/12.5/15/20/30/40/50/60VA COSФ=1.0: 2.5/3.75/5/6.25/7.5/10VA | Power factor and r...
Pekín, ChinaLZCK310-10 400/5a cheap split core cast resin current transformer
Standards: IEC60044-1; IEC 61869-2; NTC 2205; ANSI C57.13; GB1208-2006; | Class: 0.5, 1, 3 | Rated primary current: 300-1000A | Rated secondary current: 5A or 1A | Rated load: ≤10VA | Rated frequency: 50Hz or 60H...
Pekín, ChinaLZCK720-10 resin measuring or protection split core dry type cTs
Standards: IEC60044-1; IEC 61869-2; NTC 2205; ANSI/IEEE C57.13; GB1206-2006; | Class: 0.5, 1, 3, 10P10, 10P5 | Rated primary current: 100-1500A | Rated load: ≤15VA | Rated frequency: 50Hz or 60Hz | Rated secondar...
Pekín, ChinaLZCT722-10 electrical cast resin zct zero sequence current transformer
Standards: IEC60044-1; IEC 61869-2; NTC 2205; ANSI/IEEE C57.13; GB1206-2006; | Class: 0.2S, 0.2, 0.5S, 0.5, 1, 3, 10P10, 10P, 10P20 | Rated primary current: 50-1500A | Rated load: ≤25VA | Rated frequency: 50Hz or...
Pekín, ChinaLZCK322-10 11KV 33KV high voltage split core CT current transformer
Standards: IEC60044-1; IEC 61869-2; NTC 2205; ANSI C57.13; GB1208-2006; | Class: 0.5, 1, 3 | Rated primary current: 30-1000A | Rated load: ≤15VA | Rated frequency: 50Hz or 60Hz | Rated secondary current: 5A or 1A...
Pekín, ChinaS150 Large Jaw Cable Fault Location Supermalloy Current Transformer Clamp
Ratio: 10001, 2005 or... 30005 (customized) | Accuracy class: 0.1%, 0.2%, 0.5% | Primary current: 0-3000A AC | Secondary current: 0-1A or 0-5A AC (customized) | Secondary voltage: 0-1V, 0-5V AC (customized) | Max...
Pekín, ChinaLZCK2500-10 high accuracy 33KV split core zero phase current transformer
Standards: IEC60044-1; IEC 61869-2; NTC 2205; ANSI/IEEE C57.13; GB1206-2006; | Class: 0.5, 1, 3, 10P10, 10P5, 10P20 | Rated primary current: 50-2000A | Rated load: ≤25VA | Rated frequency: 50Hz or 60Hz | Rated se...
Pekín, ChinaLZCG930-10 cheap low voltage cast resin ring core current transformer
Standards: IEC60044-1; IEC 61869-2; NTC 2205; ANSI/IEEE C57.13; GB1206-2006; | Accuracy class: 0.2S, 0.2, 0.5S, 0.5 (IEC61869-2 standard) | Rated primary current: 30-1000A | Rated load: ≤30VA | Rated frequency: 5...
Pekín, China