Building Filters
Yamato DHS710
- Fabricante: Yamato
Method: Forced convection and ventilation | Operating temperature range: Room temp.+15~360℃ | Max. temp. reaching time: Approx. 50 min.(at 360℃) | Temperature adjustment accuracy: ±0.3℃(at 360℃) | Temperature dis...
Tokio, JapónYamato DFS810
- Fabricante: Yamato
Method: Forced convection and ventilation | Operating temperature range: Room temp.+15~260℃ | Max. temp. reaching time: Approx. 40 min.(at 260℃) | Temperature adjustment accuracy: ±0.2℃(at 260℃) | Temperature dis...
Tokio, JapónYamato DFS710
- Fabricante: Yamato
Method: Forced convection and ventilation | Operating temperature range: Room temp.+15~260℃ | Max. temp. reaching time: Approx. 40 min.(at 260℃) | Temperature adjustment accuracy: ±0.2℃(at 260℃) | Temperature dis...
Tokio, JapónYamato CLS302
- Fabricante: Yamato
Method: External opened circulation | Operating temperature range: -10°C to RT | Temperature control accuracy: ±1.5 to ±2°C | Cooling capacity: Approx. 450W(387Kcal/h), at fluid temp. 15°C | Temperature control: ...
Tokio, JapónHORIBA Advanced Techno Co., Ltd. 5700A
- Fabricante: Horiba
Measuring method: Optical (fluorescent) | Measuring range: DO: 0 to 20 mg/L Resolution: 0.01 mg/L Saturation: 0 to 200% Resolution: 0.1% Temperature: 0 to 50°C Resolution: 0.1°C | Transmission output: 2...
Kioto, JapónYamato CLH610
- Fabricante: Yamato
Method: External opened circulation | Operating temperature range: -15 to +80°C | Temperature control accuracy: ±0.1°C (JTM K05) at fluid temp.10°C | Cooling capacity: Approx. 785W (676 Kcal/h), at fluid temp.15°...
Tokio, JapónYamato CLH302
- Fabricante: Yamato
Method: External opened circulation | Operating temperature range: -10 to +80°C | Temperature control accuracy: ±0.1°C (JTM K05) at fluid temp.10°C | Cooling capacity: Approx. 450W (387Kcal/h), at fluid temp.15°C...
Tokio, JapónYamato CLH401
- Fabricante: Yamato
Method: External opened circulation | Operating temperature range: -15 to +80°C | Temperature control accuracy: 0.2°C (JTM K05/JIS) at fluid temp.10°C | Cooling capacity: Approx. 600W (517 Kcal/h), at fluid temp....
Tokio, JapónHORIBA Advanced Techno Co., Ltd. HR-480
- Fabricante: Horiba
Product name: Industrial Residual Chlorine Meter | Measurement method: Galvanic cell method | Repeatability: Within ±0.05 mg/L (with equivalent input) | Linearity: Within ±0.05 mg/L (with equivalent input) | Tran...
Kioto, JapónHORIBA Advanced Techno Co., Ltd. HE-960HI
- Fabricante: Horiba
Product name: Conductivity meter | Measuring method: Four-electrode type | Cell constant: 0.1/cm | Temperature sensor specifications: Resistance thermometer bulb 1000 Ω/0℃ | Temperature: −30℃ to 160℃ | Naoh: 0% t...
Kioto, JapónHORIBA Advanced Techno Co., Ltd. HC-200F
- Fabricante: Horiba
Product name: Fluoride ion meter | Electrode used with product: Fluoride ion electrode | Temperature: 0.1℃ | Linearity: Within ±0.08 mA (output only) | Output type: Contact output with voltage (output of connecte...
Kioto, JapónYamato FO610
- Fabricante: Yamato
Operating temp. range: 100 to 1,150℃ | Temp. control accuracy: ±2.0℃(at 1,150℃) | Max. temp. reaching time: Approx. 80min. | Exterior material: Cold rolled steel plate with baked-on melamine resin finish | Intern...
Tokio, JapónYamato FO810
- Fabricante: Yamato
Operating temp. range: 100 to 1,150℃ | Temp. control accuracy: ±2.0℃(at 1,150℃) | Max. temp. reaching time: Approx. 80min. | Exterior material: Cold rolled steel plate with baked-on melamine resin finish | Intern...
Tokio, JapónYamato FO510
- Fabricante: Yamato
Operating temp. range: 100 to 1,150℃ | Temp. control accuracy: ±2.0℃(at 1,150℃) | Max. temp. reaching time: Approx. 80min. | Exterior material: Cold rolled steel plate with baked-on melamine resin finish | Intern...
Tokio, JapónHORIBA Advanced Techno Co., Ltd. HP-480
- Fabricante: Horiba
Product name: Industrial pH meter | Measuring range: 0 pH to 14 pH: 0.01 pH resolution. Temperature 0℃ to 100℃: 1℃ resolution (selectable display). | Transmission output: 4 mA to 20 mA DC: input/output isolated t...
Kioto, Japón