FU-32 200/5a indoor clamp on split core current transformer ct
Standards: IEC/EN60044-1 & IEC61010-1 & IEC61869-2&ANSI C57.13 | Ratio: 601, 1201 or 10001, customized | Nominal input current (primary current): 60a/75a/80a/100a/150a/200a/250a/300a/400a/500a/600a | Overload wit...
Pekín, ChinaLZCK-80 Ip68 outdoor waterproof high accuracy 0.5s split core current transformer
Standards: IEC60044-1; IEC 61869-2; NTC 2205; GB1208-2006; GB/T20840.2; ANSI/IEEE C57.13 | Accuracy class: 0.5S, 0.5% , 1% , 3% (IEC61869 standard) | Range of primary rated current: 100-2000A | Range of rated loa...
Pekín, ChinaFU-100 500/5A ring core AC clamp on open current transformer
Standards: IEC/EN60044-1 & IEC61010-1 & IEC61869-2&ANSI C57.13 | Ratio: 601, 1201 or 10001, customized | Nominal input current (primary current): 300A/400A/500A/600A/750A/800A/1000A/1200A/1250A/1500A/2000A/2500A/...
Pekín, China- Cangzhou, China
S120 20K Hz Bandwidth 2000A Clamp On Current Transformer
Ratio: 10001, 20005 or 30005 (customized) | Accuracy class: 0.1%, 0.2%, 0.5% | Primary current: 0-3000A AC | Secondary current: 0-1A or 0-5A AC (customized) | Secondary voltage: 0-2V, 0-5V AC (customized) | Max. ...
Pekín, ChinaCrepe Paper CNC Winding Machine Instrument Transformer Sleeve and Capacitor
1: Ancho de papel crepé 50 mm El comprador proporciona muestras durante la prueba | 2: Disco de crepé Rodamiento central: Ф50±2mm Diámetro exterior (máx):<Ф300mm | No: Contenido del artículo | 3: Soporte del cuer...
Pekín, China- Pekín, China
- Pekín, China
Q50A 1000A ratio customized AC clamp on ct current transformer
Ratio: 10001 or 20001 (customized) | Accuracy class: 0.1%, 0.2%, 0.5% | Primary current: 0-1000A AC | Secondary current: 0-1A AC, 0-5A AC (customized) | Max. cont. input current: 1200A | Load capacity: ≤20Ω, stan...
Pekín, China- Pekín, China
T-203H Handheld three phase transformer turns ratio test set
Suministro de energía: batería recargable de litio-íon de 7.2V | Almacenamiento de datos: 500 grupos | Precisión de medición de ttr: Rango1 | Rango2: 3000-10000: 0.2% ±2 palabras | Precisión de la pantalla: 5 bi...
Pekín, China- Pekín, China
TEST-200 200A portable primary current injection test kit
Accuracy: <0.2% | Power supply(ac): 220V±10% 2000VA, 50Hz/60Hz or 110V±10% 2000VA, 50Hz/60Hz | Current output (ac): 200A·5V or 100A·10V | Capacity: 2KVA | The current output waveform distortion: ≤5% | Dual protec...
Pekín, ChinaTEST-901 large current 1000a primary current injection test set
Accuracy: <0.2% ±2words | Power supply (ac): 220V±10% 25A, 50Hz/60Hz or 110V±10% 50A, 50Hz/60Hz | Current output (ac): 1000A·5V or 500A·10V | Capacity: 5KVA | The current output waveform distortion: ≤5% | Dual pr...
Pekín, ChinaLZCK720-10 resin measuring or protection split core dry type cTs
Normas: IEC60044-1; IEC 61869-2; NTC 2205; ANSI/IEEE C57.13; GB1206-2006; | Clase: 0,5, 1, 3, 10P10, 10P5 | Corriente primaria nominal: 100-1500A | Carga nominal: ≤15 VA | Frecuencia nominal: 50 Hz o 60 Hz | Corr...
Pekín, China