AB Sciex TripleTOF 5600+ con Shimadzu Prominence UFLC
- Fabricante: Sciex
Markham, Canadá - Vendedor de confianza

Agilent G6430A Triple Quad LC/MS with 1260/1290 HPLC: G1316C TCC, K1367E HiP ALS Clinical Ed., (2) G1312B SL Bin Pumps, and G1379B Micro Degasser
- Fabricante: Agilent - Keysight
- Modelo: 6430A
Mass range: Up to 2250 m/z | Scan rate: 5,200 u/sec. | Polarity switching: 30 msec. | Minimum dwell time: 1 msec. | Number of mrm: 19,800. | Dynamic mrm: 4,000. | Please note: system includes vacuum pump.
East Lyme, Connecticut - Vendedor de confianza

Waters SYNAPT G2 4K High Definition Mass Spectrometer Model 186004813
- Fabricante: Waters
- Modelo: G2
Tof mass resolution in positive ion: a) Sensitivity Mode 10,000 FWHM measured on the (M + 6H)6+ isotope cluster from bovine insulin (m/z 956) b) Resolution Mode 20,000 FWHM measured on the (M + 6H)6+ isotope cl...
Markham, Canadá 
HORIBA Scientific VS70-PDA-HDR
- Fabricante: Horiba
Spectral coverage: UV-VIS (200–800 nm) with 477 l/mm grating, VIS (280--700 nm) with 582 l/mm grating, UV-NIR (200–985 nm) with double blazed 365 l/mm grating. On request, other spectral ranges available; differe...
Kioto, Japón
HORIBA Scientific PoliSpectra® VS70 Dual & Quad
- Fabricante: Horiba
Feature: Spectroscopy Benefits for OEMs 2-4 channel multi-spectral instruments | Most popular uv-vis-nir range: Excellent peak symmetry in a miniature grating spectrometer | High readout speed: Sub 1.5msec readou...
Kioto, Japón
HORIBA Scientific Raman Spectrometer - MINI-CCT+
- Fabricante: Horiba
Feature: Benefits for Spectroscopy | Raman range with 785 nm: 210 to 2700 cm –1 coverage | High dynamic range: 7000:1 with low readout-noise of 35 e – | Back-illuminated linear ccd: QE=77% at 600nm;55% at 850nm w...
Kioto, Japón
HORIBA Scientific Mini CCT Plus
- Fabricante: Horiba
Feature: Benefits for Spectroscopy | Raman range with 785 nm: 210 to 2700 cm –1 coverage | High dynamic range: 7000:1 with low readout-noise of 35 e – | Back-illuminated linear ccd: QE=77% at 600nm;55% at 850nm w...
Kioto, Japón
Micro Espectrómetro
Píxeles efectivos: 2048×1 | Sensibilidad: 1300 V/(lx·s) | Ruido oscuro: 13 RMS @13*℃ | Resolución óptica: 0.1-3 nm | Interfaz de incidencia: Interfaz de fibra óptica SMA905 o ruta óptica en espacio libre | Rango ...
Xiamen, ChinaEspectrómetro de Plasma de Acoplamiento Inductivo de ICP para la venta
- Fabricante: Gold
After-sales service: Lifetime Technical Support | Personalizado: Personalizado | Estructura: Escritorio | Material: Aluminio | Proceso de dar un título: CE, ISO | Solicitud: Colegio, Laboratorio | Tipo: Inductive...
$100 USDChongqing, China