Building Filters
Scientific-Grade Micro Spectrometer
Detector cooling temperature: ATP6500DC: -70℃ ATP6500EM: -100℃ | Detector type: ATP6500DC: Deep cooling back-thinned CCD ATP6500EM: Deep cooling EMCCD | Spectral range: 180-1100 nm | Effective pixels: ATP6500DC: ...
Xiamen, ChinaHigh-Sensitivity & High-Resolution, TE-Cooled Back-Thinned Spectrometer
Detector type: ATP5200/ATP5200-4: Linear array CCD ATP5200P/ATP5200R: Area array back-thinned CCD | Spectral range: 180-1180 nm | Effective pixels: ATP5200: 2048 ATP5200-4: 4096 ATP5200P/ATP5200R: 2048×...
Xiamen, ChinaScientific grade, ultra-high sensitivity, transmission grating imaging spectrometer
Detector type: ATP6750LT: Deep cooling, Ultra Low Noise Area Array Detector; ATP6750P: UV-Enhanced, Cooled Back-Illuminated Area Array Detector; ATP6750R: Infrared Enhanced, Cooled Back-Illuminated Area Array Det...
Xiamen, ChinaATP8730 High Resolution NIR spectrometer
Detector type: linear array InGaAs CCD,Down to -20ºC | Effective pixels: 1024 | Max dynamic range: >1400 | Max wavelength range: 900-1700nm,Different ranges can be customized | Optical path: f/4 Asymmetric C-T o...
Xiamen, ChinaDeep Cooled NIR Spectrometer
Detector type: Cooled InGaAs Array CCD,Cooled down to-30ºC | Spectral range: 900-1700nm, 900-2100nm, 900-2600 nm, 900-1700HR, 900-2100HR, 900-2500HR (Customized) | Effective pixels: 256/512 | Pixels dimension: 50...
Xiamen, ChinaATP7330 Ultra High Resolution Grating Spectrometer
Detectable range: 180-2500 nm | Effective pixels: CCD: 2048, SWIR InGaAs CCD:512 | Detector model: TE Cooled CCD、TE Cooled InGaAs CCD,Cooled down to -40ºC | Focal distance: 210,350,510 & 760mm | Optical resolutio...
Xiamen, ChinaUV Enhanced Miniature Spectrometer
Detector type: Linear CMOS | Spectral range: 0.2-5 nm (Slit size & spectral range) | Effective pixels: 512 | Sensitivity: 1300V/(lx-s) | Dark noise: 13RMS@13℃ | Pixel size: 14 × 200 μm | Focal distance: 28 mm for...
Xiamen, ChinaATP2400 Micro Spectrometer
Detectable range: 180-1100 nm | Full scale range: ~200 ke- | Pixel dimension: 14μm×200μm | Effective pixels: 2048×1 | Sensitivity: 1300 V/(lx•s) | Dark noise: 0.4 mV RMS | Optical resolution: 0.1-2 nm (Depends on...
Xiamen, ChinaATP5020P micro raman spectrometer
Detector type: 180-1180 nm | Effective pixels: 2048*64 | Detector model: TE-cooled back-illuminated linear array CCD (cooling to -5C) | Sensitivity: 6.5uV/e- | Dark noise: 6e- | Range drift: ~600 ke- | Pixel size...
Xiamen, ChinaATP3334 Uncooled, High Resolution Spectrometer
Detector type: Linear array detector | Effective pixels: 4096 pixels | Pixels dimension: 14μm × 200μm | Sensitivity: 1300 V/(lx·s) | Dark noise: 13 RMS @ 13 ˚C | Range drift: 200-1100 nm | Focal distance: 75mm | ...
Xiamen, ChinaHigh Sensitivity & High Resolution Micro Spectrometer
Detector type: CMOS plus external cooling technology, TE-cooled to -5℃ | Spectral range: 180-1180 nm | Effective pixels: 2048 | Pixels dimension: 14μm×14μm | Full well capacity: 200 Ke- | Sensitivity: 6.5 uV/e- |...
Xiamen, ChinaBest Raman Spectrometer
Detector type: Hamamatsu s16011 | Effective pixels: 2048*64 | Detector model: TE-cooled back-illuminated CCD (cooling to -10C) | Sensitivity: CCD node sensitivity: 6.5uV/e- | Dark noise: CCD Readout Noise:6e- | P...
Xiamen, ChinaMini NIR Spectrometer
Pixels dimension: 256 pixels | Full well capacity: 13.75 Me- | Detector model: Linear InGaAs CCD | Sensitivity: 160 nV/e- | Pixel size: 25μm × 25μm | Dynamic range: 14667 | Working temperature: -10-50℃ | Working ...
Xiamen, ChinaOnline Multi-Channel Fieldspec Spectroradiometer
- Fabricante: Optosky (Xiamen) Photonics
Pixel size: 2048 pixels | Channel rotation cycle: 5s | Length of fiber between probe and controller: 3m, other lengths can be customized, up to 100m | Plant parameter output: Normalized Difference Vegetation Inde...
Xiamen, ChinaATP2000H High Flame Speed
- Fabricante: Optosky (Xiamen) Photonics
Detector type: Linear CMOS | Effective pixels: 2048 | Pixels dimension: 14μm*200μm | Detector model: Hamamatsu S11639 | Sensitivity: 1300v/(lx.s) | Dark noise: 0.4mVrms | Focal distance: 40 mm for incidence / 60 ...
Xiamen, China