Building Filters
Turbidity Sensor
Measurement method: Nephelometric | Measurement range: 0 - 100 NTU (other ranges on request) | Detection limit: 0.015 NTU | Repeatability: +/- 0.01 NTU | Accuracy: +/- 2% or +/- 0.015 NTU whichever is greater up ...
Kioto, JapónYamato SM830 Limited product for overseas
- Fabricante: Yamato
System: Automatic high-pressure steam sterilization | Operating temp. range (sterilization): 105~135℃ | Operating temp. range (drying): 135~150℃ | Max. pressure capacity: 0.255MPa | Operable ambient temp.: 5~35℃ ...
Tokio, JapónYamato SM301 Limited product for overseas
- Fabricante: Yamato
System: Automatic high-pressure steam sterilization | Operating temp. range (sterilization): 105~128℃ | Operating temp. range (drying): 150~180℃ | Max. pressure capacity: 0.2MPa | Safety device: Self-diagnostic f...
Tokio, JapónYamato SM530 Limited product for overseas
- Fabricante: Yamato
System: Automatic high-pressure steam sterilization | Operating temp. range (sterilization): 105~135℃ | Operating temp. range (drying): 135~150℃ | Max. pressure capacity: 0.255MPa | Operable ambient temp.: 5~35℃ ...
Tokio, JapónYamato SM820 Limited product for overseas
- Fabricante: Yamato
System: Automatic high-pressure steam sterilization | Operating temp. range (sterilization): 105~135℃ | Operating temp. range (drying): 135~150℃ | Max. pressure capacity: 0.255MPa | Operable ambient temp.: 5~35℃ ...
Tokio, JapónYamato SM210 Limited product for overseas
- Fabricante: Yamato
System: Automatic high-pressure steam sterilization | Operating temp. range (sterilization): 105~123℃ | Operating temp. range (drying): 150~180℃ | Max. pressure capacity: 0.18MPa | Safety device: Self-diagnostic ...
Tokio, JapónYamato SM520 Limited product for overseas
- Fabricante: Yamato
System: Automatic high-pressure steam sterilization | Operating temp. range (sterilization): 105~135℃ | Operating temp. range (drying): 135~150℃ | Max. pressure capacity: 0.255MPa | Operable ambient temp.: 5~35℃ ...
Tokio, JapónYamato SM511 Limited product for overseas
- Fabricante: Yamato
System: Automatic high-pressure steam sterilization | Operating temp. range (sterilization): 105~128℃ | Operating temp. range (drying): 150~180℃ | Max. pressure capacity: 0.2MPa | Safety device: Self-diagnostic f...
Tokio, JapónYamato SM501 Limited product for overseas
- Fabricante: Yamato
System: Automatic high-pressure steam sterilization | Operating temp. range (sterilization): 105~128℃ | Operating temp. range (drying): 150~180℃ | Max. pressure capacity: 0.2MPa | Safety device: Self-diagnostic f...
Tokio, JapónYamato SM311 Limited product for overseas
- Fabricante: Yamato
System: Automatic high-pressure steam sterilization | Operating temp. range (sterilization): 105~128℃ | Operating temp. range (drying): 150~180℃ | Max. pressure capacity: 0.2MPa | Safety device: Self-diagnostic f...
Tokio, JapónHORIBA Scientific PoliSpectra® RPR for HTS
- Fabricante: Horiba
Laser wavelength: Choose from 532 nm and 785 nm | Laser power for 532 nm: up to 150 mW | Laser power for 785 nm: up to 500 mW | Laser power adjustment: Software controlled | Deep cooled camera: < -25°C TE-cool...
Kioto, JapónYamato FO810
- Fabricante: Yamato
Operating temp. range: 100 to 1,150℃ | Temp. control accuracy: ±2.0℃(at 1,150℃) | Max. temp. reaching time: Approx. 80min. | Exterior material: Cold rolled steel plate with baked-on melamine resin finish | Intern...
Tokio, JapónYamato FO510
- Fabricante: Yamato
Operating temp. range: 100 to 1,150℃ | Temp. control accuracy: ±2.0℃(at 1,150℃) | Max. temp. reaching time: Approx. 80min. | Exterior material: Cold rolled steel plate with baked-on melamine resin finish | Intern...
Tokio, JapónYamato FO610
- Fabricante: Yamato
Operating temp. range: 100 to 1,150℃ | Temp. control accuracy: ±2.0℃(at 1,150℃) | Max. temp. reaching time: Approx. 80min. | Exterior material: Cold rolled steel plate with baked-on melamine resin finish | Intern...
Tokio, JapónYamato INC820
- Fabricante: Yamato
System (upper chamber): Natural convection, Air jacket | Operating temp. range(upper chamber): Room temp.+5℃~80℃ | Temp. adjustment accuracy (upper chamber): ±0.5℃(at 37℃) | Temp. distribution accuracy (upper cha...
Tokio, Japón