Building Filters
Trace Elemental Instruments XPLORER-V
- Fabricante: Trace Elemental Instruments
Configurations: • XPLORER-V TN/TS, Nitrogen and Sulfur analyzer • XPLORER-V TN, Nitrogen analyzer • XPLORER-V TS, Sulfur analyzer | Dimensions (w x h x d): 25...
Kioto, JapónHORIBA Advanced Techno Co., Ltd. HE-300R
- Fabricante: Horiba
Product name: Resistivity meter | Sensors in combination: 2-electrode method resistivity sensor (ERF-001 Series) of cell constant 0.01/cm | Temperature: Comparison to the accurate thermometer Both deviation and c...
Kioto, JapónHORIBA Advanced Techno Co., Ltd. HE-200R
- Fabricante: Horiba
Product name: Resistivity meter | Combined sensor: 2-electrode method resistivity sensor (ERF-001 Series) of cell constant 0.01/cm | Temperature: Comparison to the accurate thermometer Both deviation and coeffici...
Kioto, JapónHORIBA, Ltd. ENDA-5000
- Fabricante: Horiba
Repeatability: Within 0.5% of full scale/week (with optional range, or during O 2 measurement, ±1.0% of full scale/week) | Linearity (indicator error): ±1.0% of full scale | Zero drift: ±1.0% of full scale/week (...
Kioto, JapónHORIBA Advanced Techno Co., Ltd. HE-300C
- Fabricante: Horiba
Product name: Conductivity meter | Sensors in combination: 2-electrode method conductivity sensor ESH and FS Series sensor of cell constant 0.01/cm, 0.1/cm, or 1.0/cm | Temperature: 0.01℃ | Linearity: Within ±0.0...
Kioto, JapónHORIBA, Ltd. MESA-50K
- Fabricante: Horiba
Target application: RoHS, ELV, Halogen Free | Meas. elements: 13Al - 92U | Sample type: Solid, Liquid, Powder | X-ray irradiation size: 1.2mm, 3mm, 7mm (Automatic switching) | X-ray primary filter: 4 types (Autom...
Kioto, JapónHORIBA, Ltd. RP-1
- Fabricante: Horiba
Applicable case: Nikon/Canon/SMIF POD/HORIBA | Throughput: Simultaneously blows the glass and pellicle surfaces to remove particles approximately for 1 min. | Dimensions: 1190(D) x 1150(W) x 1520(H)mm
Kioto, JapónHORIBA Scientific Nanolog
- Fabricante: Horiba
Excitation sources: Choice of: 450 W xenon short-arc lamp housing with off axis ellipsoidal collector and optional pulsed xenon lamp enhancement (for time resolved phosphorescence) 75 W xenon PowerArcTM lamp...
Kioto, JapónHORIBA, Ltd. Partica LA-960V2
- Fabricante: Horiba
Measurement principle: Mie scattering and Fraunhofer diffraction | Measurement range: 100 nm - 5000 μm | Measurement time: Typical measurement takes 2 seconds or longer. | Measurement method: Circulation measurem...
Kioto, JapónPS-300S
- Fabricante: Horiba
Measurement principle: NDIR: Non-Dispersive Infrared | Linearity: ±2% full scale | Zero drift: ±2% full scale per day | Span drift: ±2% full scale per day | Sample gas flow rate: Max. 0.5 L/min | Display: 5.7-inc...
Kioto, JapónHORIBA Scientific Fluorolog-QM
- Fabricante: Horiba
Signal-to-noise ratio: (>35,000:1 FSD) | Data acquisition rate: 1,000,000 points/sec. to 1 point/1000 sec. | Inputs: 4 photon counting (TTL); 4 analog (+/- 10 volts); 1 analog reference channel (+/- 10 volts);...
Kioto, JapónHORIBA Advanced Techno Co., Ltd. HE-300R
- Fabricante: Horiba
Product name: Resistivity meter | Sensors in combination: 2-electrode method resistivity sensor (ERF-001 Series) of cell constant 0.01/cm | Temperature: Comparison to the accurate thermometer Both deviation and c...
Kioto, JapónHORIBA Advanced Techno Co., Ltd. HE-200R
- Fabricante: Horiba
Product name: Resistivity meter | Combined sensor: 2-electrode method resistivity sensor (ERF-001 Series) of cell constant 0.01/cm | Temperature: Comparison to the accurate thermometer Both deviation and coeffici...
Kioto, JapónOBS-ONE-XL (IRLAM)
- Fabricante: HORIBA, Ltd.
Measurement target: Light and heavy duty vehicle engine exhaust gas | Components and range: NH 3 0 - 1500 ppm N 2 O 0 - 1000 ppm | Measurement principle: Quantum cascade laser infrared spectroscopy (QCL-IR) | Sam...
Kioto, JapónHORIBA Scientific SLFA-2100/2800
- Fabricante: Horiba
Principle: X-ray fluorescent analysis | Sample: Sulfur content in petroleum products, such as heavy oil, naphtha, crude oil, etc. | Element: Sulfur | Range: 0 - 9,999% | Detection limit: 5 ppm or less | Accuracy:...
Kioto, Japón