Building Filters

DIGITAL MULTIMETER DT4253
Dc voltage range: 600.0 mV to 1000 V 5 ranges, Basic accuracy: ±0.3 % rdg. ±5 dgt. | Ac voltage range: 6.000 V to 1000 V, 4 ranges, Frequency characteristics: 40 Hz to 1 kHz Basic accuracy 40 - 500 Hz : ±0.9 % rd...
Nagano, Japón
DIGITAL MULTIMETER DT4256
Dc voltage range: 600.0 mV to 1000 V, 5 ranges Basic accuracy: ±0.3 % rdg. ±3 dgt. | Ac voltage range: 6.000 V to 1000 V, 4 ranges, Frequency characteristics: 40 Hz to 1 kHz Basic accuracy 40 - 500 Hz : ±0.9 % rd...
Nagano, Japón
AC CLAMP METER CM3281
Ac current range: 42.00 to 2000 A, 3 ranges (50 Hz to 60 Hz, Average rectified), Basic accuracy 50-60 Hz: ±1.5% rdg. ±5 dgt. | Dc voltage range: 420.0 mV to 600 V, 5 ranges, Basic accuracy: ±1.0 % rdg. ±3 dgt. (...
Nagano, Japón
AC CLAMP METER CM3291
Ac current range: 42.00 to 2000 A, 3 ranges (40 Hz to 1 kHz, True RMS), Basic accuracy 45-66 Hz: ±1.5% rdg. ±5 dgt. | Dc voltage range: 420.0 mV to 600 V, 5 ranges, Basic accuracy: ±1.0 % rdg. ±3 dgt. (at 4.2 V ...
Nagano, Japón
HORIBA Scientific VU90 Spectrometer
- Fabricante: Horiba
Spectral coverage: 115 - 230 nm Full coverage on CCD: 115 - 320 nm (No order sorting filter available) | Spectral resolution: 0.5 nm with 22 μm pinhole, 0.75 nm with 40 μm pinhole | Spectral dipersion: 12 nm/mm; ...
Kioto, Japón
SENSOR DE TOPE ACTIVO 9272-05
Corriente nominal: 20 A AC, o 200 A AC (seleccionable) | Entrada máxima permitida: 50 A rms (en rango de 20 A), 300 A rms (en rango de 200 A) | Características de frecuencia: 1 Hz (±2 % rdg. ±0.1 % f.s.) a 100 kH...
Nagano, Japón
AC/DC CLAMP METER CM4373-50
Dc current range: 600.0 A/2000 A, Basic accuracy: ±1.3% rdg. ±0.3 A (600 A range) | Ac current range: 600.0 A/2000 A (10 Hz to 1 kHz, True RMS), Basic accuracy 45 - 66 Hz: ±1.3% rdg. ±0.3 A (at 600 A) | Crest fac...
Nagano, Japón
AC/DC CLAMP METER CM4371-50
Dc current range: 20.00 A/600.0 A, Basic accuracy: ±1.3% rdg. ±0.08 A (20 A range) | Ac current range: 20.00 A/600.0 A (10 Hz to 1 kHz, True RMS), Basic accuracy: 45-66 Hz: ±1.3% rdg. ±0.08 A (at 20 A) | Crest fa...
Nagano, Japón
GX-100
Product name: Modular Water Supply Quality Monitor | Measurement items: Turbidity, color, free residual chlorine, water pressure, pH, conductivity, water temperature (Flow rate can also be selected and displayed ...
Kioto, Japón
AC/DC CLAMP METER CM4375-50
Dc current range: 1000 A, (Max. display 999.9 A) , Basic accuracy: ±1.3% rdg. ±0.3 A (at 30.1 A - 999.9 A) | Ac current range: 1000 A (Max. display 999.9 A, 10 Hz to 1 kHz, True RMS), Basic accuracy 45-66 Hz: ±1...
Nagano, Japón
AC CLAMP METER CM4141-50
Ac current range: 60.00 A to 2000 A, 3 ranges (45 Hz to 1 kHz, True RMS), Basic accuracy 45-66 Hz: ±1.5% rdg. ±0.08 A (60 A range) | Crest factor: For the 60.00 A range: 2.5 (greater than 50.00 A and less than or...
Nagano, Japón
ADS EVO
- Fabricante: HORIBA, Ltd.
Driving functions: Standard drive traces (emissions, etc) ★Performance test mode Auto/Manual adjust (pedal and shift) Learning mode Warm up mode Constant speed mode Manual mode | Applicable vehicles: MT, AT, CVT,...
Kioto, Japón
LEAK CURRENT HiTESTER ST5541
Measurement methods: Measurement of voltage drop across body simulated resistance points, Calculation and display of current values, True rms measurement, Measurement unit floats relative to instrument ground. ...
Nagano, Japón
LEAK CURRENT HiTESTER ST5540
Measurement methods: Measurement of voltage drop across body simulated resistance points, Calculation and display of current values, True rms measurement, Measurement unit floats relative to instrument ground....
Nagano, Japón
RESISTANCE METER RM3545A
resistance range (13 ranges): [Range, Maximum display value, Resolutions, Testing current (Measurement current) ] 1000 μΩ: 1200.000 μΩ, 1 nΩ, 1 A 10 mΩ: 12.000 00 mΩ, 10 nΩ, 1 A 100 mΩ: 120.000 0 mΩ, 100 nΩ, 1 A...