PTFM-ONE-DT
- Fabricante: HORIBA UK Limited
900°c exhaust gas limit: Allows the freedom to test engines under extreme conditions without worrying if the flow meter can handle those temperatures | -1.25kpa to +7.5kpa sensor range: Shows both positive flow &...
Kioto, JapónHORIBA Advanced Techno Co., Ltd. HE-200H
- Fabricante: Horiba
Product name: Conductivity meter | Sensors in combination: 4-electrode method conductivity sensor (FES Series) of cell constant 0.1/cm, or 1.0/cm | Display range: 0.0 to 220.0 | Temperature: 0.01℃ | Nacl: 0.0% to...
Kioto, JapónHORIBA Scientific VU111
- Fabricante: Horiba
Spectral coverage: Deep UV & UV | Minimum resolution: 1st optimization: 0.3 nm @ 312 nm 2nd optimization: 0.3 nm @ 223 nm | Average resolution from 220 nm up to 330 nm: 1st optimization: from 220 nm up to 330...
Kioto, JapónHORIBA, Ltd. VA-5000 / VA-5000WM Series
- Fabricante: Horiba
Communication: Ethernet (ModbusTM/TCP) | Output: Maximum 16ch isolated, Maximum voltage DC 30 V, Maximum current 1A Minimum voltage DC 0.1 V, Minimum current 0.1 mA | Sample condition: Ambient temperature, dust f...
Kioto, JapónHORIBA Advanced Techno Co., Ltd. HE-200C
- Fabricante: Horiba
Product name: Conductivity meter | Sensors in combination: 2-electrode method conductivity sensor ESH, ESD, ESL, and FS Series sensor of cell constant 0.01/cm,0.1/cm, or 1.0/cm | Temperature: 0.01℃ | Linearity: W...
Kioto, JapónYamato GAS410
- Fabricante: Yamato
- Modelo: GAS410
Solvent recovery system: Capacitor + freezer | Circulating gas: N2 gas (sealed circulation when connected to ADL311SA or GB-210A) | Circulating volume flow: 0.12 to 0.65m3/min | Compressor (for spraying): Linear ...
Tokio, JapónUV500 ATEX
Sample flow: Recommended : 0 - 5 L/MIN 0 – 0.5 l/min for NH4 or H2S | Sample pressure: 0 - 4 Bar (0 - 1 Bar with sampling peristaltic pump) 0 - 0.5 Bar for NH4 or H2S | Sample temperature: 0 °C to 80 °C 0 - 30 °C...
Kioto, JapónYamato CTW812
- Fabricante: Yamato
System: Integrated type, Water cooled electronic system, External open circulation | Operating temperature range: -10oC to +70oC | Temp. adjustment accuracy: ±0.1℃ | Cooling capacity: 250 kcal/h (291W) | Performa...
Tokio, JapónYamato CTA412S
- Fabricante: Yamato
System: Separated type, Air cooled electronic system, External open circulation | Operating temperature range: 0 to +70℃ | Temp. adjustment accuracy: ±0.1℃ | Cooling capacity: 83 kcal/h (97W) | Performance pump c...
Tokio, JapónYamato CTA402S
- Fabricante: Yamato
System: Separated type, Air cooled electronic system, External open circulation | Operating temperature range: 0 to +70℃ | Temp. adjustment accuracy: ±0.1℃ | Cooling capacity: 83 kcal/h (97W) | Performance pump c...
Tokio, JapónHORIBA STEC, Co., Ltd. MV-2000
- Fabricante: Horiba
Liquid material: All liquids except those corrosive to stainless steel(ex. HCl, HF) | Setting temperature: By vaporization conditions(Control Valve : Max 140 ˚C Vaporizer : Max 200 ˚C) | Leak integrity: ≤ 1 × 10-...
Kioto, JapónYamato CTW802S
- Fabricante: Yamato
System: Integrated type, Water cooled electronic system, External open circulation | Operating temperature range: -10oC to +70oC | Temp. adjustment accuracy: ±0.1℃ | Cooling capacity: 250 kcal/h (291W) | Performa...
Tokio, JapónYamato CTW402S
- Fabricante: Yamato
System: Separated type, Water cooled electronic system, External open circulation | Operating temperature range: -10oC to +70oC | Temp. adjustment accuracy: ±0.1℃ | Cooling capacity: 126 kcal/h (147W) | Performan...
Tokio, JapónYamato CTA812S
- Fabricante: Yamato
System: Separated type, Air cooled electronic system, External open circulation | Operating temperature range: 0 to +70℃ | Temp. adjustment accuracy: ±0.1℃ | Cooling capacity: 163 kcal/h (189W) | Performance pump...
Tokio, JapónYamato CTA812
- Fabricante: Yamato
System: Integrated type, Air cooled electronic system, External open circulation | Operating temperature range: 0 to +70℃ | Temp. adjustment accuracy: ±0.1℃ | Cooling capacity: 163 kcal/h (189W) | Performance pum...
Tokio, Japón