Building Filters
HyFQ-2000 Series
- Fabricante: HORIBA Europe GmbH
Basement accuracy mass flow sensor: ≤ 0.35 %MV | Fuel inlet pressure: 40 bar | Fuel outlet to engine pressure: up to 25 bar | Ambient/media temperature [°c]: Main Unit: +5 ... +40 DUT Unit: -2...
Kioto, JapónYamato SM530 Limited product for overseas
- Fabricante: Yamato
System: Automatic high-pressure steam sterilization | Operating temp. range (sterilization): 105~135℃ | Operating temp. range (drying): 135~150℃ | Max. pressure capacity: 0.255MPa | Operable ambient temp.: 5~35℃ ...
Tokio, JapónYamato SM820 Limited product for overseas
- Fabricante: Yamato
System: Automatic high-pressure steam sterilization | Operating temp. range (sterilization): 105~135℃ | Operating temp. range (drying): 135~150℃ | Max. pressure capacity: 0.255MPa | Operable ambient temp.: 5~35℃ ...
Tokio, JapónYamato SM210 Limited product for overseas
- Fabricante: Yamato
System: Automatic high-pressure steam sterilization | Operating temp. range (sterilization): 105~123℃ | Operating temp. range (drying): 150~180℃ | Max. pressure capacity: 0.18MPa | Safety device: Self-diagnostic ...
Tokio, JapónYamato SM520 Limited product for overseas
- Fabricante: Yamato
System: Automatic high-pressure steam sterilization | Operating temp. range (sterilization): 105~135℃ | Operating temp. range (drying): 135~150℃ | Max. pressure capacity: 0.255MPa | Operable ambient temp.: 5~35℃ ...
Tokio, JapónYamato SM511 Limited product for overseas
- Fabricante: Yamato
System: Automatic high-pressure steam sterilization | Operating temp. range (sterilization): 105~128℃ | Operating temp. range (drying): 150~180℃ | Max. pressure capacity: 0.2MPa | Safety device: Self-diagnostic f...
Tokio, JapónYamato SM501 Limited product for overseas
- Fabricante: Yamato
System: Automatic high-pressure steam sterilization | Operating temp. range (sterilization): 105~128℃ | Operating temp. range (drying): 150~180℃ | Max. pressure capacity: 0.2MPa | Safety device: Self-diagnostic f...
Tokio, JapónYamato SM311 Limited product for overseas
- Fabricante: Yamato
System: Automatic high-pressure steam sterilization | Operating temp. range (sterilization): 105~128℃ | Operating temp. range (drying): 150~180℃ | Max. pressure capacity: 0.2MPa | Safety device: Self-diagnostic f...
Tokio, JapónYamato SM830 Limited product for overseas
- Fabricante: Yamato
System: Automatic high-pressure steam sterilization | Operating temp. range (sterilization): 105~135℃ | Operating temp. range (drying): 135~150℃ | Max. pressure capacity: 0.255MPa | Operable ambient temp.: 5~35℃ ...
Tokio, JapónYamato SM301 Limited product for overseas
- Fabricante: Yamato
System: Automatic high-pressure steam sterilization | Operating temp. range (sterilization): 105~128℃ | Operating temp. range (drying): 150~180℃ | Max. pressure capacity: 0.2MPa | Safety device: Self-diagnostic f...
Tokio, JapónHORIBA Advanced Techno Co., Ltd. Finesse Solutions, LLC HE-960CW
- Fabricante: Horiba
Product name: Industrial 2-channel conductivity meter | Measurement method: Electrode type (2-electrode method) | Sensor input: 2 channels (for concurrent measurement with sensors isolated each other) | Cell cons...
Kioto, JapónHORIBA Advanced Techno Co., Ltd. HE-480H
- Fabricante: Horiba
Product name: Industrial conductivity meter | Measurement method: Electrode type (4-electrode method) | Cell constant: 1.0/cm | Seawater salinity conversion value (%): 0.00 to 4.00 | Nacl salinity conversion valu...
Kioto, JapónYamato BO601
- Fabricante: Yamato
Operating temp. range: Room temp. +5 to 180°C | Temp. control accuracy: ±0.3℃ (at 100°C) | Temp. control system: PlD control by microprocessor | Temp. setting / display method: Digital setting by ▲/▼ keys | Opera...
Tokio, JapónYamato BM401
- Fabricante: Yamato
Operating temp. range: Room temp. +5~95°C | Temp. adjustment accuracy: ±0.3°C (at 60°C) | Temp. control system: PlD control by microprocessor | Temp. setting / display method: Digital setting by ▲/▼ keys | Additi...
Tokio, JapónHORIBA Advanced Techno Co., Ltd. HO-200
- Fabricante: Horiba
Product name: ORP meter | Combined sensor: ORP electrode | Temperature: 0.1℃ | Linearity: Within ±8 mA (output only) | Output type: Contact output with voltage (output of connected power supply voltage) | Load re...
Kioto, Japón