Building Filters
Yamato DP410
- Fabricante: Yamato
Method: Vacuum drying by decompressed chamber direct heating | Max. temp. reaching time: Approx. 80 min. | Interior material: Stainless steel | Exterior material: Cold rolled steel plate with baking coating | Doo...
Tokio, JapónYamato DP200
- Fabricante: Yamato
Method: Vacuum drying by decompressed chamber direct heating | Max. temp. reaching time: Approx. 60 min. | Interior material: Stainless steel | Exterior material: Cold rolled steel plate baking coating | Door: Si...
Tokio, JapónYamato DKN812
- Fabricante: Yamato
Circulation method: Forced air circulation | Operating temp. range: Room temp. +10°C to 210°C | Temp. adjustment accuracy: ±1℃(at 210℃) | Temp. distribution accuracy: ±2.5℃(at 210℃) | Max. temp. reaching time: Ap...
Tokio, JapónYamato DKN302
- Fabricante: Yamato
- Modelo: DKN-302
Circulation method: Forced air circulation | Operating temp. range: Room temp. +10°C to 260°C | Temp. adjustment accuracy: ±1℃(at 210℃) | Temp. distribution accuracy: ±2.5℃(at 210℃) | Max. temp. reaching time: Ap...
Tokio, JapónYamato DKN602
- Fabricante: Yamato
- Modelo: DKN602
Circulation method: Forced air circulation | Operating temp. range: Room temp. +10°C to 250°C | Temp. adjustment accuracy: ±1℃(at 210℃) | Temp. distribution accuracy: ±2.5℃(at 210℃) | Max. temp. reaching time: Ap...
Tokio, JapónYamato DKN612
- Fabricante: Yamato
Circulation method: Forced air circulation | Operating temp. range: Room temp. +10°C to 250°C | Temp. adjustment accuracy: ±1℃(at 210℃) | Temp. distribution accuracy: ±2.5℃(at 210℃) | Max. temp. reaching time: Ap...
Tokio, JapónYamato DKN912
- Fabricante: Yamato
- Modelo: DKN912
Circulation method: Forced air circulation | Operating temp. range: RT +10°C to 210°C | Temp. adjustment accuracy: ±1℃(at 210℃) | Temp. distribution accuracy: ±2.5℃(at 210℃) | Max. temp. reaching time: Approx. 60...
Tokio, JapónYamato DKN402
- Fabricante: Yamato
- Modelo: DKN402
Circulation method: Forced air circulation | Operating temp. range: Room temp. +10°C to 250°C | Temp. adjustment accuracy: ±1℃(at 210℃) | Temp. distribution accuracy: ±2.5℃(at 210℃) | Max. temp. reaching time: Ap...
Tokio, JapónYamato ADP301
- Fabricante: Yamato
Method: Vacuum drying by decompressed chamber direct heating | Operating temperature range: 40 to 240℃ | Operating pressure range: 101 to 0.1kPa(760 to 1 Torr) | Temp. control accuracy: ± 1 ℃ (at240 ℃ JTM K05) | ...
Tokio, JapónYamato ADP201
- Fabricante: Yamato
Method: Decompression & chamber direct heating | Operating temperature range: 40 to 240℃ | Operating pressure range: 101 to 0.1kPa(760 to 1 Torr) | Temp. control accuracy: ± 1 ℃ (at240 ℃ JTM K05) | Max. temp. rea...
Tokio, JapónYamato DR200
- Fabricante: Yamato
Method: Natural convection | Temp. control range: 300 to 700℃ | Temp. adjustment accuracy: ±5℃(at 700℃) | Temp. distribution accuracy: ±25℃(at 700℃) | Max. temp. reaching time: Approx. 70min. | Interior: Stainles...
Tokio, JapónYamato BT220
- Fabricante: Yamato
Operating temp. range: Room temp.+5 to 80 deg.C | Temp. adjustment accuracy: ±0.05 deg.C (at 40 deg.C) | Temp. distribution accuracy: ±0.1 deg.C (at 40 deg.C) | Temp. rising time: Approx. 40 min (from 23deg.C to ...
Tokio, JapónYamato ADL311S-A
- Fabricante: Yamato
Temp. adjusting unit setting range: 40 to 220°C (inlet temperature), 0 to 60°C (Outlet temperature) | Temperature adjusting accuracy: Inlet temperature±1°C | Drying air amount adjusting range: 0 to 0.7m3/min | Sp...
Tokio, JapónYamato GB210-B
- Fabricante: Yamato
Temp. adjusting range: 40 to 220°C (inlet temperature), 0 to °60(Outlet temperature) | Temperature adjusting accuracy: Inlet temperature ± 1°C | Spraying system: Two-way nozzle, Nozzle No. 1A as standard | Drying...
Tokio, JapónYamato WG1012
- Fabricante: Yamato
Water purifying method: Ion exchange→Distillation→Filtration | Sampled pure water method: Ion-exchanged water / distilled water | Distilled water production: Approximately 5L / h | Amount of distilled water colle...
Tokio, Japón