- Sheringham, Reino Unido
DP Medical xe-50 Motion 2 Camera control unit/light source
Image sensor: 1/3’’ CCD | Power supply: 100/240 VAC, 50-60 Hz | Fuses: 2 Fine fuses, 5×20 mm, delay acting 3,5 AH (l=1500A) | Power consumption: 15 VA | Video resolution: 470 lines | Sensivity: < 1 lux (1/1.4) | ...
Woodmansey, Reino UnidoFlow Rate Sensor FRS
Principio de funcionamiento: Térmico (MEMS) | Rango de caudal estándar: -200 a +200 StdL/min | Resolución de caudal estándar: 0,1 StdL/min | Exactitud de caudal estándar: Típicamente +/-1,75 % de la lectura Máxim...
Nottingham, Reino Unido- $891 USDLondres, Reino Unido
Huber Multi Flow Control Cube MID S462650, Unipump V MC 473422 Chiller Accessory UK
- Fabricante: Huber
Mpn: S462650, 473422
$10,400 USDAshton-under-Lyne, Reino UnidoC3AR | 3000KG
Water pressure required: 1 – 3.5 bar | Production per 24 running hours: 3000Kgs | Electrical supply: 415V 3ph + N + E | Electrical wiring: 5 cores 4 mm2 | Current rating: 20A | Circuit breaker: 32A | Machine size...
Grimsby, Reino UnidoC2AR | 2000KG
Water pressure required: 1 – 3.5 bar | Production per 24 running hours: 2000Kgs | Electrical supply: 415V — 3ph + N + E | Electrical wiring: 5 cores 4 mm2 | Current rating: 17A | Circuit breaker: 32A | Machine si...
Grimsby, Reino UnidoC1AR | 1000KG
Water pressure required: 1 – 3.5 bar | Production per 24 running hours: 1000Kgs | Electrical supply: 415V — 3ph + + N + E | Electrical wiring: 5 cores 2.5 mm2 | Current rating: 12A | Circuit breaker: 16A | Machin...
Grimsby, Reino UnidoF2.5AR | 2500KG
Production per 24 running hours: 2500Kgs | Power rating: 11kW | Electrical supply: 415V – 3ph + N + E | Current rating: 22A | Refrigerant: R448A | Refrigerant charge: 10Kgs | Gwp: 1387 | Co2 equivalent: 13.9T | N...
Grimsby, Reino UnidoF3AR | 3000KG
Production per 24 running hours: 3000Kgs | Power rating: 12kW | Electrical supply: 415V – 3ph + N + E | Current rating: 24A | Refrigerant: R448A | Refrigerant charge: 12Kgs | Gwp: 1387 | Co2 equivalent: 16.7T | N...
Grimsby, Reino UnidoF0.6AR | 600KG
Production per 24 running hours: 600KG | Power rating: 5kW | Electrical supply: 415V – 3ph + N + E | Current rating: 10A | Refrigerant: R448A | Refrigerant charge: 3.5Kgs | Gwp: 1387 | Co2 equivalent: 4.9T | Net ...
Grimsby, Reino UnidoC2.5AR | 2500KG
Water pressure required: 1 – 3.5 bar | Production per 24 running hours: 2500Kgs | Electrical supply: 415V 3ph + N + E | Electrical wiring: 5 cores 4 mm2 | Current rating: 20A | Circuit breaker: 32A | Machine size...
Grimsby, Reino UnidoF1.5AR | 1500kg
Production per 24 running hours: 1500Kgs | Power rating: 8kW | Electrical supply: 415V – 3ph + N + E | Current rating: 16A | Refrigerant: R448A | Refrigerant charge: 5Kgs | Gwp: 1387 | Co2 equivalent: 7T | Net we...
Grimsby, Reino UnidoF2AR | 2000KG
Production per 24 running hours: 2000Kgs | Power rating: 8.5kW | Electrical supply: 415V – 3ph + N + E | Current rating: 17A | Refrigerant: R448A | Refrigerant charge: 8Kgs | Gwp: 1387 | Co2 equivalent: 11.1T | N...
Grimsby, Reino UnidoC5AR | 5000KG
Water pressure required: 1 – 3.5 bar | Production per 24 running hours: 5000Kgs | Electrical supply: 415V 3ph + N + E | Electrical wiring: 5 cores 4 mm2 | Current rating: 20A | Circuit breaker: 32A | Machine size...