Building Filters
HORIBA Advanced Techno Co., Ltd. HE-960RW
- Fabricante: Horiba
Product name: Industrial 2-channel specific resistance meter | Measurement method: Electrode type (2-electrode method) | Sensor input: 2 channels (for concurrent measurement with sensors isolated each other) | Ce...
Kioto, JapónHORIBA Advanced Techno Co., Ltd. HE-480C
- Fabricante: Horiba
Product name: Industrial conductivity meter | Measurement method: Electrode type (2-electrode method) | Cell constant: 0.01/cm, 0.1/cm, or 1.0/cm | Temperature sensor specifications: Platinum resistance 1000 Ω/0℃...
Kioto, JapónHORIBA Advanced Techno Co., Ltd. HP-480
- Fabricante: Horiba
Product name: Industrial pH meter | Measuring range: 0 pH to 14 pH: 0.01 pH resolution. Temperature 0℃ to 100℃: 1℃ resolution (selectable display). | Transmission output: 4 mA to 20 mA DC: input/output isolated t...
Kioto, JapónHORIBA Advanced Techno Co., Ltd. HE-480R
- Fabricante: Horiba
Product name: industrial resistance meter | Measurement method: Electrode type (2-electrode method) | Cell constant: 0.01/cm | Temperature sensor specifications: Platinum resistance 1000 Ω/0℃ | Repeatability: Wit...
Kioto, JapónHORIBA Advanced Techno Co., Ltd. HE-200H
- Fabricante: Horiba
Product name: Conductivity meter | Sensors in combination: 4-electrode method conductivity sensor (FES Series) of cell constant 0.1/cm, or 1.0/cm | Display range: 0.0 to 220.0 | Temperature: 0.01℃ | Nacl: 0.0% to...
Kioto, JapónHORIBA Advanced Techno Co., Ltd. RA-30
- Fabricante: Horiba
Product name: Rotating electrode polarographic residual chlorine sensor | Sensor type: RA-30 | Temperature: 0.1℃ | Linearity: Within ±0.08 mA (limited to the current linearity) | Output type: Voltage contact outp...
Kioto, JapónHORIBA Advanced Techno Co., Ltd. HE-960HI
- Fabricante: Horiba
Product name: Conductivity meter | Measuring method: Four-electrode type | Cell constant: 0.1/cm | Temperature sensor specifications: Resistance thermometer bulb 1000 Ω/0℃ | Temperature: −30℃ to 160℃ | Naoh: 0% t...
Kioto, JapónANALOG MΩ HiTESTER 3490
- Fabricante: HIOKI E.E
Rated output voltage: 250 V DC | Effective maximum indicated value: 100 MΩ | Accuracy 1st effective measuring range: ±2 % of scale length 0.05 to 50 MΩ | Lower limit resistance: 0.25 MΩ | Overload protection: 660...
Nagano, JapónYamato CF800P
- Fabricante: Yamato
Circulation type: Closed circulation | Operating temp. range: −20℃〜 Room Temperature | Cooling capacity: 1050W (903Kcal/h) at 10℃, 910W (782Kcal/h) at 0℃, 670W (576Kcal/h) at −10℃ | Temp. control: Refrigerator ON...
Tokio, JapónHORIBA Advanced Techno Co., Ltd. Finesse Solutions, LLC HE-960CW
- Fabricante: Horiba
Product name: Industrial 2-channel conductivity meter | Measurement method: Electrode type (2-electrode method) | Sensor input: 2 channels (for concurrent measurement with sensors isolated each other) | Cell cons...
Kioto, JapónYamato CF800
- Fabricante: Yamato
- Modelo: CF800
Circulation type: Closed circulation | Operational ambient temperature: 5 to 35°C | Operating temp. range: -20°C to Room temperature | Cooling capacity: 1050W (830Kcal/h) at liquid temp. 10oC, 910W (780Kcal/h) at...
Tokio, JapónYamato CF301
- Fabricante: Yamato
Circulation type: Closed circulation | Operational ambient temperature: 5 to 35°C | Operating temp. range: -20°C to Room temperature | Cooling capacity: 450W (385Kcal/h) at liquid temp. 10oC, 360W (380Kcal/h) at ...
Tokio, JapónYamato DKG810V
- Fabricante: Yamato
Method: Forced convection | Operating temperature range: Room temp. +30°C to 260°C | Temperature adjustment accuracy: ±0.5℃ | Temperature distribution accuracy: ±2℃(at 200℃)、±2.5℃(at 260℃) | Time to attain max. t...
Tokio, JapónYamato DKG810
- Fabricante: Yamato
Method: Forced convection | Operating temperature range: Room temp. +30°C to 260°C | Temperature adjustment accuracy: ±0.5℃ | Temperature distribution accuracy: ±2℃(at 200℃)、±2.5℃(at 260℃) | Time to attain max. t...
Tokio, JapónYamato DKG650V
- Fabricante: Yamato
Method: Forced convection | Operating temperature range: Room temp. +30°C to 260°C | Temperature adjustment accuracy: ±0.5℃ | Temperature distribution accuracy: ±2℃(at 200℃)、±2.5℃(at 260℃) | Time to attain max. t...
Tokio, Japón