Building Filters

Yamato DFS810
- Fabricante: Yamato
Method: Forced convection and ventilation | Operating temperature range: Room temp.+15~260℃ | Max. temp. reaching time: Approx. 40 min.(at 260℃) | Temperature adjustment accuracy: ±0.2℃(at 260℃) | Temperature dis...
Tokio, Japón
Yamato DFS710
- Fabricante: Yamato
Method: Forced convection and ventilation | Operating temperature range: Room temp.+15~260℃ | Max. temp. reaching time: Approx. 40 min.(at 260℃) | Temperature adjustment accuracy: ±0.2℃(at 260℃) | Temperature dis...
Tokio, Japón
Yamato SI402
- Fabricante: Yamato
Circulation method: Natural convection (for laboratory use only) | Operating temp. range: Room temp. +5~260°C | Temp. adjustment accuracy: JTM K05 ±1°C (at 260°C) | Temp. distribution accuracy: JTM K05 ±6°C (at 2...
Tokio, Japón
Yamato DKM300
- Fabricante: Yamato
Circulation method: Forced air circulation | Operating temperature range: Room temp. +10~260°C | Temp. control accuracy: ±1°C (at 210°C) | Temp. distribution accuracy: ±2.5℃(at 210℃) | Max. temp. reaching time: A...
Tokio, Japón
Yamato DKM600
- Fabricante: Yamato
Circulation method: Forced air circulation | Operating temperature range: Room temp. +10~260°C | Temp. control accuracy: ±1°C (at 210°C) | Temp. distribution accuracy: ±2.5℃(at 210℃) | Max. temp. reaching time: A...
Tokio, Japón
Yamato SI601
- Fabricante: Yamato
Circulation method: Natural convection | Operating temp. range: Room temp. +5~260°C | Temp. adjustment accuracy: 2°C (at 260°C) | Temp. distribution accuracy: 20°C (at 260°C) | Max. temp. reaching time: Approx. 7...
Tokio, Japón
Yamato DKM400
- Fabricante: Yamato
Circulation method: Forced air circulation | Operating temperature range: Room temp. +10~260°C | Temp. control accuracy: ±1°C (at 210°C) | Temp. distribution accuracy: ±2.5℃(at 210℃) | Max. temp. reaching time: A...
Tokio, Japón
Yamato SI401
- Fabricante: Yamato
Circulation method: Natural convection | Operating temp. range: Room temp. +5~260°C | Temp. adjustment accuracy: 2°C (at 260°C) | Temp. distribution accuracy: 20°C (at 260°C) | Max. temp. reaching time: Approx. 7...
Tokio, Japón
Yamato DKN812
- Fabricante: Yamato
Circulation method: Forced air circulation | Operating temp. range: Room temp. +10°C to 210°C | Temp. adjustment accuracy: ±1℃(at 210℃) | Temp. distribution accuracy: ±2.5℃(at 210℃) | Max. temp. reaching time: Ap...
Tokio, Japón
Yamato WG252
- Fabricante: Yamato
Water purifying method: Ion exchange → distillation → filtration | Sampled pure water method: Ion-exchanged water / distilled water | Distilled water production: About 1.5L / h | Amount of distilled water collect...
Tokio, Japón
Yamato DVS403
- Fabricante: Yamato
Method: Natural gravity convection | Operating temp. range: Room temp.+5~260℃ | Temp. control accuracy: ±1℃(at 260℃) | Temp. distribution accuracy: ±5℃(at 260℃) | Max. temp. reaching time: Approx. 75 min. | Inter...
Tokio, Japón
Yamato DVS603
- Fabricante: Yamato
Method: Natural gravity convection | Operating temp. range: Room temp.+5~260℃ | Temp. control accuracy: ±1℃(at 260℃) | Temp. distribution accuracy: ±5℃(at 260℃) | Max. temp. reaching time: Approx. 90 min. | Inter...
Tokio, Japón
Yamato DTS830
- Fabricante: Yamato
Method: Forced convection | Operating temperature range: Room temp. +30 to 360°C | Temp. control accuracy (jtm k05): ± 0.5°C (at 360°C) | Temp. fluctuation (jis): 1.0°C (at 360°C) | Temperature distribution accur...
Tokio, Japón
Yamato DKN912
- Fabricante: Yamato
- Modelo: DKN912
Circulation method: Forced air circulation | Operating temp. range: RT +10°C to 210°C | Temp. adjustment accuracy: ±1℃(at 210℃) | Temp. distribution accuracy: ±2.5℃(at 210℃) | Max. temp. reaching time: Approx. 60...
Tokio, Japón
Yamato DKN402
- Fabricante: Yamato
- Modelo: DKN402
Circulation method: Forced air circulation | Operating temp. range: Room temp. +10°C to 250°C | Temp. adjustment accuracy: ±1℃(at 210℃) | Temp. distribution accuracy: ±2.5℃(at 210℃) | Max. temp. reaching time: Ap...
Tokio, Japón