Yamato BLG200
- Fabricante: Yamato
System: Stirring cooler 80W, with helium refrigerant (not Freon) | Temp. control range: -40°C to 0°C (at ambient temp. of 23°C ± 5°C) | Temp. control accuracy: ±0.3°C (the cooling bath temp. in the stable state) ...
Tokio, JapónCHEMICAL IMPEDANCE ANALYZER IM3590
Measurement modes: LCR mode, Continuous measurement mode (LCR mode / Analyzer mode), Analyzer mode (Sweeps with measurement frequency and measurement level, temperature characteristics, equivalent circuit analysi...
Nagano, JapónPOWER ANALYZER PW6001
Measurement line type: Single-phase 2-wire, single-phase 3-wire, three-phase 3-wire, three-phase 4-wire | Number of input channels: Max. 6 channels; each input unit provides 1 channel for simultaneous voltage and...
Nagano, JapónYamato DNE650
- Fabricante: Yamato
Method: Forced air circulation | Operating temperature range: Room temp. +10°C to 260°C | Temperature adjustment accuracy: ±0.2℃(at 260℃) | Temperature distribution accuracy: ±2.0℃(at 260℃) | Time to attain max. ...
Tokio, JapónAC FLEXIBLE CURRENT SENSOR CT9667
Rated input current: 5000 A AC/ 500 A AC | Max. allowable input: 10000 A continuous (45 to 66 Hz, requires derating at frequency) | Bandwidth: 10 Hz to 20 kHz (±3dB) | Amplitude and phase accuracy: ±2 % rdg. ±0.3...
Nagano, JapónPOWER METER PW3335
Measurement lines: Single-phase/ two-wires | Measurement items: Voltage, current, active power, apparent power, reactive power, power factor, phase angle, frequency, maximum current ratio, current integration, ac...
Nagano, JapónYamato DNE670V
- Fabricante: Yamato
Method: Forced air circulation | Operating temperature range: Room temp. +10°C to 260°C | Temperature adjustment accuracy: ±0.2℃(at 260℃) | Temperature distribution accuracy: ±2.0℃(at 260℃) | Time to attain max. ...
Tokio, JapónYamato DNE850V
- Fabricante: Yamato
Method: Forced air circulation | Operating temperature range: Room temp. +10°C to 260°C | Temperature adjustment accuracy: ±0.2℃(at 260℃) | Temperature distribution accuracy: ±2.0℃(at 260℃) | Time to attain max. ...
Tokio, JapónYamato DNE850
- Fabricante: Yamato
Method: Forced air circulation | Operating temperature range: Room temp. +10°C to 260°C | Temperature adjustment accuracy: ±0.2℃(at 260℃) | Temperature distribution accuracy: ±2.0℃(at 260℃) | Time to attain max. ...
Tokio, JapónYamato DNE670
- Fabricante: Yamato
Method: Forced air circulation | Operating temperature range: Room temp. +10°C to 260°C | Temperature adjustment accuracy: ±0.2℃(at 260℃) | Temperature distribution accuracy: ±2.0℃(at 260℃) | Time to attain max. ...
Tokio, JapónYamato DNE650V
- Fabricante: Yamato
Method: Forced air circulation | Operating temperature range: Room temp. +10°C to 260°C | Temperature adjustment accuracy: ±0.2℃(at 260℃) | Temperature distribution accuracy: ±2.0℃(at 260℃) | Time to attain max. ...
Tokio, JapónAC LEAKAGE CLAMP METER CM4003 (Output and external power supply function)
Ac current range: 6.000 mA, 60.00 mA, 600.0 mA, 6.000 A, 60.00 A, 200.0 A, 6 ranges, True RMS Basic accuracy 45 Hz - 400 Hz: ±1.0% rdg ±5 dgt (6.000 mA to 6.000 A), ±1.5% rdg ±5 dgt (60.00 A, 200.0 A) Basic accur...
Nagano, JapónAC LEAKAGE CLAMP METER CM4001
Ac current range: 60.00 mA/ 600.0 mA/ 6.000 A/ 60.00 A/ 600.0 A, 5 ranges (40 Hz to 1 kHz, True RMS) Basic accuracy (45-66 Hz): ±1.5% rdg ±5 dgt (60.00 mA to 6.000 A), ±2.5% rdg ±5 dgt (60.00 A to 600.0 A) Guaran...
Nagano, JapónAC LEAKAGE CLAMP METER CM4002
Ac current range: 6.000 mA, 60.00 mA, 600.0 mA, 6.000 A, 60.00 A, 200.0 A, 6 ranges, True RMS Basic accuracy 45 Hz - 400 Hz: ±1.0% rdg ±5 dgt (6.000 mA to 6.000 A), ±1.5% rdg ±5 dgt (60.00 A, 200.0 A) Basic accur...
Nagano, JapónSWITCH MAINFRAME SW1001
Slots: 3 slots | Supported modules: MULTIPLEXER MODULE SW9001 (2-wire/4-wire) MULTIPLEXER MODULE SW9002 (4-terminal pair) | Connectible instruments: Max. 2 units 2-wire × 1 + 4-wire × 1, or 2-wire × 1 + 4-termina...