LZCK-55 clamp outdoor waterproof split core current transformer
Standards: IEC60044-1; IEC 61869-2; NTC 2205; GB1208-2006; GB/T20840.2; ANSI/IEEE C57.13 | Accuracy class: 0.5S, 0.5% , 1% , 3% | Range of primary rated current: 100-1000A | Range of rated load: ≤10VA | Rated fre...
Pekín, Chinaq20b 100a high performance split core ac current clamp on cts
Ratio: 10001, 20001 or 25001 (customized) | Accuracy class: 0.1%, 0.2%, 0.5% | Primary current: 0-5A, 0-10A, 0-20A, 0-100A, 0-200A AC | Secondary current: 0-100mA AC, 0-200mA AC (customized) | Max. cont. input cu...
Pekín, ChinaXQ20 high precision 200A AC mini clamp on split core current sensor
Ratio: Ratio 10001, 20001 or 25001 (customized) | Accuracy class: 0.1%, 0.2% | Primary current: 0-10A AC, 0-20A AC, 0-100A AC, 0-200A AC | Secondary current: 0-100mA AC, 0-200mA AC (customized) | Max. cont. input...
Pekín, ChinaLZCK-80 Ip68 outdoor waterproof high accuracy 0.5s split core current transformer
Standards: IEC60044-1; IEC 61869-2; NTC 2205; GB1208-2006; GB/T20840.2; ANSI/IEEE C57.13 | Accuracy class: 0.5S, 0.5% , 1% , 3% (IEC61869 standard) | Range of primary rated current: 100-2000A | Range of rated loa...
Pekín, ChinaGF2015 Wireless primary current recorder meter
Recording ammeter kit: 3 wireless current sensors (GF2015A, GF2015B, GF2015C) 433 HHT (handheld terminal) or 433M wireless data reader (GF2015R) PC-LinkSoftware software (GF2015S) Carrying case | Data recording i...
Pekín, ChinaGF2018 high voltage wireless primary current sensor
Recording ammeter kit: 3 wireless current sensors (GF2018A, GF2018B, GF2018C) 433 HHT (handheld terminal) or 433M wireless data reader (GF2018R) PC-LinkSoftware software (GF2018S) Carrying case | Data recording i...
Pekín, ChinaQ8 5a high performance permalloy clamp on ac current sensor
Ratio: 20001 or 10001 (customized) | Accuracy class: 0.2%, 0.5% | Phase shift: <15' | Primary current: 0-5A, 0-10A AC | Secondary current: 0-5mA, 0-10mA AC (customized) | Secondary voltage: 0-0.1V AC, 0-0.5V AC, ...
Pekín, ChinaFUD-P4/Q4 3P4W active and reactive power transducer
- Fabricante: BEIJING GFUVE ELECTRONICS
Ac input: V0 57V, V1 100V, V2 220V, V3 270V, V4 400V, A1 0-1A, A2 0-5A. | Power supply: P1 AC110V±10% , P2 AC220V±15% , P3 AC110V-330V. | Dc output: O1 0-20mA, O2 0-±20mA, O3 4-20mA, O4 4-12-20mA, O5 0-1V, O6 0-±...
Pekín, ChinaD20 2MHz frequency bandwidth 200A AC/DC current probe
Ratio: 10001 or 20001 (customized) | Accuracy class: 0.2% , 0.5% , 1% , 2% | Primary current: 0-100A or 0-200A AC/DC | Signal output: 10mV/A or 1mV/A | Secondary voltage: 0-1V or 0-2V AC/DC | Max. cont. input cur...
Pekín, ChinaQ8A-1 high precision nickel metal core ac clamp on current probe
Ratio: 10001, 20001 or 25001 (customized) | Accuracy class: 0.1%, 0.2% | Primary current: 0-5A AC, 0-10A AC, 0-20A AC | Secondary current: 0-2.5mA, 0-5mA, 0-10mA, 0-20mA AC (customized) | Secondary voltage: 0-50m...
Pekín, Chinalzck-120 outdoor 120mm window ip67 split core ct transformer
Standards: iec60044-1; iec 61869-2; ntc 2205; gb1208-2006; gb/t20840.1&2; ansi/ieee c57.13 | Accuracy class: 0.5S, 0.5% , 1% , 3% (IEC61869 standard) | Range of primary rated current: 300-3000A | Range of rated l...
Pekín, ChinaFUD-P3/Q3 3P3W active and reactive power transducer
- Fabricante: BEIJING GFUVE ELECTRONICS
Ac input: V1 100V, V2 0-220V, V3 270V, V4 400V A1 0-1A, A2 0-5A. | Power supply: P1 AC110V±10% , P2 AC220V±15% , P3 AC110V-330V. | Dc output: O1 0-20mA, O2 0-±20mA, O3 4-20mA, O4 4-12-20mA, O5 0-1V, O6 0-±1V, O7 ...
Pekín, ChinaFUD-I/U single phase 4-20ma AC voltage current transducer
- Fabricante: BEIJING GFUVE ELECTRONICS
Ac input: A1 0-1A, A2 0-5A, A3 0-10A.V0 0-70V, V1 0-120V, V2 0-250V,V3 0-300V, V4 0-450V, V5 0-500V. | Power supply: P1 AC 110V±10% , P2 AC 220V±15% , P3 AC 110V-330V. | Dc output: O1 0-5V, O2 1-5V, O3 0-20mA, O4...
Pekín, ChinaLMCK185-10 IP65 waterproof split core outdoor current transformer
Standards: IEC60044-1; IEC 61869-2; NTC 2205; GB1208-2006; GB/T20840.1 & 2; ANSI/IEEE C57.13 | Accuracy class: 0.5S, 0.5% , 1% , 3% (IEC61869 standard) | Range of primary rated current: 300-5000A | Range of rated...
Pekín, ChinaFUD-PF Power factor transducer
- Fabricante: BEIJING GFUVE ELECTRONICS
Ac input: V0 57V, V1 100V, V2 220V, V3 270V, V4 400V, V5 User defined; A1 1A, A2 5A | Power supply: P1 AC110V±10% , P2 AC220V±15% | Pf range: C1 0(C)-1-0(L), C2 0.5(C)-1-0.5(L), C3 0-1 | Dc output: O1 0-5V, O2 1-...