Building Filters
Yamato SI402
- Fabricante: Yamato
Circulation method: Natural convection (for laboratory use only) | Operating temp. range: Room temp. +5~260°C | Temp. adjustment accuracy: JTM K05 ±1°C (at 260°C) | Temp. distribution accuracy: JTM K05 ±6°C (at 2...
Tokio, JapónYamato CIW1100
- Fabricante: Yamato
Circulation method: External closed system circulation | Cooling method: Water-cooled type | Temperature control range: 0 - 80℃ (Operation of entire freezer) | Operating temperature range: 5 - 35℃ | Temp. adjustm...
Tokio, JapónLEAK CURRENT HiTESTER ST5540
Measurement methods: Measurement of voltage drop across body simulated resistance points, Calculation and display of current values, True rms measurement, Measurement unit floats relative to instrument ground....
Nagano, JapónCLAMP ON EARTH TESTER FT6380-50
- Fabricante: HIOKI E.E
Measurement principle: Instrument has two cores for voltage injection and current measurement. From the defined voltage and measured current, the total circuit loop resistance is calculated Note: For multi groun...
Nagano, JapónRESISTANCE METER RM3545A
resistance range (13 ranges): [Range, Maximum display value, Resolutions, Testing current (Measurement current) ] 1000 μΩ: 1200.000 μΩ, 1 nΩ, 1 A 10 mΩ: 12.000 00 mΩ, 10 nΩ, 1 A 100 mΩ: 120.000 0 mΩ, 100 nΩ, 1 A...
Nagano, JapónYamato IN604
- Fabricante: Yamato
System: Forced air convection | Operating temperature range: -10~50℃ | Temperature adjustment accuracy: ±0.3℃(when refrigerator is in continuous operation), ±1.0℃(when refrigerator is in cycle operation) | Temper...
Tokio, JapónYamato IQ822
- Fabricante: Yamato
System: Forced Convection | Operating temperature range: -10~+50℃ | Temperature adjustment accuracy: ±0.3℃(During continuous refrigeration for both upper and lower chamber) | Temperature distribution accoracy: ±1...
Tokio, JapónYamato IN804
- Fabricante: Yamato
- Modelo: IN804
System: Forced air convection | Operating temperature range: -10~50℃ | Temperature adjustment accuracy: ±0.3℃(when refrigerator is in continuous operation), ±1.0℃(when refrigerator is in cycle operation) | Temper...
Tokio, JapónYamato IN604W
- Fabricante: Yamato
System: Forced air convection | Operating temperature range: -10~50℃ | Temperature adjustment accuracy: ±0.3℃(when refrigerator is in continuous operation), ±1.0℃(when refrigerator is in cycle operation) | Temper...
Tokio, JapónYamato INE800
- Fabricante: Yamato
- Modelo: INE800
Safety device: Self-diagnostic functions(Temp. sensor error, Heater disconnection, SSR short-circuit, Main relay error, Automatic overheat prevention), Key-lock, Over current ELB, Overheat preventive device | She...
Tokio, JapónAC/DC CLAMP METER CM4371-50
Dc current range: 20.00 A/600.0 A, Basic accuracy: ±1.3% rdg. ±0.08 A (20 A range) | Ac current range: 20.00 A/600.0 A (10 Hz to 1 kHz, True RMS), Basic accuracy: 45-66 Hz: ±1.3% rdg. ±0.08 A (at 20 A) | Crest fa...
Nagano, JapónHORIBA Advanced Techno Co., Ltd. HO-300
- Fabricante: Horiba
Product name: ORP meter | Combined sensor: ORP electrode | Temperature: 0.1℃ | Linearity: Within ±0.08 mA (output only) | Load resistance: Max.: 600Ω (case of 24 V DC power supply)* 1 | Repeatability: Within ±0.0...
Kioto, JapónHORIBA Advanced Techno Co., Ltd. HD-300
- Fabricante: Horiba
Product name: Dissolved oxygen meter | Combined sensor: 5505, 5510 (A bipolar diaphragm type polarography sensor) | Combined probe: DO-1100 | Saturation degree: 1% | Temperature: 0.1℃ | Linearity: Within ±0.08 mA...
Kioto, JapónHORIBA Advanced Techno Co., Ltd. HE-960LF
- Fabricante: Horiba
Product name: Conductivity meter | Measurement method: Electrode type(2-electrode method) | Temperature specifications sensor: Platinum resistance 1000Ω/℃ | 0.0 to 200.0μs/cm: 0 to 2000μS/cm | 0 to 1000μs/cm: 0 t...
Kioto, JapónHORIBA Advanced Techno Co., Ltd. 1009
- Fabricante: Horiba
Product name: Fluoride ion electrode | Measurable range: 0 mg/L to 10000 mg/L (Display range: 0 mg/L to 11000 mg/L) | Temperature: 0.1℃ | Linearity: Within ±0.08 mA (output only) | Load resistance: Max. 600Ω (cas...