Building Filters
Roland V-02HD MKII Streaming Video Mixer
- Fabricante: Roland
Video processing: 4:4:4 (Y/Pb/Pr), 10-bit | Input 1--2: HDMI Type A x 2 | Program out: HDMI type A | Preview out: HDMI type A | 1920 x 1200/60 hz: Reduced blanking | Transition: CUT, MIX (DISSOLVE), WIPE (9 types...
$505 USDLondres, Reino UnidoPortables 9031M DO/Temperature Basis Portable Meter
- Fabricante: Jenco Instruments
Do range: 0.00 to 20.00 mg/L | Do resolution: 0.01 mg/L | Do accuracy: ±1.5% of reading or ±0.15 mg/L, whichever is greater | Do% saturation range: 0.0 to 200.0% | Do% saturation resolution: 0.1% | Do% saturation...
San Diego, CaliforniaPortables 9031B DO/Temperature Bluetooth Portable Meter
- Fabricante: Jenco Instruments
Do range: 0.00 to 20.00 mg/L | Do resolution: 0.01 mg/L | Do accuracy: ±1.5% of reading or ±0.15 mg/L, whichever is greater | Do% saturation range: 0.0 to 200.0% | Do% saturation resolution: 0.1% | Do% saturation...
San Diego, CaliforniaPortables 3011B Cond/TDS/Salt/Temperature Bluetooth Portable Meter
- Fabricante: Jenco Instruments
Conductivity range: 0.000 uS/cm to 400.0 mS/cm | Conductivity resolution: 0.001 μS/cm, 0.01 μS/cm, 0.1 μS/cm, 1 μS/cm, 0.01 mS/cm, 0.1 mS/cm | Conductivity accuracy: ±0.5% F.S. | Tds range: 0.000 mg/L to 400.0 g/...
San Diego, CaliforniaPortables 6011B/6011BEU pH/ORP/Temp Bluetooth Portable Meter
- Fabricante: Jenco Instruments
Ph range: -2.00 to 20.00 pH | Ph resolution: 0.01 pH | Ph accuracy: ±0.01 pH | Mv range: -2000 to 2000 mV | Mv resolution: 1 mV | Mv accuracy: ±0.1% F.S. | Temperature range: -10.0 to 120.0 °C (14.0 to 248.0 °F) ...
San Diego, CaliforniaPortables 9011B DO/Temperature Bluetooth Portable Meter
- Fabricante: Jenco Instruments
Do range: 0.00 to 50.00 mg/L | Do resolution: 0.01 mg/L | Do accuracy: ± 0.5%F.S(only meter), 0 to 20 mg/L, ± 2% of the reading or ±0.2 mg/L, whichever is greater, 20 to 50 mg/L, ± 6% of the reading | Do% saturat...
San Diego, CaliforniaPortables 6011M/6011EU pH/ORP/Temperature Basis Portable Meter
- Fabricante: Jenco Instruments
Ph range: -2.00 to 16.00 pH | Ph resolution: 0.01 pH | Ph accuracy: ±0.01 pH | Mv range: -1999 to 1999 mV | Mv resolution: 1 mV | Mv accuracy: ±0.1% F.S. | Temperature range: -10.0 to 120.0 °C | Temperature resol...
San Diego, CaliforniaDissolved Oxygen Probe
Measurement technique: Luminescent Optical Technology | Accuracy do: ± 0.1 mg/L | Accuracy temperature: ± 0.2 °C | Response time: 40 second to 90% (T-90) | Body material: Stainless Steel 316 body | Sensor protect...
Kioto, Japón1997 YTRON ZC 5,5 powder dissolver
- Fabricante: YTRON ZC
Categoría: Disolvente de polvo | Yom: 1997 | Número de serie: 9701181
Udenhout, Países BajosInlines DO3910
- Fabricante: Jenco Instruments
Do% saturation range: 0.0 to 199.9% | Do% saturation resolution: 0.01 % | Do% saturation accuracy: ±0.2% F.S. | Do calibration: 2 point calibration, manual | Current output: 4 ~ 20 mA | Type of electrode: Polarog...
San Diego, CaliforniaADSS Cool 360° Cooling Cryolipolysis Machine
- Fabricante: ADSS
- Modelo: FG660L-006
Delivery method: By Air, By DHL/TNT/FEDEX/UPS Express Door To Door, By Sea | Oem/odm: Having been in the industry for 19 years, all of our product lines can be fully customized to meet your specific needs at comp...
Pekín, ChinaDissolved Oxygen Probe Auto Cleaning
Measurement technique: Fluorescence Optical Technology | Accuracy: 1% of reading or 0.05 ppm, whichever is greater | Response time: 60 second to 90% (T-90) | Wetted material: Epoxy, polyurethane and PVC | Sensor ...
Kioto, JapónInlines 3951
- Fabricante: Jenco Instruments
Do range: 0.00 to 40.00 mg/L | Do resolution: 0.01 mg/L | Do accuracy: ±0.2% F.S. | Do% saturation range: 0.0 to 400.0 % | Do% saturation resolution: 0.1 % | Do% saturation accuracy: ±0.2% F.S. | Temperature rang...
San Diego, CaliforniaInlines 3921
Do range: 0.00 to 40.00 mg/L | Do resolution: 0.01 mg/L | Do accuracy: ±0.2 % F.S. | Do% saturation range: 0.0 to 400.0 % | Do% saturation resolution: 0.1 % | Do% saturation accuracy: ±0.2 % F.S. | Temperature ra...
San Diego, CaliforniaInlines 3931
- Fabricante: Jenco Instruments
Do range: 0.00 to 40.00 mg/L | Do resolution: 0.01 mg/L | Do accuracy: ±0.2 % F.S. | Do% saturation range: 0.0 to 400.0 % | Do% saturation resolution: 0.1 % | Do% saturation accuracy: ±0.2 % F.S. | Temperature ra...
San Diego, California